• Title/Summary/Keyword: D8/17

Search Result 2,469, Processing Time 0.033 seconds

Directivity Gain Improvement Method for UWB Coplanar Patch Antenna (UWB 평면 패치안테나의 지향성이득의 향상 방법)

  • Joo, Chang-Bok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.6
    • /
    • pp.63-70
    • /
    • 2012
  • This paper discussed on the directive gain improvement method of the U-type ultra wide-band(UWB) planar patch antenna model with CPW feeding. For directive gain improvement, the U-type printed patch antenna model with CPW feeding is reconstructed as a microstrip structure by adding a reflection plane with aperture slot. The reflection coefficient of the reconstructed antenna is less than -6.5 dB(VSWR < 3.3) to the characteristic impedance of $50.08{\Omega}$ and showed the directive radiation patterns with the directive gain of 7.5 dBi ~ 10.1 dBi, the front-back ratio of 17.8 dB ~ 28.7 dB and the range of -3dB radiation angle over ${\pm}30^{\circ}$ to the main beam direction of ${\theta}=0^{\circ}$.

Ultra-Wideband Band Pass Filter with Controllable Dual Notched Bands Using the CRLH Stubs (CRLH-Stub를 이용한 이중대역 저지 초광대역 대역통과 여파기)

  • Jung, Seung-Back;Yang, Seung-In
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.65-70
    • /
    • 2012
  • In this paper, a compact UWB (Ultra Wideband) BPF(Band-Pass Filter) with dual notched bands is proposed using a hybrid Composited Right-Left Handed (CRLH) and Defected Ground Structure (DGS). To avoid the interferences such as Wireless LAN (Center frequency: 2.4GHz and 5.8GHz), the CRLH is employed to obtain the dual notched bands and the DGS is used to obtain the wide stop-band above the pass-band. The fabricated filter has good performance and has more than 30dB rejection at the center frequency of 2.4 GHz and 5.8GHz. The dual notched bands are easily movable by changing the CRLH parameter. Also the insertion loss is less than 0.4dB in the lower pass-band and 0.7dB in the upper pass-band, and it has small group delay variation less than 0.6ns. The size of the fabricated filter is very compact (17mm*17mm).

Clinical Analysis of 102 Cases of Open Heart Surgery (개심수술 102례 의 임상적 고찰)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.235-240
    • /
    • 1981
  • A total of 102 patients who had an Open Heart Surgery from April 1976 to July 1981 were reviewed. 55 paeitnts were congenital heart disease and 47 patients were acquired heart disease. Among SS patients of congenital heart disease, 18 T 0 F, 18 V S D, 8 A S D, and each one case of l\ulcorner 0 R V, Truncus arteriosus, Ebstein anomaly, Single ventricle, P D A, P 5, A S D + P 5, E C D, V 5 D + P D A, A - P window, D C R V were noted respectively. In 47 patients of acquired heart disease and one Ebstein patient, 46 prosthetic values were implanted: 17 had M V R, 4 had A V R, 2 had M V R + A V R, and 4 had M V R + T V R and one T V R. The operative mortality was 8.S% in acquired heart disease and 17% in congenital heart disease. The follow up period was between 6 months and 6 years. There were 3 cases of late mortality in acquired heart disease and one case in congenital heart disease.

  • PDF

Design of Ku-Band Phase Locked Harmonic Oscillator (Ku-Band용 위상 고정 고조파 발진기 설계)

  • Lee Kun-Joon;Kim Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.49-55
    • /
    • 2005
  • In this paper, the phase locked harmonic oscillator(PLHO) using the analog PLL(Phase Locked Loop) is designed and implemented for a wireless LAN system. The harmonic oscillator is consisted of a ring resonator, a varactor diode and a PLL circuit. Because the fundamental fiequency of 8.5 GHz is used as the feedback signal for the PLL and the 2nd harmonic of 17.0 GHz is used as the output, a analog frequency divider for the phase comparison in the PLL system can be omitted. For the simple PLL circuit, the SPD(Sampling Phase Detector) as a phase comparator is used. The output power of the phase locked harmonic oscillator is 2.23 dBm at 17 GHz. The fundamental and 3rd harmonic suppressions are -31.5 dBc and -29.0 dBc, respectively. The measured phase noise characteristics are -87.6 dBc/Hz and -95.4 dBc/Hz at the of offset frequency of 1 kHz and 10 kHz from the carrier, respectively.

Design and Fabrication of the Frequency Multiplier for S-band Transponder (S-대역 트랜스폰더용 주파수 체배기 설계 및 제작)

  • Kim, Byung-Soo;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.4
    • /
    • pp.348-355
    • /
    • 2006
  • In this paper, frequency multipliers used S-band transponder of the KOMPSAT 3 are designed and fabricated. In the transponder, 108 times multiplier which generate 1st LO signal(2008.8MHz) is comprised of the X9 frequency multiplier, 1st X2 multiplier, 2nd X2 multiplier and the last stage of the X3 frequency multiplier. As results, output power of 8.17 dBm at 2008.8MHz, the harmonic suppression of -56.67dBc, the bandwidth of 14MHz were measured.

  • PDF

Influence of Pre-operative Fasting Time on Blood Glucose in Older Patients (수술 전 금식이 노인환자의 혈당에 미치는 영향)

  • Hong, Mi-Suk;Yoon, Hae-Sang
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • Purpose: This study was performed to identify changes in blood glucose at preoperative fasting time in surgical patients over 60 yr. Methods: Data collection was performed from July, 2008 through July, 2009. Participants consisted of 80 nondiabetic surgical patients. Blood glucose was checked from 3 to 5 times. The 5 times were 2-hr fasting on the pre-operative day (T1, n=80), 8 hr (T2, n=80), 10 hr (T3, n=17), 12 hr (T4, n=34) and 14 hr fasting on the day of the operation (T5, n=29). Results: Of the patients, 27.5% had a blood glucose level of less than 79 mg/dL at T2; 17.6% at T3; 32.4% at T4; and 17.2% at T5. Mean blood glucose levels were 93.8 mg/dL at T1; 88.4 mg/dL at T2; 91.7 mg/dL at T3; 87.4 mg/dL at T4: and 94.1 mg/dL at T5. Blood glucose was the lowest at T2 (p<.001). Conclusion: As 17.6-32.4% of the patients showed the blood glucose level of less than 79 mg/dL at 8-14 hr pre-operative fasting, the authors recommend that surgical patients p>60 yr-of-age be observed for hypoglycemia during pre-operative fasting of more than 10 hr and that surgical patients >60 yr-of-age with risks for hypoglycemia be scheduled for operation within 10 hr preoperative fasting.

Noise-Induced Hearing Disturbance of Textile Weavers by Individual Pure Tone Threshold Determination Test in Taegu City (대구시내(大邱市內) 일부(一部) 방직공장(紡織工場)의 기직공(機織工)에 대(對)한 개별청력검사(個別聽力檢査) 보고(報告))

  • Park, Hong-Chin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.1
    • /
    • pp.177-183
    • /
    • 1974
  • It is generally recognized that the environmental noise of the various working places thought to be the cause of hearing disturbance. This survey was carried out to evaluate the prevalence of noise-induced occupational bearing loss among the weavers of 39 textile industries in Taegu, Korea. For this survey, 432 male workers and 2,023 female workers were examined their hearing acuity by Individual pure tone threshold determination test(air conduction), from November, 1972, to January, 1973. Main findings were as follows : 1. The mean of noise intensity of the 54 weaving rooms was, in over all, $95.6{\pm}4.2dB\;(A),\;95.9{\pm}4.0dB\;(B)\;and\;96.2{\pm}3.9dB\;(C)$. 2. The mean hearing threshold levels by service years in the 4,000 Hz were intensively increased from 1st to 3rd year and slightly decreased. than that of 3rd year, from after 3rd to 5th year, after 5th year that increased slightly. 3. The mean hearing threshold levels by frequencies were highest in the 4,000 Hz(male: $25.0{\pm}11.3dB$, female: $22.0{\pm}10.2dB$) and followed by 6,000, 8,000 and 3,000 Hz. 4. The mean hearing threshold level of the 6,000 Hz (male: 17.0 dB. female: 17.9dB) was higher than that of 4,000Hz (male: 16.4 dB, female: 17.1dB) in tile 1st service year. 5. The mean hearing loss of examinees was $16.2{\pm}8.0dB$ in male and $15.4{\pm}7.8dB$ in female.

  • PDF

Design of LNA Using EM simulator (EM 시뮬레이터를 이용한 LNA 설계)

  • Choi, Moon-Ho;Kim, Yeong-Seuk;Jung, Sung-Il;Lee, Han-Yeong;Jang, Seuk-Hwan;Lee, Jong-Arc
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.873-876
    • /
    • 2005
  • A low noise amplifier(LNA) using electro-magnetic field simulator is designed in standard 0.25um CMOS process. Integrated spiral inductor is simulated using EM field solver. Then LNA is simulated with active device, capacitor and simulated inductor by EM field solver. A S11 and S21 of -15.45dB and 17.8dB at 2.3GHz as simulation results was achieved. A Noise Figure is 2.92dB. And Measurements show a S11 and S21 of -12.4dB and 17.8dB at 2.3GHz. A Noise Figure of 3.3dB was achieved.

  • PDF

A study on Noise Generation and Awareness of the Fire Alarm Sound in the Factory (공장소음으로 인한 화재 경보음 인지 영향정도에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.97-103
    • /
    • 2015
  • The people who are in the noise factory are difficult to hear and recognize about fire and to evacuate quickly when a fire occurs. This study was conducted to analyze workplace's background noise of 31 factories in Incheon and to know the workplace noise level comparing to fire alarm sound level. The measured average noise level was 96.8dB(A). Noise level of measured result was exceeded as 6.8dB(A) comparing to NFSC (National Fire Safety Code) noise level of 90dB. NFPA suggests that when background noise exceeds 85dB or more than that, other methods should be considered to know alarm sound. Also fire alarm sound should exceed more than 15dB(A) comparing to background noise level. Therefore it was concluded that the design of the fire alarm systems should not be applied to the workplace without considering background noise and it needs to be improved with regulations and the systems.