• Title/Summary/Keyword: D8/17

Search Result 2,467, Processing Time 0.033 seconds

A Fully Integrated Dual-Band WLP CMOS Power Amplifier for 802.11n WLAN Applications

  • Baek, Seungjun;Ahn, Hyunjin;Ryu, Hyunsik;Nam, Ilku;An, Deokgi;Choi, Doo-Hyouk;Byun, Mun-Sub;Jeong, Minsu;Kim, Bo-Eun;Lee, Ockgoo
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.1
    • /
    • pp.20-28
    • /
    • 2017
  • A fully integrated dual-band CMOS power amplifier (PA) is developed for 802.11n WLAN applications using wafer-level package (WLP) technology. This paper presents a detailed design for the optimal impedance of dual-band PA (2 GHz/5 GHz PA) output transformers with low loss, which is provided by using 2:2 and 2:1 output transformers for the 2 GHz PA and the 5 GHz PA, respectively. In addition, several design issues in the dual-band PA design using WLP technology are addressed, and a design method is proposed. All considerations for the design of dual-band WLP PA are fully reflected in the design procedure. The 2 GHz WLP CMOS PA produces a saturated power of 26.3 dBm with a peak power-added efficiency (PAE) of 32.9%. The 5 GHz WLP CMOS PA produces a saturated power of 24.7 dBm with a PAE of 22.2%. The PA is tested using an 802.11n signal, which satisfies the stringent error vector magnitude (EVM) and mask requirements. It achieved an EVM of -28 dB at an output power of 19.5 dBm with a PAE of 13.1% at 2.45 GHz and an EVM of -28 dB at an output power of 18.1 dBm with a PAE of 8.9% at 5.8 GHz.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

Changes of the blood chemistry, lipid and protein components in blood and liver tissue of the rat after oral combined administration of caffeine, iron and vitamin E (Caffeine, 철분 및 vitamin E 혼합투여시 rat의 혈액과 간조직내에서 혈액화학성분과 지질 및 단백질 구성성분의 변화)

  • Do, Jae-cheul;Huh, Rhin-sou
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.577-598
    • /
    • 1996
  • This study was conducted to identify the effects of caffeine or combinations of caffeine and iron or vitamin E on the lipid and protein components or blood chemistry levels of the serum as well as the total homogenate, mitochondrial and microsomal fraction of the rat(Sprague-Dawley, female) liver. Chronic test were conducted to determine those effects. The chronic test was conducted by dividing rats into 5 groups according to the type of drugs and dosages administrated as follows; the control(group A), and group B was given 25mg/kg caffeine orally once daily for 30 days, group C was given 50mg/kg caffeine orally once daily for 30 days, group D was given 25mg/kg caffeine and orally ferric chloride once daily for 30 days and group E was given 25mg/kg caffeine and 25mg/kg vitamin E once daily for 30 days. The concentrations of glucose, urea nitrogen, uric acid, creatinine, total protein, albumin, A/G ratio, triglyceride, total cholesterol, HDL-cholesterol, free fatty acid, phospholipid as well as the activities of alanine aminotransferase(ALT), aspartate aminotransferase(AST) and alkaline phosphatase(ALP) were measured in the serum of each experimental groups. The concentrations of the carbonyl group and malondiaidehyde(MDA) and the patterns of the SDS-PAGE(Sodium Dodecyl Sulfate - Polyacrylamide Gel Electrophoresis) and fatty acid compositions in free fatty acids and phospholipids were analyzed to determine the oxidative damages and metabolic changes on the lipid and protein components in the serum, and total homogenate, mitochondrial and microsomal fractions of the rat liver. The results obtained from this study were summarized as follows; 1. Body weights of groups B, C, D and E were significantly decreased(p < 0.01) in comparison with that of the control in the chronic test. 2. The concentrations of serum glucose in groups B(124.5mg/dl), C(130.1mg/dl), D(122.1mg/dl), E(119.3mg/dl) were significantly higher(p < 0.01) in comparison to that of the control(101.5mg/dl). But, there were no significant differences in the concentrations of urea nitrogen, uric acid, creatinine, total protein, albumin and A/G ratio in comparison to that of the control. 3. The concentrations of total cholesterol and HDL-cholesterol in serum of groups B(69.6, 53.4mg/dl), C(73.0, 56.3mg/dl), D(68.9, 51.1mg/dl) and E(68.2, 51.3mg/dl) were significantly higher(p < 0.01) in comparison to that of the control(52.6, 38.8mg/dl). On the other hand, the concentrations of triglyceride in serum of groups B(45.0mg/dl), C(40.4mg/dl), D(33.8mg/dl) and E(47.2mg/dl) were significantly lower(p < 0.01) in comparison to that of the control(66.2mg/dl). There were no significant differences in the activities of ALT, AST and ALP in comparison to that of the control. 4. The concentrations of free fatty acid and phospholipid in serum of groups B(45.7, 154.4mg/dl), C(50.0, 167.2mg/dl), D(52.5, 148.4mg/dl) and E(41.1, 159.2mg/dl) were higher(p < 0.01) in comparison to that of the control(35.2, 125.3mg/dl). And the concentrations of the carbonyl group and malondialdehyde in serum of group D(1.82, 0.52nM/mg protein) were significantly higher(p < 0.01) in comparison to the control(1.53nM/mg protein). 5. The concentrations of carbonyl group in total homogenate, mitochondrial and microsomal fraction of group D(1.45, 0.94, 1.67nM/mg protein) were significantly higher (p < 0.01) in comparison to the control(1.16, 0.66, 1.27nM/mg protein). And the concentrations of malondialdehyde in the total homogenate, mitochondrial and microsomal fraction of group D(6.70, 6.10, 1.36nM/mg protein) were significantly higher(p < 0.01) in comparison to the control(5.17, 3.64, 0.68nM/mg protein). 6. As the analytical results of the fatty acid compositions of free fatty acid in serum, the proportions of stearic acid and arachidonic acid of groups B(16.52, 12.62%), C(17.52, 15.18%), D(19.73, 13.47%) and E(17.62, 13.28%) were significantly higher(p < 0.01) in comparison to the control(14.75, 7.88%), but the proportions of oleic acid and linoleic acid of groups B(12.97, 32.59%), C(10.88, 31.23%), D(12.37, 30.66%) and E(11.95, 32.41%) were significantly lower(p < 0.01) in comparison to the control(16.44, 35.12%). Otherwise, as the results of the fatty acid compositions of phospholipid in serum, the proportions of stearic acid and arachidonic acid of groups B(39.37, 16.39%), C(40.63, 17.83%), D(42.73, 15.39%) and E(39.16, 15.70%) were significantly higher(p < 0.01) in comparison to the control(37.74, 14.24%), but the proportions of oleic acid and linoleic acid of groups B(4.03, 14.38%), C(3.54, 12.38%), D(4.52, 11.68%) and E(4.29, 13.64%) were significantly lower(p < 0.01) in comparison to the control(5.53, 16.14%). 7. As the analytical results of the fatty acid compositions of free fatty acid in total homogenate, mitochondrial and microsomal fraction of liver, the proportions of oleic acid of groups B(7.8**, 8.73**, 6.88%) and C(6.89**, 7.75**, 6.58%) were lower(**:p < 0.01) in comparison to the control(8.67, 10.08, 7.81%), but the proportions of arachidonic acid of group C(22.62, 19.79, 23.71%) were significantly higher(p < 0.01) in comparison to the control(20.93, 18.47, 22.24%). And the proportions of palmitic acid of group D(25.95**, 26.16, 26.34**%) were significantly higher(**:p < 0.01) in comparison to the control(24.43, 25.42, 23.34%). In addition, the proportions of linoleic acid of group D(23.43, 25.02, 23.95%) were also significantly higher(p < 0.01) in comparison to the control(22.17, 23.75, 21.26%). The proportions of stearic acid of group D(19.87, 19.76**%) in mitochondrial and microsomal fraction were lower(**:p < 0.01) in comparison to the control(21.01, 24.18%), and the proportions of stearic acid of group E(16.71*, 19.65**%) in mitochondrial and microsomal fraction were significantly lower(**:p < 0.01, *:p < 0.05) in comparison to the control(21.01, 24.18%), and the proportions of linoleic acid of group E(25.04, 29.20, 26.48%) in total homogenate, mitochondria and microsome were significantly higher(p < 0.01) in comparison to the control(22.17, 23.75, 21.26%). 8. As the results of the fatty acid compositions of phospholipid in total homogenate, mitochondrial and microsomal fraction of liver, the proportions of palmitic acid of group D(17.58**, 18.78*, 18.23%**) were significantly higher(**:p < 0.01, *:p < 0.05) in comparison to the control(16.28, 17.22, 16.38%), and the proportions of stearic acid of group D(36.41, 37.23, 39.53%) were also significantly higher(p < 0.01) in comparison to the control(34.18, 34.16, 36.04%). But the proportions of oleic acid(3.41*, 3.11**, 3.12**%) and linoleic acid (18.03**, 15.79**, 14.74**%) of group D were significantly lower(**:p < 0.01, *:p < 0.05) in comparison to the control(oleic : 3.63, 3.72, 3.79%, linoleic : 20.03, 18.71, 18.48%). 9. In order to determine the oxidative damages to the protein in serum, mitochondrial and microsomal fraction of the rat liver, the patterns of the SDS-PAGE were identified, but the results of SDS-PAGE were not significantly different between the control and experimental groups.

  • PDF

2D Finite Difference Time Domain Method Using the Domain Decomposition Method (영역분할법을 이용한 2차원 유한차분 시간영역법 해석)

  • Hong, Ic-Pyo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1049-1054
    • /
    • 2013
  • In this paper, two-dimensional(2-D) Finite Difference Time Domain(FDTD) method using the domain decomposition method is proposed. We calculated the electromagnetic scattering field of a two dimensional rectangular Perfect Electric Conductor(PEC) structure using the 2-D FDTD method with Schur complement method as a domain decomposition method. Four domain decomposition and eight domain decomposition are applied for the analysis of the proposed structure. To validate the simulation results, the general 2-D FDTD algorithm for the total domain are applied to the same structure and the results show good agreement with the 2-D FDTD using the domain decomposition method.

Study on The Strip Layout Design of LCD Shield Case Using 3D CAD/CAM (3차원 CAD/CAM을 활용한 액정용 실드 케이스의 스트립 레이아웃 설계에 관한 연구)

  • Choi, Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.979-983
    • /
    • 2007
  • In this thesis, a strip layout drawing of LCD S/C (shield case) was prepared. In the press die, strip layout drawing is a major factor that decides the mass production of a product. The 3D CAD/CAM system was applied for the easy correction of the interference factor with other parts to be mounted. The material use ratio was enhanced to 60.17% by optimizing the blank layout and strip layout in double width array. Furthermore, the flatness of the product was made to fit the requirements by adding the bidding process intensively on the notching part where the occurrence of the change in shape is expected owing to the thin material. For the 3D CAD/CAM software, Unigraphics NX3.0 was used. The strip layout drawing was prepared in 12 processes.

  • PDF

A Study on the effects of CSRR-metamaterial on Microstrip Comb-line Array Antennas (마이크로스트립 콤 어레이 안테나에서 CSRR-메타물질의 영향에 관한 연구)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.187-192
    • /
    • 2017
  • We investigated the effects of the CSRR-metamaterial on microstrip comb-line array antennas. Microstrip comb-line array antennas was designed with 12 radiators, gain of 16.09dBi and bandwidth of 0.24GHz in the 24GHz ISM band. The designed antenna had radiation beam perpendicular to the antenna plane, co-polarization gain of 16.09dBi and cross-polarization gain of -10.86dBi. the CSRR-metamaterial increased largely the impedance bandwidth of the antenna from 0.24GHz to 3.6GHz. however as co-polarization gain became 10.08dBi and cross-polarization gain became 14.1dBi, co-polarization was mixed with cross-polarization. And the antenna gain lowered by 1.99dB. On the investigation of the dependence on the split-direction of the CSRR rings, it showed nearly the same characteristics for up-splitted ring used case and down-splitted ring used case. However in the case of arranging up-splitted ring and down-splitted ring in alternation, co-polarization gain decreased to -1.29dBi and cross-polarization gain increased to 13.9dBi, which meant the wave was transited to cross-polarization majority wave.

Characteristics Analysis of Burned tree by Terrestrial LiDAR in Forest Fired Area of Pinus densiflora (지상라이다를 활용한 소나무 산불피해지의 임목 피해특성 분석)

  • Kang, Jin-Taek;Ko, Chi-Ung;Yim, Jong-Su;Lee, Sun-Jeoung;Moon, Ga-Hyun;Lee, Seung-Hyun
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_1
    • /
    • pp.1291-1302
    • /
    • 2020
  • To verify the field-effectiveness of Terrestrial Laser Scanner (TLS), a terrestrial LiDAR was deployed to examine the damage properties of woods in forest fire area, then the data was compared with the results surveyed by a forestry expert. Four sample plots (30 m × 50 m, 0.15 ha) were set from the foot to the top of the mountain, and DBH, height, clear length, burned height, and crown length were investigated. Next, TLS collected information on damage characteristics found in the sample plots. This information was then compared with that amassed by the expert. The expert and the TLS survey results showed 30.8 cm and 29.9 cm for DBH, 15.8 m and 17.5 m for tree height, 8.4 m and 8.4 m for clear length, 4.0 m, 3.5 m for burned height, and 7.4 cm and 9.1 cm for crown length. With the exceptions of height and clear length, no notable discrepancy was observed between two methods. H/D ratio, CL/H ratio, and BH/CL ratio, all of which contribute to stability and decay rate of the stand, from the two methods were also compared. The human survey rated each ratio (H/D, CL/H, BH/CL in order) 51.3%, 47.1%, and 53.6%, while the TLS presented the results of 58.8%, 52.0%, and 38.7%.

An Experimental Study on the Sound Insulation Performance of Korean Traditional Windows by Using a Scale Model House (축소모형주택을 이용한 전통창호의 차음성능에 관한 실험적 연구)

  • Shin, Hoon;Jang, Gil-Soo;Song, Min-Jeong
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.47-54
    • /
    • 2006
  • This study aims to evaluate the sound insulation performance of Korean traditional paper(Hanji) windows as a material of environmental friendly building. Six types of traditional windows with 4 types of traditional window positions, were installed in l/2.5 scale model house. And then according to KS F 2235, comparative sound level differences between outdoor and indoor were measured. The main results are as follows; 1) TL(Transmission Loss) of Korean traditional paper windows, which cover one eighth of total balcony window, are ranged from 15 to 19 dB(A) in the living room and from 8 to 11 dB(A) in the balcony space. 2) TL of Korean traditional paper windows, which cover one fourth of total balcony window, are ranged from 10 to 19 dB(A) in the living room and from 8 to 10 dB(A) in the balcony space. 3) TL of Korean traditional windows with one side-one layer paper is ranged from 10 to 21 dB(A) and two side-one layer paper is 15 to 23 dB(A) and two side-two layer paper is 19 to 23 dB(A) respectively.

Evaluation of Health-Related Quality of Life among Patients with Cervical Cancer in Indonesia

  • Endarti, Dwi;Riewpaiboon, Arthorn;Thavorncharoensap, Montarat;Praditsitthikorn, Naiyana;Hutubessy, Raymond;Kristina, Susi Ari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3345-3350
    • /
    • 2015
  • Background: Evaluation of health-related quality of life (HRQOL) in cervical cancer patients is important in order to design the interventions for improving patient outcomes. Reports of HRQOL among cervical cancer patients in Indonesia are limited. Moreover, measurement using EQ-5D-3L is to our best knowledge has hitherto not been performed. This study aimed to examine the HRQOL of cervical cancer patients in Indonesia using EQ-5D-3L. Materials and Methods: A cross-sectional study was conducted by interviewing cervical cancer patients using the EQ-5D-3L questionnaire. Percentages of patients who reported having problems in each dimension of EQ-5D as well as EQ-5D index score (utility) were calculated. Results: Our findings indicated that the most frequent reported problems were pain/discomfort (67.8%) followed by anxiety/depression (57.5%). The mean of EQ-5D VAS was 75.8 (SD=17.0). The mean (SD) utility scores were 0.85 (0.19), 0.76 (0.20), 0.71 (0.21), and 0.77 (0.13) for cervical cancer patients in stage I, II, III, and IV, respectively. Conclusions: Cervical cancer significantly affects patient HRQOL. Efforts should be made to improve the quality of life of cervical cancer patients especially in terms of pain /discomfort and anxiety/depression reduction.

An 1.2V 8-bit 800MSPS CMOS A/D Converter with an Odd Number of Folding Block (홀수개의 폴딩 블록으로 구현된 1.2V 8-bit 800MSPS CMOS A/D 변환기)

  • Lee, Dong-Heon;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.7
    • /
    • pp.61-69
    • /
    • 2010
  • In this paper, an 1.2V 8b 800MSPS A/D Converter(ADC) with an odd number of folding block to overcome the asymmetrical boundary-condition error is described. The architecture of the proposed ADC is based on a cascaded folding architecture using resistive interpolation technique for low power consumption and high input frequency. The ADC employs a novel odd folding block to improve the distortion of signal linearity and to reduce the offset errors. In the digital block, furthermore, we use a ROM encoder to convert a none-$2^n$-period code into the binary code. The chip has been fabricated with an $0.13{\mu}m$ 1P6M CMOS technology. The effective chip area is $870{\mu}m\times980{\mu}m$. SNDR is 44.84dB (ENOB 7.15bit) and SFDR is 52.17dBc, when the input frequency is 10MHz at sampling frequency of 800MHz.