• 제목/요약/키워드: Curve measurement

검색결과 985건 처리시간 0.026초

Load-ratio 법에 의한 SA508C-3와 알루미늄 합금의 탄소성 파괴저항 곡선평가 (Evaluation on elastic-plastic fracture resistance curve of SA508C-3 and aluminum alloy steels by load-ratio method)

  • ;윤한기;차귀준
    • 한국해양공학회지
    • /
    • 제10권2호
    • /
    • pp.98-105
    • /
    • 1996
  • A method is proposed to evaluate the elastic-plastic fracture resistance curve only with load displacement records without the crack length measurement in CT specimen. This method is based on the idea that the effect of plastic deformation and the crack growth can be measured only by using a load-displacement record. If we know the reference-load curve representing the hardening of specimen, then the crack extension can be calculated by the elastic compliance determined from the load ratio. The results of this proposed method were compared to those of the elastic-plastic fracture resistance curve for the ASTM standard unloading compliance method. The experimental results for two kinds of ductile materials showed that the proposed method well simulates the material J-R curves. This method is currently applied for CT specimens. but it can be extended to the other specimen geometries.

  • PDF

3차원 인체 측정치들을 이용한 중년 여성의 유방 형태에 따른 유형 (Classification of Middle Aged Women's Breast Shapes Using 3D Body Measurement Data)

  • 이현영;홍경희
    • 한국의류학회지
    • /
    • 제34권3호
    • /
    • pp.385-392
    • /
    • 2010
  • The breast types of middle-aged women of 80A (formerly 80B) size were classified through a 3D scanned nude body. Thirty seven measurements including the radius of curvature, surface area, volume, surface length, and breast displacements were used as input variables. We extracted five main factors through the factor analysis of the measurements and classified 36 subjects into 3 clusters through the cluster analysis. As a result of the factor analysis, the size of the breast, breast sag, the curvature of the inner and the outer breast curve, the width of the breast, and the nipple direction were found as the main factors. For the results of the classification of breast types, Cluster 1 was characterized by narrow breast width and unsymmetrical under the breast curve, whereas Cluster 2 was a wide and sagged shape. Cluster 3 was classified into big breast volume and symmetrical under-breast curve. The results are useful to the product development of high quality brassieres which reflect the 3D characteristics of breast types of middle-aged women.

Compensation of Probe Radius in Measuring Free-Formed Curves and Surfaces

  • Lisheng Li;Jung, Jong-Yun;Lee, Choon-Man;Chung, Won-Jee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권3호
    • /
    • pp.20-27
    • /
    • 2003
  • Compensation of probe radius is required for accurate measurement in metal working industry. Compensation involves correctly measuring data on the surface in the amount of radius of the touch probe with a Coordinate Measuring Machine (CMM). Mechanical parts with free-formed curves and surfaces are complex enough so that accurate measurement and compensation are indispensable. This paper presents necessary algorithms involved in the compensation of the probe radius for free-formed curves and surfaces. Application of pillar curve is the focus for the compensation.

머신 비전을 활용한 재료 변형 측정 기술 개발 (Development of Material Deformation Measurement System using Machine Vision)

  • 목은빈;정완진;이창환
    • 소성∙가공
    • /
    • 제32권1호
    • /
    • pp.20-27
    • /
    • 2023
  • In this study, the deformation of materials was measured using the video and tracking API of OpenCV. Circular markers attached to the material were selected the region of interests (ROIs). The position of the marker was measured from the area center of the circular marker. The position and displacement of the center point was measured along the image frames. For the verification, tensile tests were conducted. In the tensile test, four circular markers were attached along the longitudinal and transverse directions. The strain was calculated using the distance between markers both in the longitudinal and transverse direction. As a result, the stress-strain curve obtained using machine vision is compared to the stress-strain curve obtained from the DIC results. RMSE values of the strain from the machine vision and DIC were less than 0.005. In addition, as a measurement example, a bending angle and springback measurement according to bending deformation, and a moving position measurement of a punch, a blank holder, and a die by time change were performed. Using the proposed method, the deformation and displacement of the materials were measured precisely and easily.

Load Ratio 해석에 의한 알루미늄 5083 합금 용접부의 J-R곡선 평가 (Evaluation of J-R Curve for Aluminum 5083 Alloy Weldment by Load Ratio Analysis)

  • 윤한기;김연겸
    • Journal of Welding and Joining
    • /
    • 제15권4호
    • /
    • pp.178-186
    • /
    • 1997
  • The purpose of this study is to evaluate the J-R curve characteristics for the 5083 aluminum alloy weldment by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agrees well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The exponential correlation of the J-R curve for the 5083 aluminum alloy base metal by the load ratio analysis is J = 93.88 ${\Delta}{\alpha}^{0.375}$. That for the weld metal and HAZ is J = 69.87 ${\Delta}{\alpha}^{0.389}$ and J = 70.59 ${\Delta}{\alpha}^{0.359}$ respectively. The J-R curve obtained by the ASTM unloading compliance method is overpredicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load displacement curve without particular crack measurement equipment.

  • PDF

The prognostic value of median nerve thickness in diagnosing carpal tunnel syndrome using magnetic resonance imaging: a pilot study

  • Lee, Sooho;Cho, Hyung Rae;Yoo, Jun Sung;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • 제33권1호
    • /
    • pp.54-59
    • /
    • 2020
  • Background: The median nerve cross-sectional area (MNCSA) is a useful morphological parameter for the evaluation of carpal tunnel syndrome (CTS). However, there have been limited studies investigating the anatomical basis of median nerve flattening. Thus, to evaluate the connection between median nerve flattening and CTS, we carried out a measurement of the median nerve thickness (MNT). Methods: Both MNCSA and MNT measurement tools were collected from 20 patients with CTS, and from 20 control individuals who underwent carpal tunnel magnetic resonance imaging (CTMRI). We measured the MNCSA and MNT at the level of the hook of hamate on CTMRI. The MNCSA was measured on the transverse angled sections through the whole area. The MNT was measured based on the most compressed MNT. Results: The mean MNCSA was 9.01 ± 1.94 ㎟ in the control group and 6.58 ± 1.75 ㎟ in the CTS group. The mean MNT was 2.18 ± 0.39 mm in the control group and 1.43 ± 0.28 mm in the CTS group. Receiver operating characteristics curve analysis demonstrated that the optimal cut-off value for the MNCSA was 7.72 ㎟, with 75.0% sensitivity, 75.0% specificity, and an area under the curve (AUC) of 0.82 (95% confidence interval [CI], 0.69-0.95). The best cut off-threshold of the MNT was 1.76 mm, with 85% sensitivity, 85% specificity, and an AUC of 0.94 (95% CI, 0.87-1.00). Conclusions: Even though both MNCSA and MNT were significantly associated with CTS, MNT was identified as a more suitable measurement parameter.

수로부 계측정보 기반 농업용 저수지의 관개용수 공급량 평가 (Evaluation of the Irrigation Water Supply of Agricultural Reservoir Based on Measurement Information from Irrigation Canal)

  • 이재남;노재경;강문성;신형진
    • 한국농공학회논문집
    • /
    • 제62권6호
    • /
    • pp.63-72
    • /
    • 2020
  • With the implementation of integrated water management policies, the need for information sharing with respect to agricultural water use has increased, necessitating the quantification of irrigation water supply using monitoring data. This study aims to estimate the irrigation water supply amount based on the relationship between the water level and irrigation canal discharge, and evaluate the reliability of monitoring data for irrigation water supply in terms of hydrology. We conducted a flow survey in a canal and reviewed the applicability of the rating curve based on the exponential and parabolic curves. We evaluated the reliability of the monitoring data using a reservoir water balance analysis and compared the calculated results of the supply quantity in terms of the reservoir water reduction rate. We secured 26 readings of measurement data by varying the water levels within 80% of the canal height through water level control. The exponential rating curve in the irrigation canal was found to be more suitable than the parabolic curve. The irrigation water supplied was less than 9.3-28% of the net irrigation water from 2017 to 2019. Analysis of the reservoir water balance by applying the irrigation water monitoring data revealed that the estimation of the irrigation water supply was reliable. The results of this study are expected to be used in establishing an evaluation process for quantifying the irrigation water supply by using measurement information from irrigation canals in agricultural reservoirs.

플로우 펌프기법을 이용한 포천지역 화강 풍화토의 함수특성곡선 (Soil-Water Characteristic Curve of Weathered Granite Soils in Pocheon Area using Flow Pump Technique)

  • 이강일;이준용;백원진
    • 한국농공학회논문집
    • /
    • 제51권1호
    • /
    • pp.11-20
    • /
    • 2009
  • Flow pump technique was used in order to determine the soil-water characteristic curve of weathered granite soils in Pocheon area. This technique enables measurement to be more convenient and accurate as it is based on the CU condition of triaxial compression test. Besides, it is also able to measure dry and moisture curves continuously since the test is controled by means of a computer automatically. In this study, not only a hydraulic conductivity of weathered granite soils at fully saturated state in Pocheon area, but also a soil-water characteristic curve throughout unsaturate flow tests were determined. In addition, Brooks and Corey's model and Genuchten's model were used to simulate the soil-water characteristic curve. On the basis of the simulation an unsaturate hydraulic conductivity was predicted.

원자로 압력용기강 및 Al 합금재의 J-R곡선평가시 Load Ratio 해석의 유효성 검토 (Validity Examination on Evaluation of J-R Curve in the Nuclear Reactor Pressure Vessel Steels and Aluminum Alloys by Load Ratio Analysis)

  • 윤한기;우대호;김연겸;차귀준
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.80-90
    • /
    • 1997
  • The purpose of this study is to evaluate the validity examination of the J-R curve characteristics for the nuclear reactor pressure vessel steels and Al alloys by the load ratio analysis. The results of the load ratio analysis are compared with those of the J-R curve which are obtained by the ASTM unloading compliance method. The crack length calculated by the load ratio analysis is agree well with the measured final crack length. The slope of the exponential J-R curve estimated by the load ratio analysis is slightly smaller than that by the ASTM unloading compliance method. The J-R curve obtained by the ASTM unloading compliance method is over-predicted and should be offsetted due to the initial negative crack. On the other hand, the load ratio analysis method can evaluate the J-R curve by only load-displacement curve without particular crack measurement equipment.

  • PDF

Experimental and Simulated Efficiency of a HPGe Detector in the Energy Range of $0.06{\sim}11$ MeV

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.234-242
    • /
    • 2003
  • The full energy peak efficiency of a hyper pure germanium (HPGe) detector was calibrated in a wide energy range from 0.06 to 11 MeV. Both the experimental technique and the Monte Carlo method were used for the efficiency calibration. The measurement was performed using the standard radioisotopes in the low energy region of $60{\sim}1408$ keV, which was further extended up to 11 MeV by using the $^{14}N(n,r)\;and\;^{35}Cl(n,r)$ reactions. The GEANT Monte Carlo code was used for efficiency calculation. The calculated efficiency had the same dependency on the r-ray energy with the measurement, and the discrepancy between the calculation and the measurement was minimized by fine-tuning of the detector geometry. From the calculated result, the efficiency curve of the HPGe detector was reliably determined particularly in the high energy region above several MeV, where the number of measured efficiency points is relatively small despite the wide energy region. The calculated efficiency agreed with the measurement within about $7\%$. In addition to the efficiency calculation, the origin of the local minimum near 600 keV on the efficiency curve was analyzed as a general characteristics of a HPGe detector.