• 제목/요약/키워드: D8/17

검색결과 2,467건 처리시간 0.032초

A Fully Integrated Dual-Band WLP CMOS Power Amplifier for 802.11n WLAN Applications

  • Baek, Seungjun;Ahn, Hyunjin;Ryu, Hyunsik;Nam, Ilku;An, Deokgi;Choi, Doo-Hyouk;Byun, Mun-Sub;Jeong, Minsu;Kim, Bo-Eun;Lee, Ockgoo
    • Journal of electromagnetic engineering and science
    • /
    • 제17권1호
    • /
    • pp.20-28
    • /
    • 2017
  • A fully integrated dual-band CMOS power amplifier (PA) is developed for 802.11n WLAN applications using wafer-level package (WLP) technology. This paper presents a detailed design for the optimal impedance of dual-band PA (2 GHz/5 GHz PA) output transformers with low loss, which is provided by using 2:2 and 2:1 output transformers for the 2 GHz PA and the 5 GHz PA, respectively. In addition, several design issues in the dual-band PA design using WLP technology are addressed, and a design method is proposed. All considerations for the design of dual-band WLP PA are fully reflected in the design procedure. The 2 GHz WLP CMOS PA produces a saturated power of 26.3 dBm with a peak power-added efficiency (PAE) of 32.9%. The 5 GHz WLP CMOS PA produces a saturated power of 24.7 dBm with a PAE of 22.2%. The PA is tested using an 802.11n signal, which satisfies the stringent error vector magnitude (EVM) and mask requirements. It achieved an EVM of -28 dB at an output power of 19.5 dBm with a PAE of 13.1% at 2.45 GHz and an EVM of -28 dB at an output power of 18.1 dBm with a PAE of 8.9% at 5.8 GHz.

자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향 (Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode)

  • 정운찬;주영철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Caffeine, 철분 및 vitamin E 혼합투여시 rat의 혈액과 간조직내에서 혈액화학성분과 지질 및 단백질 구성성분의 변화 (Changes of the blood chemistry, lipid and protein components in blood and liver tissue of the rat after oral combined administration of caffeine, iron and vitamin E)

  • 도재철;허린수
    • 대한수의학회지
    • /
    • 제36권3호
    • /
    • pp.577-598
    • /
    • 1996
  • This study was conducted to identify the effects of caffeine or combinations of caffeine and iron or vitamin E on the lipid and protein components or blood chemistry levels of the serum as well as the total homogenate, mitochondrial and microsomal fraction of the rat(Sprague-Dawley, female) liver. Chronic test were conducted to determine those effects. The chronic test was conducted by dividing rats into 5 groups according to the type of drugs and dosages administrated as follows; the control(group A), and group B was given 25mg/kg caffeine orally once daily for 30 days, group C was given 50mg/kg caffeine orally once daily for 30 days, group D was given 25mg/kg caffeine and orally ferric chloride once daily for 30 days and group E was given 25mg/kg caffeine and 25mg/kg vitamin E once daily for 30 days. The concentrations of glucose, urea nitrogen, uric acid, creatinine, total protein, albumin, A/G ratio, triglyceride, total cholesterol, HDL-cholesterol, free fatty acid, phospholipid as well as the activities of alanine aminotransferase(ALT), aspartate aminotransferase(AST) and alkaline phosphatase(ALP) were measured in the serum of each experimental groups. The concentrations of the carbonyl group and malondiaidehyde(MDA) and the patterns of the SDS-PAGE(Sodium Dodecyl Sulfate - Polyacrylamide Gel Electrophoresis) and fatty acid compositions in free fatty acids and phospholipids were analyzed to determine the oxidative damages and metabolic changes on the lipid and protein components in the serum, and total homogenate, mitochondrial and microsomal fractions of the rat liver. The results obtained from this study were summarized as follows; 1. Body weights of groups B, C, D and E were significantly decreased(p < 0.01) in comparison with that of the control in the chronic test. 2. The concentrations of serum glucose in groups B(124.5mg/dl), C(130.1mg/dl), D(122.1mg/dl), E(119.3mg/dl) were significantly higher(p < 0.01) in comparison to that of the control(101.5mg/dl). But, there were no significant differences in the concentrations of urea nitrogen, uric acid, creatinine, total protein, albumin and A/G ratio in comparison to that of the control. 3. The concentrations of total cholesterol and HDL-cholesterol in serum of groups B(69.6, 53.4mg/dl), C(73.0, 56.3mg/dl), D(68.9, 51.1mg/dl) and E(68.2, 51.3mg/dl) were significantly higher(p < 0.01) in comparison to that of the control(52.6, 38.8mg/dl). On the other hand, the concentrations of triglyceride in serum of groups B(45.0mg/dl), C(40.4mg/dl), D(33.8mg/dl) and E(47.2mg/dl) were significantly lower(p < 0.01) in comparison to that of the control(66.2mg/dl). There were no significant differences in the activities of ALT, AST and ALP in comparison to that of the control. 4. The concentrations of free fatty acid and phospholipid in serum of groups B(45.7, 154.4mg/dl), C(50.0, 167.2mg/dl), D(52.5, 148.4mg/dl) and E(41.1, 159.2mg/dl) were higher(p < 0.01) in comparison to that of the control(35.2, 125.3mg/dl). And the concentrations of the carbonyl group and malondialdehyde in serum of group D(1.82, 0.52nM/mg protein) were significantly higher(p < 0.01) in comparison to the control(1.53nM/mg protein). 5. The concentrations of carbonyl group in total homogenate, mitochondrial and microsomal fraction of group D(1.45, 0.94, 1.67nM/mg protein) were significantly higher (p < 0.01) in comparison to the control(1.16, 0.66, 1.27nM/mg protein). And the concentrations of malondialdehyde in the total homogenate, mitochondrial and microsomal fraction of group D(6.70, 6.10, 1.36nM/mg protein) were significantly higher(p < 0.01) in comparison to the control(5.17, 3.64, 0.68nM/mg protein). 6. As the analytical results of the fatty acid compositions of free fatty acid in serum, the proportions of stearic acid and arachidonic acid of groups B(16.52, 12.62%), C(17.52, 15.18%), D(19.73, 13.47%) and E(17.62, 13.28%) were significantly higher(p < 0.01) in comparison to the control(14.75, 7.88%), but the proportions of oleic acid and linoleic acid of groups B(12.97, 32.59%), C(10.88, 31.23%), D(12.37, 30.66%) and E(11.95, 32.41%) were significantly lower(p < 0.01) in comparison to the control(16.44, 35.12%). Otherwise, as the results of the fatty acid compositions of phospholipid in serum, the proportions of stearic acid and arachidonic acid of groups B(39.37, 16.39%), C(40.63, 17.83%), D(42.73, 15.39%) and E(39.16, 15.70%) were significantly higher(p < 0.01) in comparison to the control(37.74, 14.24%), but the proportions of oleic acid and linoleic acid of groups B(4.03, 14.38%), C(3.54, 12.38%), D(4.52, 11.68%) and E(4.29, 13.64%) were significantly lower(p < 0.01) in comparison to the control(5.53, 16.14%). 7. As the analytical results of the fatty acid compositions of free fatty acid in total homogenate, mitochondrial and microsomal fraction of liver, the proportions of oleic acid of groups B(7.8**, 8.73**, 6.88%) and C(6.89**, 7.75**, 6.58%) were lower(**:p < 0.01) in comparison to the control(8.67, 10.08, 7.81%), but the proportions of arachidonic acid of group C(22.62, 19.79, 23.71%) were significantly higher(p < 0.01) in comparison to the control(20.93, 18.47, 22.24%). And the proportions of palmitic acid of group D(25.95**, 26.16, 26.34**%) were significantly higher(**:p < 0.01) in comparison to the control(24.43, 25.42, 23.34%). In addition, the proportions of linoleic acid of group D(23.43, 25.02, 23.95%) were also significantly higher(p < 0.01) in comparison to the control(22.17, 23.75, 21.26%). The proportions of stearic acid of group D(19.87, 19.76**%) in mitochondrial and microsomal fraction were lower(**:p < 0.01) in comparison to the control(21.01, 24.18%), and the proportions of stearic acid of group E(16.71*, 19.65**%) in mitochondrial and microsomal fraction were significantly lower(**:p < 0.01, *:p < 0.05) in comparison to the control(21.01, 24.18%), and the proportions of linoleic acid of group E(25.04, 29.20, 26.48%) in total homogenate, mitochondria and microsome were significantly higher(p < 0.01) in comparison to the control(22.17, 23.75, 21.26%). 8. As the results of the fatty acid compositions of phospholipid in total homogenate, mitochondrial and microsomal fraction of liver, the proportions of palmitic acid of group D(17.58**, 18.78*, 18.23%**) were significantly higher(**:p < 0.01, *:p < 0.05) in comparison to the control(16.28, 17.22, 16.38%), and the proportions of stearic acid of group D(36.41, 37.23, 39.53%) were also significantly higher(p < 0.01) in comparison to the control(34.18, 34.16, 36.04%). But the proportions of oleic acid(3.41*, 3.11**, 3.12**%) and linoleic acid (18.03**, 15.79**, 14.74**%) of group D were significantly lower(**:p < 0.01, *:p < 0.05) in comparison to the control(oleic : 3.63, 3.72, 3.79%, linoleic : 20.03, 18.71, 18.48%). 9. In order to determine the oxidative damages to the protein in serum, mitochondrial and microsomal fraction of the rat liver, the patterns of the SDS-PAGE were identified, but the results of SDS-PAGE were not significantly different between the control and experimental groups.

  • PDF

영역분할법을 이용한 2차원 유한차분 시간영역법 해석 (2D Finite Difference Time Domain Method Using the Domain Decomposition Method)

  • 홍익표
    • 한국정보통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.1049-1054
    • /
    • 2013
  • 본 논문에서는 영역분할법을 이용한 2차원 유한차분시간영역법을 제안하였다. 영역분할법은 전체 해석구조를 분할하여 해석하는 수치해석방법으로 본 논문에서는 영역분할법 중 Schur complement 방법을 적용한 유한차분 시간영역법을 구현하고 시뮬레이션 모델로 2차원 해석구조를 설정하고 사각형의 도체에 입사하는 전자파의 산란특성을 해석하였다. 2차원 해석구조를 4개의 영역과 8개의 영역으로 각각 나누어 전자파특성을 계산하였고, 제안한 해석방법의 유효함을 입증하기 위해 일반적인 전체영역에 대한 2차원 유한차분 시간영역법의 해석결과와 비교하여 잘 일치하는 것을 확인하였다.

3차원 CAD/CAM을 활용한 액정용 실드 케이스의 스트립 레이아웃 설계에 관한 연구 (Study on The Strip Layout Design of LCD Shield Case Using 3D CAD/CAM)

  • 최계광
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.979-983
    • /
    • 2007
  • 본 논문에서는 액정용 실드 케이스 (Shield Case)의 스트립 레이아웃 도 작성하였다. 프레스 금형에 있어서 스트립 레이아웃 도는 제품 양산을 결정하는 중요 요인이다. 장착되는 다른 부품과의 간섭요인을 용이하게 수정하기 위하여 3D CAD/CAM 시스템을 적용하였다. 블랭크 레이아웃을 최적화하고 광폭배열로 스트립 레이아웃 하여 재료 이용률을 60.17%로 향상시켰다. 또한 얇은 소재두께로 인해 변형 발생이 예상되는 노칭부위에 집중적으로 비딩공정을 추가하여 제품의 평탄도를 요구사항에 맞게 적용하였다. 사용된 3D CAD/CAM 소프트웨어는 Unigraphics NX 3.0이며 12개 공정으로 스트립 레이아웃 도를 작성하였다.

  • PDF

마이크로스트립 콤 어레이 안테나에서 CSRR-메타물질의 영향에 관한 연구 (A Study on the effects of CSRR-metamaterial on Microstrip Comb-line Array Antennas)

  • 기현철
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.187-192
    • /
    • 2017
  • 마이크로스트립 콤 어레이 안테나에 대한 CSRR-메타물질의 영향을 연구하였다. 마이크로스트립 콤 어레이 안테나는 12개의 방사체로 구성되었고 24GHz ISM 대역에서 16.09dBi의 이득과 0.24GHz 대역폭을 갖도록 설계하였다. 설계된 안테나는 안테나 면에 수직한 방사빔과 16.09dBi의 동일편파 이득, -10.86dBi의 교차편파 이득을 갖고 있었다. CSRR-메타물질은 0.24GHz이던 마이크로스트립 콤 어레이 안테나의 임피던스 대역폭을 3.6GHz로 대폭 증가시켰으나 동일편파 이득이 10.8dBi로 되고 교차편파 이득이 14.1dBi로 되어 동일편파와 교차편파가 혼재했으며 안테나 이득을 1.99dB 만큼 저하시켰다. 한편, CSRR 링의 스플릿 방향에 따른 연구에서 링의 스플릿 방향을 위로하거나 아래로 했을 때는 거의 같은 특성을 보였다. 그러나 링의 스플릿 방향을 위와 아래로 교번하여 배치하였을 때는 동일편파 이득이 -1.29dBi로 감소하고 교차편파 이득이 13.9dBi로 증가하여 교차편파가 주가 되는 파로 변환되었다.

지상라이다를 활용한 소나무 산불피해지의 임목 피해특성 분석 (Characteristics Analysis of Burned tree by Terrestrial LiDAR in Forest Fired Area of Pinus densiflora)

  • 강진택;고치웅;임종수;이선정;문가현;이승현
    • 대한원격탐사학회지
    • /
    • 제36권6_1호
    • /
    • pp.1291-1302
    • /
    • 2020
  • 지상라이다의 활용성 검증을 위하여 지상라이다를 이용하여 산불피해지의 임목 피해특성 조사 결과를 전문가에 의해 조사한 결과와 비교하였다. 조사구는 산록에서 산정으로 30 m×50 m(0.15 ha) 규모로 4 plots를 설정하였으며, 조사구내 피해임목의 흉고직경, 수고, 지하고, 지하고, 연소높이 및 수관길이를 조사하였다. 동시에 지상 레이저 스캐너를 이용하여 조사구내 피해임목의 피해특성 정보를 조사하여 전문가 조사결과와 비교분석 하였다. 전문가 조사와 라이다 조사의 비교 결과, 흉고직경은 30.8 cm, 29.7 cm, 수고 15.8 m, 17.5 m, 지하고 8.4 m, 8.4 m, 연소높이 4.0 m, 3.5 m, 수관길이 7.4 cm, 9.1 cm로 나타났다. 두 조사 방법 간에는 수고와 수관길이를 제외한 나머지 조사항목에서는 유의적인 차이를 보이지 않았다. 또한 개체목의 안정성과 고사율에 영향을 미치는 H/D율과 CL/H율, BH/CL율을 분석한 결과, 전문가 조사 51.3%, 47.1%, 53.6%, 라이다 조사 58.8%, 52.0%, 38.7%로 나타났다.

축소모형주택을 이용한 전통창호의 차음성능에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Windows by Using a Scale Model House)

  • 신훈;장길수;송민정
    • 한국주거학회논문집
    • /
    • 제17권5호
    • /
    • pp.47-54
    • /
    • 2006
  • This study aims to evaluate the sound insulation performance of Korean traditional paper(Hanji) windows as a material of environmental friendly building. Six types of traditional windows with 4 types of traditional window positions, were installed in l/2.5 scale model house. And then according to KS F 2235, comparative sound level differences between outdoor and indoor were measured. The main results are as follows; 1) TL(Transmission Loss) of Korean traditional paper windows, which cover one eighth of total balcony window, are ranged from 15 to 19 dB(A) in the living room and from 8 to 11 dB(A) in the balcony space. 2) TL of Korean traditional paper windows, which cover one fourth of total balcony window, are ranged from 10 to 19 dB(A) in the living room and from 8 to 10 dB(A) in the balcony space. 3) TL of Korean traditional windows with one side-one layer paper is ranged from 10 to 21 dB(A) and two side-one layer paper is 15 to 23 dB(A) and two side-two layer paper is 19 to 23 dB(A) respectively.

Evaluation of Health-Related Quality of Life among Patients with Cervical Cancer in Indonesia

  • Endarti, Dwi;Riewpaiboon, Arthorn;Thavorncharoensap, Montarat;Praditsitthikorn, Naiyana;Hutubessy, Raymond;Kristina, Susi Ari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3345-3350
    • /
    • 2015
  • Background: Evaluation of health-related quality of life (HRQOL) in cervical cancer patients is important in order to design the interventions for improving patient outcomes. Reports of HRQOL among cervical cancer patients in Indonesia are limited. Moreover, measurement using EQ-5D-3L is to our best knowledge has hitherto not been performed. This study aimed to examine the HRQOL of cervical cancer patients in Indonesia using EQ-5D-3L. Materials and Methods: A cross-sectional study was conducted by interviewing cervical cancer patients using the EQ-5D-3L questionnaire. Percentages of patients who reported having problems in each dimension of EQ-5D as well as EQ-5D index score (utility) were calculated. Results: Our findings indicated that the most frequent reported problems were pain/discomfort (67.8%) followed by anxiety/depression (57.5%). The mean of EQ-5D VAS was 75.8 (SD=17.0). The mean (SD) utility scores were 0.85 (0.19), 0.76 (0.20), 0.71 (0.21), and 0.77 (0.13) for cervical cancer patients in stage I, II, III, and IV, respectively. Conclusions: Cervical cancer significantly affects patient HRQOL. Efforts should be made to improve the quality of life of cervical cancer patients especially in terms of pain /discomfort and anxiety/depression reduction.

홀수개의 폴딩 블록으로 구현된 1.2V 8-bit 800MSPS CMOS A/D 변환기 (An 1.2V 8-bit 800MSPS CMOS A/D Converter with an Odd Number of Folding Block)

  • 이동헌;문준호;송민규
    • 대한전자공학회논문지SD
    • /
    • 제47권7호
    • /
    • pp.61-69
    • /
    • 2010
  • 본 논문에서는 기존 폴딩 구조의 A/D 변환기(ADC)가 지닌 경계조건 비대칭 오차를 극복하기 위해 홀수개의 폴딩 블록을 사용한 1.2V 8b 800MSPS CMOS ADC를 제안한다. 제안하는 ADC는 저 전력소모를 위해 폴딩 구조에 저항열 인터폴레이션 기법을 적용하고, 높은 folding rate(FR=9)를 극복하기 위해 cascaded 폴딩 구조를 채택하였다. 특히 폴딩 ADC의 주된 문제인 아날로그 신호의 선형성 왜곡과 offset 오차 감소를 위해 홀수개의 폴딩 블록을 사용하는 신호처리 기법을 제안하였다. 또한 스위치를 사용한 ROM 구조의 인코더를 채택하여 $2^n$ 주기를 가지지 않는 디지털 코드를 일반적인 바이너리 코드로 출력하였다. 제안하는 ADC는 $0.13{\mu}m$ 1P6M CMOS 공정을 사용하여 설계되었으며, 유효면적은 870um$\times$980um이다. 입력주파수 10MHz, 800MHz의 변환속도에서 150mW의 낮은 전력소모 특성을 보이며 SNDR은 44.84dB (ENOB 7.15bit), SFDR은 52.17dB의 측정결과를 확인하였다.