DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination  

Kwon, Ik-Soo (HVDC Electric Power Lab. Hanyang University)
Hwang, Jae-Sang (HVDC Electric Power Lab. Hanyang University)
Koo, Jae-Hong (HVDC Electric Power Lab. Hanyang University)
Sakamoto, Kuniaki (HVDC Electric Power Lab. Hanyang University)
Lee, Bang-Wook (HVDC Electric Power Lab. Hanyang University)
Publication Information
KEPCO Journal on Electric Power and Energy / v.1, no.1, 2015 , pp. 39-46 More about this Journal
Abstract
A outdoor termination installed at the outdoor substation is required to connect undergroud cables and overhead transmission lines. The joint box for AC transmission system is already developed and widely used to interconnect overhead and undergroud systems. But the development of the joint box for DC transmission system was only introduced from China and Japan, but theire developemnt staus and core technologies were not fully reported. In order to implement HVDC systems connecting ovehead transmission lines and undergroud cables, a outdoor termination should be developed, but the detailed specifications and information of this device were not reported. It is estimated that the development of the joint box for DC environment has some technical obstacles including insulating materials, electric field mitigation, thermal temperature rise, and space charge accumuations. Among this, the most important one is the DC elctrical insualtion design. Therefore, in order to investigate the DC elctrical insualton design of outdoor termination, the design of AC slip-on type outdoor termination is reffered, and DC electric field analysis performed to verify the possiblity of application of AC joint box into DC joint box. Especially for DC electric field analysis, temperature rise of insualting materials of a joint box was considered, because the conductivity of materials could be changed due to temperature rise. Furthermore, DC electric field analysis considering transinet state, and polarity reversal state were also investigated to verify which state is the most severe condition for the DC joint box. From the simualtion resulsts, it was shown that the value and the position of maximum electric field was obtained comparing AC state, DC state without temperaure rise, and DC state with temperaure rise. And it was confimred that severe DC electric field was observed considing temperaure rise. Finally, in order to reduce DC eletric field intensifation, different configuration of the joint box was applied and it was not possible to obtain satisfactory results. It means that the slight change of configuration of AC joint box was not the suitable soluton for DC joint box. It is essential to establish novel DC insulaton design skills and method for DC joint box to commercialze this product in the near future.
Keywords
Outdoor termination; End-box joint in air; DC electric field; electrical conductivity; thermial effect;
Citations & Related Records
연도 인용수 순위
  • Reference
1 F.H.Kreuger "Industrial High DC voltage", Delft University Press, 1995.
2 I. Beyer, P. H. F. Morshuis, "Conduction Current Measurements on Polycarbonates Subjected to Electrical and Thermal Stress", Proceedings CEDP, 2000, pp. 617-621.
3 G. C. Montanai, "The Electrical Degradation Threshold of Polyethylene Investigated by Space Charge and Conduction Current Measurements", IEEE Transaction on DEI, Vol. 7, No. 3, 2000, pp. 309-315.   DOI
4 B. Sanden, E. Udsrad, R. Hegerberg, "Space Charge Accumulation and Conduction Current in XLPE Insulation", DMMA, Conf Publ 430, 1996, pp. 368-37