• 제목/요약/키워드: Cyclic loading tests

검색결과 528건 처리시간 0.031초

Investigation on the monotonic behavior of the steel rack upright-beam column connection

  • Cao, Yan;Alyousef, Rayed;Jermsittiparsert, Kittisak;Ho, Lanh Si;Alaskar, Abdulaziz;Alabduljabbar, Hisham;Alrshoudi, Fahed;Mohamed, Abdeliazim Mustafa
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.103-115
    • /
    • 2020
  • The cold-formed steel storage racks are extensively employed in various industries applications such as storing products in reliable places and storehouses before distribution to the market. Racking systems lose their stability under lateral loads, such as seismic actions due to the slenderness of elements and low ductility. This justifies a need for more investigation on methods to improve their behavior and increase their capacity to survive medium to severe loads. A standardized connection could be obtained through investigation on the moment resistance, value of original rotational stiffness, ductility, and failure mode of the connection. A total of six monotonic tests were carried out to determine the behavior of the connection of straight 2.0 mm, and 2.6 mm thickness connects to 5 lug end connectors. Then, the obtained results are benched mark as the original data. Furthermore, an extreme learning machine (ELM) technique has been employed to verify and predict both moment and rotation results. Out of 4 connections, increase the ultimate moment resistance of connection by 13% and 18% for 2.0 mm and 2.6 mm upright connection, respectively.

GFS-CFXB 내진보강법을 이용한 지진피해를 받은 R/C 건물의 내진성능 평가 및 내진보강 효과 (Seismic Strengthening and Performance Evaluation of Damaged R/C Buildings Strengthened with Glass Fiber Sheet and Carbon Fiber X-Brace System)

  • 이강석
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.667-674
    • /
    • 2013
  • 기존 강재 브레이싱 내진보강법은 정착부의 안정성 문제와 브레이싱의 국부좌굴이 발생할 문제가 있으며, 이를 방지하기 위한 추가보강으로 인해 불필요한 자중증가 등으로 경제적인 내진보강성능 확보에 어려움이 있다. 이 연구에서는 지진피해를 받은 건물에 지진피해로 인한 기존 기둥의 연성확보를 위해서 유리섬유시트(glass fiber sheet)로 래핑을 함과 동시에 기존 철골 X-브레이싱 내진보강법에 비교해서 경량의 고강도 재료로 보강 후 추가적인 중량증가가 거의 없으며, 브레이싱 압축 좌굴거동에 자유로운 탄소섬유 앵커 X-브레이싱공법(carbon fiber X-brace)을 조합한 경제적이며 효과적인 새로운 내진보강법(GFS-CFXB)을 제안하였다. 이 연구에서 제안한 GFS-CFXB공법의 유용성을 검증할 목적으로 지진피해를 받은 골조를 대상으로 반복가력에 의한 구조실험을 실시하여 내진성능 및 내진보강 효과를 검증하였다.

51 mm 대구경 철근을 사용한 외부 보-기둥 접합부의 정착상세별 구조성능 평가 (Structural Performance of Beam-Column Connections Using 51 mm Diameter with Different Anchorage Details)

  • 김정엽;정형석;천성철;김인호;최창식
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.201-208
    • /
    • 2017
  • 외부 보-기둥 접합부에서는 철근정착을 위해 갈고리철근 사용하고 있으며, 철근과밀배근 해소와 시공작업의 어려움으로 확대머리철근의 사용이 증가하고 있다. SD600 51 mm 확대머리철근을 사용할 경우 ACI318-14 및 KCI2012기준에서 사용을 제한하고 있다. 이번 연구에서는 외부 보-기둥 접합부 내에 고강도 대구경 철근의 확대머리 철근의 사용이 가능하도록 실험 60 MPa, 80 MPa 콘크리트강도로 제작된 실험체의 정착상세별 구조성능을 평가하였다. 모든 실험체에서는 보의 휨항복파괴가 발생하였으며, 실험체의 모멘트-변위 곡선에서 비슷한 양상을 보였다. 다른 실험체보다 갈고리가 한쪽방향으로 배근한 실험체에서는 갈고리철근 배근방향에 의해 전단저항능력이 달라지므로 3.5%변위비 이후에 부착응력 감소가 더 크게 나타났으며, 전단변형능력도 더 크게 나타났다. 실험체의 내진성능을 확인하기 위하여 ACI374.1-05기준과 비교하였으며, 실험결과 충분한 내진성능을 확보하였다. 이를 통하여 외부 보-기둥 접합부에서 SD600, 51 mm 확대머리철근의 사용이 가능한 것으로 판단된다.

보강재의 강성도를 고려한 연약지반 표층처리공법 지지력 산정방법에 관한 연구 (Characteristics of Settlement for Non-woven Geotextile through Cyclic Loading Model Test)

  • 함태규;서세관;조삼덕;양기석;유승경
    • 한국지반신소재학회논문집
    • /
    • 제8권2호
    • /
    • pp.11-20
    • /
    • 2009
  • 본 연구는 국내의 초연약지반에 적용 가능한 표층보강재를 이용한 연약지반 표층처리공법을 정립시키기 위한 기초적 연구로서 표층처리공법 지지력 산정방법을 제안하는 것을 목적으로 하고 있다. 이를 위하여 직포, 지오그리드, 강봉(대나무 대채재료)을 이용한 보강재의 단부 구속조건을 완전구속, 부분구속(3종류)으로 한 21 종류의 실내모형실험을 수행하였다. 또한 실험결과를 이용해 보강재의 강성도가 지지력효과에 미치는 영향을 고려한 지지력 산정방법을 제안하였다.

  • PDF

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

316L 시험원통의 열라체팅 구조시험에 관한 연구 (A Study on Thermal Ratcheting Structure Test of 316L Test Cylinder)

  • 이형연;김종범;구경회
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.243-249
    • /
    • 2001
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to $550^{\circ}$ and the temperature differences of about $500^{\circ}C$. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests.

  • PDF

맞대기 이음 용접의 피로수명에 베벨 각도가 미치는 역할 (Role of Bevel Angles Influenced on the Fatigue Life of Butt-welded Joints)

  • 박지환;한창완;정승빈;박성훈
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.141-147
    • /
    • 2014
  • This study aims to investigate the influence of bevel angles on the fatigue life of V-groove butt-welded joints with back-plates made by SM490A steel material, generally used for excavators, because changes in the geometry, material and surface properties of welded regions affect the fatigue life of welded structures. Butt type test specimens were prepared by the $CO_2$ welding of rolled steel plates (SM50A steel) with a thickness of 13.5 mm at a welding speed of 30 cm/min and these Butt type test specimens had two different groove angles, which are $40^{\circ}$ (A type) and $30^{\circ}$ (B type). In order to investigate differences in fatigue life between two types, 4-point bending fatigue tests were conducted with a stress ratio of R=0.1 under the cyclic loading environment at a frequency of 5 Hz at room temperature. The fatigue life of A type specimens was approximately 7% higher than that of B type specimens. The stress concentration factors calculated by finite element analysis were 2.16 for A type and 2.25 for B type, whose difference was caused by the influence of the back-plates of butt-welded structures. The current results could provide important guidelines to determine the V-groove angle of butt-welded joints with a satisfactory fatigue life, although under severe operating conditions.

골판지 적층재와 EPS 사이의 압축거동에 대한 실험적 연구 (Experimental Study on Compression Behavior between Multi-layered Corrugated Structure and EPS Packaging Materials)

  • 박종민;최원식;김종순
    • 한국산업융합학회 논문집
    • /
    • 제23권1호
    • /
    • pp.83-91
    • /
    • 2020
  • The evaluation of the compression behavior of the cushioning material is of importance to achieve appropriate packaging design. In order to change packaging design from polymeric-based to more eco-friendly cellulose-based nire effectively, comparative study on the compression behavior between these two packaging materials is crucial. In this study, the stress-strain behavior, hysteresis loss, and response characteristics for cyclic loading were analyzed through compression tests on multi-layered corrugated structure (MLCS) and expanded polystyrene (EPS) packaging materials. MLCS produced in Korea is produced by winding a certain number of single-faced corrugated paperboard, and the compression behavior of this material was turned out to be 6 stages: elastic stage, first buckling stage, sub-buckling stage, densification stage, last buckling stage and high densification stage. On the other hand, EPS's compression behavior was in 3 stages: linear elastic stage, collapse plateau, and densification stage. The strain energy per unit volume (strain energy density) of MLCS did not differ depending on the material thickness, but it showed a clear difference depending on the raw material and flute type. Hysteresis loss of MLCS ranged from 0.90 to 0.93, and there were no significant differences in the raw material and flute type. These values were about 5 to 20% greater than the hysteresis of the EPS (about 0.78 to 0.87).

X-가새형 탄소섬유케이블을 이용한 중·저층 철근콘크리트 건물의 내진보강법 개발 (A Development of Seismic Rehabilitation Method of RC Buildings Strengthened with X-Bracing Using Carbon Fiber Composite Cable)

  • 이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.1-9
    • /
    • 2014
  • 본 연구에서는 기존 강재브레이스 내진보강법이 가지는 좌굴문제 등 단점을 극복할 수 있는 중 저층 철근콘크리트 건축물에 효과적으로 적용할 수 있는 새로운 내진보강법을 개발하였다. Carbon Fiber Composite Cable (CFCC)을 이용하여 건축물 골조 외부에 X자 형태로 내진보강을 실시하고, 상부 및 하부 보 양 단부에 CFCC X-브레이싱을 고정하기 위해서 평판 및 돌출형 나사식 접합으로 내진보강을 실시하는 내진보강법으로서, 반복하중 실험을 통하여 내진보강 효과를 규명하였다. 실험체는 비교용 비보강 골조, 평판형 및 돌출형 CFCC X-브레이싱 내진보강 골조 실험체 총 3개를 제작하였다. 실험결과, 본 연구에서 개발한 CFCC 내진보강법은 강도증진형 내진보강법으로 드러났으며, 기존 강재브레이스 보강법 대비 중량증가가 거의 없으며, 재료자체가 압축에 대한 좌굴이 없으며, 경량이므로 시공성이 매우 우수하고 중량 및 체적대비 우수한 강도가 발휘될 뿐만 아니라 특히, CFCC의 직경을 변경함으로서 내진보강 목적 (강도 보강량)에 대응하여 내진성능을 쉽게 변화시킬 수 있는 장점이 있다.

내진보강된 치장조적벽의 파괴특성과 전단강도 (Shear Strength and Failure Mode of Architectural Masonry Walls)

  • 진희종;한상환;박영미
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.89-92
    • /
    • 2008
  • 본 연구는 조적조로 구성된 치장벽체의 전단거동에 관한 연구이다. 치장조적벽체의 내진보강상 세를 소개하였으며, 본 연구에서 개발한 내진상세를 적용하여 전단거동을 평가하였다. 실험체는 비보 강조적벽(URM) 1개 보강조적벽(RM) 3개로 구성하였으며, 준정적 실험을 수행하였다. 비보강 조적벽은 형상비와 축방향 압축력에 따라 다양한 거동 및 파괴가 일어난다. 그러나 본 연구는 조적구조와는 다른 치장조적조를 대상으로 하였으므로, 전단강도의 주요변수로 작용하는 축방향 압축력은 변수에서 제외 되었다. 실험변수로는 벽체의 보강유무와 형상비로 정하였다. 실험결과 실험체의 거동은 강체회전(Rocking)모드가 지배적으로 나타났으나, 최종파괴는 여러 파괴모드가 복합적으로 나타났다. FEMA273 에서는 면내조적벽의 전단강도식을 제시한다. 강도식은 조적벽의 거동모드에 따라 4가지로 분류되며, 그 거동모드는 강체회전(Rocking), 단부압괴(Toe-Crushing), 수평줄눈미끄러짐(Bed-Joint-Sliding), 사인장(Diagonal-Tension)파괴로 나타내고 있다. FEMA 273에 의해 전단강도를 평가한 결과 치장조적벽의 거동모드는 어느정도 예측 할 수 있었지만, 전단강도는 매우 다르게 나타났다.

  • PDF