• 제목/요약/키워드: DC Discharge

검색결과 373건 처리시간 0.024초

ADN Gate PDP의 DC 방전셀 방전특성 최적화 (Optimization on the Characteristics of DC Discharge Cell in the AND Gate PDPs)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.34-39
    • /
    • 2004
  • 본 연구에서는 새로 고안된 AND gate PDP의 AND gate를 구성하는 4개의 DC 방전셀에 대한 상호간의 영향을 방전특성 측면에서 규명하였다. 이 4개의 방전셀들의 방전개시 전압은 인접한 방전셀의 방전에서 발생하는 공간전하와 깊은 관련이 있다는 것을 알았다. 실험 결과 각 방전셀의 최적화된 방전 전압을 결정할 수 있었으며 PDP의 address 방전에 이용되는 floating 방전을 도와주는 priming 방전의 동작마진을 얻기가 어렵다는 것을 정석적으로 알 수 있었다.

Flow Actuation by DC Surface Discharge Plasma Actuator in Different Discharge Modes

  • Kim, Yeon-Sung;Shin, Jichul
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제16권3호
    • /
    • pp.339-346
    • /
    • 2015
  • Aerodynamic flow control phenomena were investigated with a low-current DC surface discharge plasma actuator. The plasma actuator was found to operate in three different discharge modes with similar discharge currents of about 1 mA or less. Stable continuous DC discharge without audible noise was obtained at higher ballast resistances and lower discharge currents. However, even with continuous DC power input, a low-frequency self-pulsed discharge was obtained at lower ballast resistances, and a high-frequency self-pulsed discharge was obtained at higher set-point currents and higher ballast resistances, both with audible noise. The Schlieren image reveals that the low-frequency self-pulsed mode produces a synthetic jet-like flow implying that a gas heating effect plays a role, even though the discharge current is small. The high-frequency self-pulsed mode produces pulsed jets in a tangent direction, and the continuous DC mode produces a steady straight pressure wave. Particle image velocimetry (PIV) images reveal that the induced flow field by the low-frequency self-pulsed mode has flow propagating in the radial direction and centered between the electrodes. The high-frequency self-pulsed mode and continuous DC mode produce flow from the anode to the cathode. The perturbed region downstream of the cathode is larger in the high-frequency self-pulsed mode with similar maximum speeds.

AND Gate PDP의 Floating 방전특성에 관한 연구 (A Study on the Characteristics of Floating Discharge in the AND Gate PDP)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.22-27
    • /
    • 2004
  • 새로 제안된 기체방전 AND gate를 3전극 면방전 AC PDP에 적용하기 위하여 DC-AC floating 방전을 사용한 어드레스 방전 특성을 해석하였다. 실험결과 Y 전극을 floating 전극으로 한 floating 방전을 이용하여 어드레스 방전을 개시시킬 수 있었으며 표시방전을 유지시킬 수 있었다. 또한 floating 방전과 타이밍을 일치시켜 보조전극에 DC 프라이밍 방전을 일으켜 줌으로써 floating 방전 공간에 공간전하를 충분히 공급해 주어 그 결과 데이터 전압을 100(V)까지 낮출 수 있었다. 이 DC-AC floating 방전을 사용한 구동방식은 100(V)의 어드레스 동작마진을 얻을 수 있었다.

위상 천이 소프트 스위칭 PWM DC-DC 컨버터를 이용한 방전등 구동용 직류 전원장치 (DC Power Supply Driving Discharge Lamp Using PWM DC-DC Converter of Single- Phase Shift Soft Switching)

  • 이현우;정상화;권순걸;서기영
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.100-106
    • /
    • 2005
  • 일반적으로 자외선(UV)을 발생하기 위한 방전등 구동용 직류 전원장치는 하드 스위칭 모드로 동작되어지는 고주파 스위칭 DC-DC 컨버터가 사용되고 있다. 구체적으로 전원장치는 전자 노이즈 장해에 의한 전자 회로의 오동작이나 각 구성 소자의 발열의 문제 등이 시스템의 신뢰성을 저하시키는 원인이 되고 있다. 그러므로 본 논문에서는 소프트 스위칭 회로 기술을 사용한 고주파 링크 DC-DC 컨버터로서 먼저 구체적으로 1차측 위상 천이 PWM DC-DC 컨버터와 제안한 2차측 위상 천이 PWM DC-DC 컨버터를 조합하여 방전등 구동용 직류 전원장치를 제안하였다. 제안하는 방전등 구동용 직류 전원장치는 시뮬레이션과 실험을 통하여 그 타당성을 서술하였다.

방전논리게이트 플라즈마 디스플레이 패널의 직류방전 지연특성 (The Delay-Time Characteristics of DC Discharge in the Discharge Logic Gate Plasma Display Panel)

  • 염정덕;곽희로
    • 조명전기설비학회논문지
    • /
    • 제21권1호
    • /
    • pp.28-34
    • /
    • 2007
  • 본 연구에서는 새로 고안된 방전 논리 게이트 PDP의 논리 게이트 입력인 DC 방전특성에 대해 고찰하였다. 새로 고안된 방전 논리 게이트는 방전 경로에 따른 전극사이의 전위차를 제어하여 논리 출력을 유도한다. 실험결과 이 DC 방전들의 안정성을 위해 프라이밍 방전을 인가한 경우가 인가하지 않은 경우에 비해 방전지연시간이 1/3로 단축되며 방전개시전압은 1/2로 감소하였다. 또한 이 프라이밍 방전에서 발생한 공간전하는 방전종료 후 $30[{\mu}s]$ 정도까지 영향을 미친다. 그리고 시간적, 공간적 거리변화에 파라 공간전하가 DC 방전에 미치는 영향을 측정한 결과, 주 방전에서부터 시간적으로 멀어지는 것보다 공간적으로 멀어지는 것이 주 방전의 영향에서 쉽게 벗어날 수 있음을 알았다. 그러므로 각 주사전극 마다 방전 논리 게이트들을 독립적으로 동작시킬 수 있다는 결론을 얻었다.

태양광 시뮬레이터와 PCS를 이용한 배터리 방전시스템 구성 (Battery Discharge System Configuration using Photovoltaic Simulator and PCS)

  • 정다움;박성민;박성미;박성준;문승필
    • 한국산업융합학회 논문집
    • /
    • 제23권3호
    • /
    • pp.491-498
    • /
    • 2020
  • Recently, In the production line of batteries, charge and discharge tests are essential to verify battery characteristics. In this case, the battery charging uses a unidirectional AC/DC converter capable of output voltage and current control, and the discharge uses a resistive load. Since this method consumes energy during discharge, it must be replaced with a bi-directional AC/DC converter system capable of charging and discharging. Although it is difficult to replace the connected inverter part of the bi-directional AC/DC converter system due to the high cost, the spread of the solar-connected inverter rapidly increases as the current solar supply business is activated, and thereby the solar-connected type Inverter prices are plunging. If it can be used as a power converter for battery discharge without program modification of the solar-powered inverter, it will have competition. In this paper, propose a new battery discharge system using a combination of a photovoltaic DC/DC simulator and photovoltaic PCS using a battery to be used as a power converter for battery discharge without program modification of a low-cost photovoltaic inverter. In addition, propose an optimal solar characteristic curve for the stable operation of PCS. The validity of the proposed system was verified using a 500[W] class solar DC/DC simulator and a solar PCS prototype.

RF/DC 방전을 이용한 고 진공용SUS 용기세정에 관한 연구 (A study on the RE/DC discharge cleaning for high vacuum SUS chamber)

  • 김정형;임종연;서인용;정광화
    • 한국진공학회지
    • /
    • 제10권3호
    • /
    • pp.298-302
    • /
    • 2001
  • 초청정을 요구하는 진공용기의 내벽세정을 위한 RF 및 DC 방전세정장치를 제작하여 여러 가지 방전조건에 따라 세정효과를 조사하였다. Baking없이 방전세정만을 수행하였을 때는 baking만 진행했을 때와 비슷한 세정효과를 나타내었으며 세정후의 탈기체율은 반으로 줄어들었다. Baking과 방전세정을 동시에 진행하면 세정효과가 매우 증대되어 세정후의 탈기체율이 1/20으로 감소하였다. Baking과 방전세정을 동시에 수행 시 여러 방전조건에 따른 세정효과를 조사하였는데 이온이 진공용기 내벽에 부딪히며 세정을 할 때 이온에너지와 이온밀도가 중요한 역할을 하는 것으로 보였다. 진공용기를 세정함에 있어 RF방전세정이 DC 방전세정보다 효과적이라는 결과를 얻었다.

  • PDF

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

AC와 DC 코로나 처리에 따른 폴리에스테르 직물의 접착성질 비교 (The Comparison of Adhesion Properties on Polyester Fabric by AC and DC Corona Treatment)

  • 이재호
    • 접착 및 계면
    • /
    • 제17권3호
    • /
    • pp.104-109
    • /
    • 2016
  • AC 코로나와 DC 코로나 처리 효과들을 비교하기 위해 선행연구의 DC 코로나 처리 조건들과 같이 폴리에스테르 직물들을 전류세기 5, 10, 15 A로, 공급속도 5, 10, 15 m/min로 AC 코로나 처리하였다. 이들의 표면변화를 주사전자현미경(SEM)과 X-ray 광전자분석기(XPS)로 확인하였고, 또한 물리적 성질의 변화를 건조 시와 습윤 시의 접착강도를 통하여 측정하였다. 대기압에서 AC 코로나 방전처리에 의해 폴리에스테르 직물의 표면변화는 DC 코로나 방전과 유사한 경향을 보였다. 일반적으로 AC, DC 코로나 처리 양쪽에서 건조 시의 접착강도는 전류세기와 공급속도가 증가할수록 증가하였으나, 습윤 시의 접착강도는 전류세기가 증가할수록 공급속도가 감소할수록 증가하였다. 전류가 20 A일 때 DC 코로나 방전에서는 탄화가 발생하였으나 AC 코로나에서는 탄화가 발생하지 않았다.

DC μ-Grid 기반 배터리 충/방전 시스템의 에너지 효율에 관한 연구 (A Study on Energy Efficiency of Battery Charge/Discharge System based on DC μ-Grid)

  • 여성대;김종운;이경량;한철규;류태형;김경화;김성권
    • 한국전자통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.1337-1344
    • /
    • 2015
  • Li-ion 배터리를 생산하는데 있어서 충/방전을 통한 formation 과정이 필요하다. 이 과정에서 방전기의 부하 저항을 통해 방전하게 되는데 이때 에너지 손실이 발생한다. 따라서 본 논문에서는 DC ${\mu}-Grid$ 기반의 충/방전 시스템에서 배터리를 효율적으로 운영하는 방안에 대해 연구하였다. 컴퓨터 시뮬레이션 결과, DC ${\mu}-Grid$ 기반의 충/방전 시스템에서 충전 배터리 set 3개 기준 대비 방전 배터리 set의 수가 133%를 초과하게 되면 망 전압이 안정화되는 과정에서 발생하는 전압 fluctuation 폭을 초과하기 때문에 시스템에 치명적인 손상을 야기한다. 따라서 충전 배터리 set 3개 기준 대비 방전 배터리 set의 수를 133%까지 운영할 수 있으며 획기적인 에너지 절감 효과를 확인할 수 있었다.