• Title/Summary/Keyword: Cut wires

Search Result 18, Processing Time 0.021 seconds

MICROSTRUCTURE OF COMBINATION CLASP JOINTS IN REMOVABLE PARTIAL DENTURE (가철성(可撤性) 국부의치(局部義齒)에서 연합(聯合) Clasp 연결부위(連結部位)의 미세구조(微細構造))

  • Son, Han-Kee;Kim, Tae-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.123-132
    • /
    • 1984
  • To evaluate the microstructure of various combination clasp joint in removable partial denture, the auther selected framework alloys (Type IV gold alloy, Dentaurium, Ticonium 100) and wrought wires (gold alloy, Ticonium) for this study. Twelve series of combination joints were made by investment soldering technic and wrought wire embedded casting technic. All specimens were cut cross-sectionally and longitudinally, then examined with metallurgical microscope. The results were as follows; Some diffusion was observed in the properly constructed combination clasp joints. In soldered joints, empolying precious alloys were more favorable than non-precious alloys. In castion joints, assemblage of same alloy between framework and wrought wire was superior to other groups. Some impurities were observed in both joints by technical problems.

  • PDF

Experimental panoramic positioning errors for inducing condylar cutoff and superimposition of cervical vertebrae on the mandibular ramus (하악과두 잘림과 경추의 하악지 겹침을 야기하는 파노라마방사선촬영 오류)

  • Kang, Byung Cheol;Kim, Min Jong;Park, Hye Sun;Hwang, Sel Ae;Yoon, Suk Ja;Lee, Jae Seo
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.134-141
    • /
    • 2018
  • Purpose: To measure the head tilting angle creating initial condylar cut-off and to find the head position inducing the superimposition of the cervical vertebrae over the mandibular ramus on panoramic radiograph. Materials and Methods: The panoramic radiographs were taken with Didactic skull on cervical spine model (Scientific GmbH, Hamburg, Germany) using Kodak 8000c Digital Panoramic radiography. For the inherent radiolucency of the plastic skull model, radiopaque 1 mm diameter lead wires were attached along the margin of the mandibular condyle, ramus, mandibular body, cervical vertebrae, and FH plane of the skull model. For measuring the head tilting angle creating the condylar head cutoff, panoramic radiographs were taken by tilting the FH plane downward in 5 degree increments. For finding the distance between transverse process of the third cervical vertebra and gonion inducing superimposition of cervical vertebrae on the mandibular ramus, panoramic radiographs were taken by decreasing the distance in 0.5 cm increments. Result and Conclusion: The condylar cutoff began to appear when the head of skull model was tilted downward by 15o. As the head tilting angle increasing, the condylar cutoff became more prominent. The superimposition of cervical vertebrae over the mandibular ramus began to appear when the distance between the gonion and third cervical vertebra was 1.0 cm. As the distance decreasing, the superimpostion became more prominent.

  • PDF

A Study on the Development of a Work Operation Process Chart for Smart Distribution Board Fabrication (스마트 분전반 제작을 위한 작업 공정도 개발에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.15-20
    • /
    • 2017
  • This study presented the strength of the materials and parts for smart distribution board fabrication, and developed a work operation process chart for smart distribution board fabrication. This work operation process chart for smart distribution board fabrication complied with SPS-KEMC regulations, and the applicable range and object are less than 1,000 V and 1,000 Hz for the AC distribution board and less than 1,500 V for the DC distribution board. The power supply is 3 phase 4 wires ($3{\Phi}$ 4W), divided into a single phase circuit and a 3 phase circuit. In addition, the circuit was configured so that the leakage current flowing through the distribution line of the load could be monitored in real time by using the sensor module installed at the rear end of the circuit breaker. Therefore, the administrator can easily find the risk factor of the load since engineer can check the leakage current of each distribution line. In addition, if a leakage current greater than standard value flows, it is possible to generate an alarm against a short circuit and cut off the leakage current. The work operation process chart for the smart distribution board fabrication consists of the following steps: raw and subsidiary materials, sheet metal work, tube making, welding, painting, busbar fabrication, assembly and wiring, product inspection, shipment, etc. Moreover, symbols, ${\Delta}$, ${\nabla}$, ${\bigcirc}$, ${\Rightarrow}$, etc. were used according to the type of work and work progress so that workers can easily understand the progress of the work.

A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables (동파방지열선 화재 흔적분석과 발화원인 연구)

  • Lee, Jung Il;Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.

A Design of Power Line Communication system using Wavelet OFDM (Wavelet OFDM 기법을 이용한 전력선 통신 시스템 설계)

  • Moon, Ki-Tak;Kim, Joo-Seok;Jang, Dong-Won;Kim, Kyung-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11C
    • /
    • pp.871-876
    • /
    • 2010
  • Currently the development of powerline communication technology has become possible due to the high-speed communications. But the communication lines used for power line communication, not wires carrying power wiring is because when sending high-frequency wireless communication system unintentionally be influenced. To compensate for these shortcomings by using notch filters to reduce interference has been studied. Wavelet-based OFDM on the other hand by the method has been used to reduce interference. Wavelet-based OFDM has been used in the existing powerline OFDM scheme using FFT instead of the general structure of the CMFB filters to generate a signal. By doing so, subtly signals per frequency band, cut it, is to realize how efficient highways. It brought a deep filter characteristics, a flexible notch filter can be achieved without an external circuit has an advantage. In this paper, Using Wavelet OFDM powerline communication system is designed and presented the results of simulations.

A Study on the Fire Risk for Self-regulating Heating Cable (정온전선의 화재 위험성에 관한 연구)

  • Jung Hyun Lee;Si Hyun Kim;Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.3
    • /
    • pp.7-13
    • /
    • 2024
  • This study examines the physical characteristics of self-regulating heating cables caused by increased temperature and fire risk due to local degradation. A thermo hygrostat system, a convection dryer, a digital multimeter (Agilent 34465 A), NI DAQ, and the LabVIEW program were used to assess the physical properties in response to temperature fluctuations. As the temperature increases, the resistance of the self-regulating heating cable increases; however, when the critical point is exceeded, the resistance sharply decreases. A problem arises when the resistance value cannot return to its original state even though the temperature is lowered to the initial state. Moreover, when the ambient temperature rises while power is applied, the resistance value initially increases, and the flowing current decreases, maintaining a constant state. However, when the critical temperature is exceeded, the flowing current increases because of a rapid decrease in the resistance value, progressing to ignition. When the resistance value decreases because of the deterioration of one local area, the total resistance value becomes less than the initial resistance value. Therefore, the flowing current increases and an ignition problem occurs at one location where deterioration occurs. Despite the sustained flames and arcs resulting from the changes in the overall physical properties of the self-regulating heating cable and resistance variations due to local decline, the fire continued as the flowing current was lower than the operating current of the circuit breaker, failing to cut the power. In the case of self-regulating heating cables and heating wires, which are the leading causes of fires in winter, efforts are needed to ensure the need for periodic maintenance and the use of KS-certified products.

Issues in Ancient Metal Wire Inlay: A Case Study of Relics from Baekje (고대 금속 선상감 기법의 쟁점과 그 해석 - 백제 선상감 자료를 중심으로 -)

  • Choi, Gieun
    • Conservation Science in Museum
    • /
    • v.20
    • /
    • pp.13-30
    • /
    • 2018
  • Ancient metal objects with inlaid designs were mainly decorated using the wire inlay technique in which "V"- or "U"-shaped grooves were cut in a metal object and then filled with gold or silver. Previous studies on ancient metal objects featuring wire inlay generally attempted to ascertain the inlay techniques applied by examining photomicroscopes acquired during conservation treatment. However, they had limitations when examining wire inlay technique to the minute details. Wire inlay technique can be better investigated by enlarging X-ray films of relics using stereoscopic microscopy under transmitted light. The core processes of the wire inlay technique involve cutting grooves using a chisel and creating the inlay wires, but researchers hold varying opinions about the two processes. This study analyzed the entirety of the materials able to shed light on the main processes applied in Baekje wire inlay by examining X-ray films of relics through stereoscopic microscopy. This exhaustive research revealed that two types of techniques were used for wire inlay during the Baekje period. One is a plastic process of engraving dotted lines using a chisel and is found mostly in objects from the Cheonan and Gongju areas. The other is a cutting process that incises fine lines and was used mostly in relics from the Osan, Seosan, and Wanju areas. It is likely that the Baekje wire inlay techniques feature regional differences because the respective techniques were used or introduced by different groups of people.

A Study of Endothelium-dependent Pulmonary Arterial Relaxation and the Role of Nitric oxide on Acute Hypoxic Pulmonary Vasoconstriction in Rats (흰쥐 폐동맥의 내피세포의존성 혈관이완과 급성 저산소성 폐동맥수축에서 산화질소의 역할)

  • In, Kwang-Ho;Lee, Jin-Goo;Cho, Jae-Youn;Shim, Jae-Jung;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.3
    • /
    • pp.231-238
    • /
    • 1994
  • Backgroud: Since the demonstration of the fact that vascular relaxation by acetylcholine(Ach) results from the release of relaxing factor from the endothelium, the identity and physiology of this endothelium-derived relaxing factor(EDRF) has been the target for many researches. EDRF has been identified as nitric oxide(NO). With the recent evidences that EDRF is an important mediator of vascular tone, there have been increasing interests in defining the role of the EDRF as a potential mediator of hypoxic pulmonary vasoconstriction. But the role of EDRF in modulating the pulmonary circulation is not compeletely clarified. To investigate the endothelium-dependent pulmonary vasodilation and the role of EDRF during hypoxic pulmonary vasoconstriction, we studied the effects of $N^G$-monomethyl-L-arginine(L-NMMA) and L-arginine on the precontracted pulmonary arterial rings of the rat in normoxia and hypoxia. Mothods: The pulmonary arteries of male Sprague Dawley(300~350g) were dissected free of surrounding tissue, and cut into rings. Rings were mounted over fine rigid wires, in organ chambers filled with 20ml of Krebs solution bubbled with 95 percent oxygen and 5 percent carbon dioxide and maintained at $37^{\circ}C$. Changes in isometric tension were recorded with a force transducer(FT.03 Grass, Quincy, USA) Results: 1) Precontraction of rat pulmonry artery with intact endothelium by phenylephrine(PE, $10^{-6}M$) was relaxed completely by acetylcholine(Ach, $10^{-9}-10^{-5}M$) and sodium nitroprusside(SN, $10^{-9}-10^{-5}M$), but relaxing response by Ach in rat pulmonary artery with denuded endothelium was significantly decreased. 2) L-NMMA($10^{-4}M$) pretreatment inhibited Ach($10^{-9}-10^{-5}M$)-induced relaxation, but L-NMMA ($10^{-4}M$) had no effect on relaxation induced by SN($10^{-9}-10^{-5}M$). 3) Pretreatment of the L-arginine($10^{-4}M$) significantly reversed the inhibition of the Ach ($10^{-9}-10^{-5}M$)-induced relaxation caused by L-NMMA($10^{-4}M$) 4) Pulmonary arterial contraction by PE($10^{-6}M$) was stronger in hypoxia than normoxia but relaxing response by Ach($10^{-9}-10^{-5}M$) was decreased, 5) With pretreatment of L-arginine($10^{-4}M$), pulmonary arterial relaxation by Ach($10^{-9}-10^{-5}M$) in hypoxia was reversed to the level of relaxation in normoxia. Conclusion: It is concluded that rat pulmonary arterial relaxation by Ach is dependent on the intact endothelium and is largely mediated by NO. Acute hypoxic pulmonary vasoconstriction is related to the suppression on NO formation in the vascular endothelium.

  • PDF