• Title/Summary/Keyword: D/d ratio

Search Result 9,650, Processing Time 0.036 seconds

Comparison on Compressive Strength of Paraffin Waste Form with H/D Ratio and Loading Rate (붕산함유파라핀 고화체의 직경/높이 및 재하속도에 따른 압축강도비교)

  • 곽경길;유영걸
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.124-129
    • /
    • 2003
  • In case that the mixing weight ratio of waste form between boric acid and paraffin was 3.3/l, which had been adopted in the concentrate waste drying system (CWDS) of domestic nuclear power plants. Using several specimens with different diameters and heights, 50/100mm specimens. compressive strength were measured. The experiment result showed that the small diameter specimens of compressive strength are increased more than large diameter specimens. (d=50>75>100mm) The average compressive strength of specimens showed that the range from 22.43 $\kg/textrm{cm}^2$ to 38.57$\kg/textrm{cm}^2$ (NRC standard$\geq$4.1 $\kg/textrm{cm}^2$). NRC standard is recommended that the compressive strength test specimens be right circular cylinders, 2 to 3 inches in diameter, with a height-to-diameter(H/D) ratio of approximately two. and compressive strength were increased more than large loading rate. As test result, this conditions are a good agreement, and estimated.

  • PDF

Study on the Development of Wet Cell Holder for the Measurement of Hydrophilic Contact Lens (친수성 콘택트렌즈 측정용 Wet Cell 홀더 개발에 관한 연구)

  • Song, Kyoung-Sek;Lim, Hyeon-Sun;Joo, Seok-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • Purpose: To develop more accurate wet measuring system combining the wet cell, automatic lensmeter and the related software for hydrophilic contact lenses and to verify the accuracy of those measuring holder system already available in the market. Methods: Refractive power measurement were done in both a conventional method which has been commonly used in optical shops and a new method which is recently developed in korea. Hydrophilic contact lens of korean brand was chosen as a test material and was tested by water content ratio and by spherical refractive power. Results: When spherical power of -3.00 D contact lens is measured in the newly developed wet cell measurement holder with automatic lensmeter, it reads -3.01 D at water content ratio of 38%. -3.00 D at 45% and -2.98 D at 58%. The same experiment with the Poster soft contact lens wet cell measurement holder maintaining other conditions same resulted in -3.60 D at the water content ratio of 38%, -3.06 D at 45% and -2.46 D at 58%. Conclusions: At the higher water content, the refractive power values measured by both of the wet cell measuring holders are shown lower, and additionally, the new method using the wet cell holder and new software program in a automatic lensmeter showed more accurate readings than conventional Poster soft contact lens wet cell measuring system.

Design of a Broadband Quasi-Yagi Antenna with a 2:1 Impedance Bandwidth Ratio (2:1 임피던스 대역폭 비를 가지는 광대역 quasi-Yagi 안테나 설계)

  • Lee, Jong-Ig;Yeo, Jun-Ho;Park, Jin-Taek
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.760-765
    • /
    • 2012
  • In this paper, we studied a design method for a quasi-Yagi antenna (QYA) with broadband characteristics of an impedance bandwidth ratio greater than 2 : 1 and a gain > 4 dBi. The QYA is fed by a microstrip line fabricated on a coplanar strip line and it consists of 3 elements; a planar dipole, a nearby director close to the dipole, and a ground plane reflector. By placing a wide rectangular patch-type director near to the dipole driver, broadband characteristics are achieved. An optimized 3-element QYA for operation over 1.6-3.5 GHz (bandwidth ratio 2.2 : 1) is fabricated on an FR4 substrate with a size of 90 mm by 90 mm and tested experimentally. The results show an impedance bandwidth of 1.56-3.74 GHz (bandwidth ratio 2.4 : 1) for VSWR < 2, a peak gain of 4.2-6.3 dBi, and a front-to-back ratio (FBR) > 13.6 dB within the bandwidth.

Analysis of Foot Shape and Size System of Male High School Students Using 3D Scan Data (3D 스캔 데이터를 활용한 남자 고등학생의 발 형태 및 치수체계 분석)

  • Shin, Yu Jin;Park, Soonjee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.1
    • /
    • pp.53-67
    • /
    • 2020
  • The purpose of this study is to analyze the foot shape and size specification of male high school students. 3D modeling programs such as 'Artec Studio', 'CATIA', and 'Auto CAD' measured the 3D scan data of 361 male high school students provided by KATS. Through principal factor analysis, 10 factors were extracted, including foot length, medial-lateral ratio, and foot length ratio. As the result of the cluster and ANOVA with post-hoc test (Duncan method), the differences among types were clarified. Type 1 (24.7%) represented outward medial-lateral ratio (M-L ratio) with the lowest instep, ankle and little deformed first toe. Type 2 (41.8%) was characterized by the shortest, even M-L ratio, thin ankle and heel, the highest instep and ankle. Type 3 (33.5%) showed the longest, inward M-L ratio, thick ankle and heel, and deformed first toe. As the cross-tabulation of foot length and ball circumference, 17.2 percent was not covered by KS standard; in addition, the foot length was longer than the KS standard. The correlation analysis of key dimensions showed that foot length and ball circumference were highly correlated with other items; therefore, regression equations were derived to estimate other foot measurements using these two items as independent variables.

The Value Relevance of Advertising Activity based on R&D Intensity and Export Ratio (매출액영업이익률, 매출액성장률, 부채비율 및 기업규모를 고려하여 살펴본 광고선전활동이 기업가치에 미치는 영향 : 한국 제조업 기업을 대상으로 한 연구개발집약도 및 수출비중의 조절효과 분석)

  • Kim, Jinsu;Kwon, Gee Jung
    • International Area Studies Review
    • /
    • v.14 no.3
    • /
    • pp.312-338
    • /
    • 2010
  • This paper investigates the value relevance of advertising activity over the period from 2001 to 2009 in the listed Korean stock markets(KOSPI and KOSDAQ). In addition, this paper divide all sample firm into several subsample, based on R&D intensity and export ratio in total sales. The empirical result of this paper shows following two evidence; First, advertising intensity, which proxies for advertising activity, is significantly related to firm value at the 1% level of significance. Second, advertising activity of high R&D intensity and high export ratio sample firms has more significant value relevance than for firms with low R&D intensity and low export ratio. The empirical results suggest that moderation effect of R&D intensity and export ratio are very important factor in determining the value relevance of advertising activity.

Performance Analysis of the Uni-Directional Radiation Equiangular Antenna over EBG Surface (EBG 표면 위의 단일 방향 복사 등각 안테나의 성능 해석)

  • Yoon, Sung Hyun;Kim, Jae Kwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1622-1630
    • /
    • 2015
  • In this study, we used EBG(electromagnetic band gap) reflector to change bi-directional radiation of circular polarization into uni-directional radiation of equiangular spiral antenna. When the height of spiral arm from EBG reflector is 0.07 wavelength of the lowest operating frequency, the axial ratio of the circular polarization was deteriorated. In this paper, we analyzed the magnitude and the time phase difference of $E_{\theta},E_{\phi}$ that generates right hand circle polarization that is co-polarization at +z direction and proposed the improving condition for axial ratio at all related frequency range. As a result, we obtained that the axial ratio was below 3[dB] at range of 3 ~ 10[dB], the gain was improved about 3[dB] with comparison to bi-directional radiation at free space, and $S_{11}$ was below -10[dB] at all related frequency range.

Shear Bond Strength of 3D Printed Concrete Layers According to Water Cement Ratio and Printing Time Gap (물시멘트비와 프린팅 시간간격에 따른 3D 프린팅 콘크리트 레이어의 전단부착강도)

  • Kim, Jin-Ho;Lee, Yoon Jung;Jeong, Hoseong;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.199-208
    • /
    • 2021
  • The extrudability of 3D printed concrete and its member strength can be highly influenced by water cement ratio (W/C) and printing time gap (PTG). In this study, mold cast specimens and 3D printed specimens were fabricated with variables of W/C ratio and PTG, and their shear bond strength and interlayer surface moisture content were measured and analyzed. The test results showed that the shear bond strength is greatly influenced by the amount of interlayer surface moisture. It is thus recommended that proper amount of interlayer surface moisture with respect to PTG needs to be maintained to have a required interlayer shear bond strength. In addition, further research is required to estimate the effect of many environmental factors that can influence the interlayer surface moisture content.

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Autonomic Nervous System response affected by 3D visual fatigue evoked during watching 3D TV (3D TV 시청으로 유발된 시각피로가 자율신경계 기능에 미치는 영향)

  • Park, Sang-In;Whang, Min-Cheol;Kim, Jong-Wha;Mun, Sung-Chul;Ahn, Sang-Min
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.653-662
    • /
    • 2011
  • As technology in 3D industry has rapidly advanced, a lot of studies primarily focusing on visual function and cognition have become vigorous. However, studies on effect of 3D visual fatigue on autonomic nervous system have not less been conducted. Thus, this study was to identify and determine the effect that might have a negative influence on sympathetic nervous system, parasympathetic nervous system, and cardiovascular system. Fifteen undergraduates (female: 9, mean age: $22.53{\pm}2.55$) participated and were sat on a comfortable chair, viewing a 3D content during about 1 hour. Cardiac responses like SDNN(standard deviation of RR intervals), RMS-SD(root mean squared successive difference), and HF/LF ratios extracted from the measured PPG(Photo-PlethysmoGram) before viewing 3D were compared to those after viewing 3D. The results showed that after subjects watched the 3D, responses in sympathetic nervous system and parasympathetic nervous system were activated and deactivated, respectively relative to those before watching the 3D. The results showed that HF/LF ratio, Ln(LF), and Ln(HF) after viewing 3D were significantly reduced relative to those before viewing 3D. No significant effects were observed in SDNN and RMS-SD. Results obtained in this study showed that visual fatigue induced by watching 3D adversely influenced autonomic nervous system, and thereby reduced heart rate variability causing sympathetic nervous acceleration.

  • PDF

A Study on the Acoustic Properties of Acoustic Treansducer with PZT/Metal (PZT/Metal로 구성된 음향변환기의 음향특성에 관한 연구)

  • Kim, Jin-Soo;Kang, Dae-Ha;Kim, So-Jung;Kim, Ho-Gi;Lee, Deok-Chool
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.28-37
    • /
    • 1992
  • In the study, the Acoustic transducer of a thin circular disc-type with PZT/Metal was manufactured. The 'tape casting method' was introduced to prepare the thin disc-type of piezoelectric ceramics. The acoustic characteristics of PZT/Metal acoustic transducer for piezoelectric buzzer and piezoelectric speaker etc. have been studied and analyzed. As a result, the sound pressure level (dB), in the range from -6dB to -14dB, increased with increasing the piezoelectric coeffeicient ($d_{31}$) of ceramics. The optimal conditions of the sound pressure characteristics of acoustic transducer were that the radius ratio(${\eta}$) of ceramics and metal plate is 0.7-0.8 and the thickness ratio(${\beta}$) is 1.0, and the value were -15~-165dB.

  • PDF