• 제목/요약/키워드: Curtain Wall

검색결과 239건 처리시간 0.025초

A Study on Robotic-Laser-Welding Performance for Application of Non-Standard Steel Curtain Wall Members (비규격 스틸커튼월 부재의 적용을 위한 로봇 레이저용접 성능에 관한 연구)

  • Na, Sangho;Lee, JangHyun;Park, YoungMi;Kim, SungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.4-5
    • /
    • 2021
  • In irregular curtain walls, the nominal stress required for each member varies greatly depending on the shape, so it is inefficient to design members based on the maximum required stress. Then, built-up members are absolutely necessary, but built-up members manufactured by Manpower-welding cannot be constructed in an irregular curtain wall building because it' not precise. In order to address the problems, this paper presents why Robotic-laser-welding should be used in irregular curtain walls using Gwanggyo Galleria Department Store involving 3D printing as an example. Results verify the performance of Robot-Laser-Welding as an efficient solution for precise steel curtain wall members.

  • PDF

Economic Evaluation Method by Design Method ASD and LRFD of Aluminum Curtain wall (알루미늄 커튼월의 ASD/LRFD설계방법에 따른 경제성 평가 방법)

  • Moon, Sang-Deok;Ock, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.16-17
    • /
    • 2014
  • The curtain wall construction applied on high-rise building facades in Korea became generalized, but specialty of the CMr(Construction Manager) who needs to perform economical project management with specialty in the curtain wall construction is still lacking. Therefore, this study analyzed the structure design standard of the curtain wall, researched economical design alternatives. Based on the research results, if the ratio of dead load against wind load is less than 0.1256, LRFD will be more economical.

  • PDF

A Study on the Development of High-rise Curtain Wall Thermal Analysis Program (초고층 커튼월 외피 열성능해석 프로그램 개발에 관한 연구)

  • No, Sang-Tae;Kim, Kang-Soo;Chung, Jin-Se
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제19권1호
    • /
    • pp.10-18
    • /
    • 2007
  • The purpose of this study is to develop an user-friendly computer program which can analyze the thermal performance of high-rise curtain wall. In this study, the sub-routines for FVM SOLVER, HIGH-RISE CONDITION CALCULATION, AUTOMATIC SPECIFICATION BOUNDARY/MESH, MATERIAL DATABASE, and GRAPHICAL CONDENSATION/U-FACTOR OUTPUT were developed by using Visual Basic. The curtain wall heat conduction simulation results of program showed good agreement with those of FLUENT and THERM. The minimum and maximum relative error rates were 3.17 and 9.68% compared to other software.

A Study on the Analysis of Insulation Performance according to Curtain Wall Type and Insulation Material Form (커튼월 형태 및 단열재 형상에 따른 단열성능 분석에 관한 연구)

  • You, Nam-Gyu;Hong, Sang-Hun;Kim, Hae-Na;Seo, Eun-Seok;Kim, Bong-Joo;Jung, Ui-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.165-166
    • /
    • 2019
  • Curtain wall means a non-bearing wall that forms the outer walls of a building to divide the exterior and interior space. The increased use of curtain walls is diverse, including structural safety, watertightness, and wind pressure. As the government's energy conservation policy and the aim of zero-energy houses, the importance of heat reduction is also greatly increased. So, the study of monotony is constantly being conducted. Thus, in this study, insulation performance was analyzed through simulation according to the shape of curtain wall and the shape of insulation inside, and the purpose of this study was to provide basic data on the application of insulation criteria by energy saving design of buildings.

  • PDF

A study on the characteristic and designing condition of Curtain wall (Curtain Wall의 특성 및 설계조건에 관한 연구)

  • Jeong, Eul-Gyu;Im, Chil-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • 제4권3호
    • /
    • pp.125-131
    • /
    • 2004
  • Nowadays, it seems we are in the high time of construction design because development of construction technology widen the option of construction exterior closing materials and deepen the high-tech construction method with all various materials. When we see the flow of construction market, the mainstream is the high-rise intelligent building, which makes the best use of the small midtown area efficently. Therefore, Alum curtain wall is becoming the main material of exterior construction, the concept of which is changing from just a simple window frame to an outer wall which has comprehensive function and capability. As we think of the importance of Curtain wall as a comprehensive outer wall, We should do thorough technical examination and verification at the stage of construction design and plan of carrying out construction.

Advanced Structural Silicone Glazing

  • Kimberlain, Jon;Carbary, Larry;Clift, Charles D.;Hutley, Peter
    • International Journal of High-Rise Buildings
    • /
    • 제2권4호
    • /
    • pp.345-354
    • /
    • 2013
  • This paper presents an advanced engineering technique using finite element analysis to improve structural silicone glazing (SSG) design in high-performance curtain wall systems for building facade. High wind pressures often result in bulky SSG aluminum extrusion profile dimensions. Architectural desire for aesthetically slender curtain wall sight-lines and reduction in aluminum usage led to optimization of structural silicone bite geometry for improved stress distribution through use of finite element analysis of the hyperelastic silicone models. This advanced design technique compared to traditional SSG design highlights differences in stress distribution contours in the silicone sealant. Simplified structural engineering per the traditional SSG design method lacks accurate forecasting of material and stress optimization, as shown in the advanced analysis and design. Full scale physical specimens were tested to verify design capacity in addition to correlate physical test results with the theoretical simulation to provide confidence of the model. This design technique will introduce significant engineering advancement to the curtain wall industry and building facade.

PV module manufacture for application of Building Integrated photovoltaic system (건물일체형 태양광발전시스템(BIPV) 적용을 위한 태양전지모듈 제조)

  • Kang Gi-Hwan;Yu Gwon-Jong;Han Deuk-Young;An Hyung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1465-1467
    • /
    • 2004
  • In this paper, deduced manufacturing condition of glass/glass curtain wall module and metal curtain wall module. From the results. lamination condition of glass/glass curtain wall module deduced optimum in pumping $time-120^{\circ}C$ 23min, slow $press-120^{\circ}C$. 300mmHg. 3min. standard $press-120^{\circ}C$. 200mmHg. 0.5min. fast $press-120^{\circ}C$. 100mmHg. 0.3min and $curing-140^{\circ}C$, 6min, and lamination condition of metal curtain wall module deduced optimum in pumping $time-120^{\circ}C$. 8min, slow $press-120^{\circ}C$, 700mmHg. 0.5min, standard $press-120^{\circ}C$, 600mmHg, 0.5min. fast $press-120^{\circ}C$, 100mmHg. 1.5min and $curing-140^{\circ}C$. 6min. This time. power uniformity of glass/glass curtain wall module and metal curtain wall module showed each ${\pm}2.7\%,\;{\pm}2.12\%$.

  • PDF

A Study on the History of Technology in Korean Modern Architecture (한국 현대건축의 기술역사에 관한 연구)

  • Jung, In-Ha;Kim, Jin
    • Journal of architectural history
    • /
    • 제9권3호
    • /
    • pp.51-69
    • /
    • 2000
  • This study tries to analyze the development of architectural technologies appeared in several tall buildings and large spatial structures from 1955 to 1999 in Korea. We suppose that these buildings represent the development of technology in Korean modern architecture. By the detailed analysis of these buildings, we can arrive at a conclusion as such; During the years 1955-1999, there existed a great changement in the eighties. We can find this fact very well in the domain of structural system and curtain wall system. In large spatial structures, the structural-system of shell and steel truss dome was replaced by that of space frame, space truss and cable truss with membrane. In tall building, the structural system of rigid frame and shear wall was replaced by tubular system, core and outrigger system. Korean architects introduced the aluminum curtain wall in the sixties, but its low technological level caused many problems in reality. Therefore, precast concrete curtain wall appeared from seventies as the main method for an outer wall in tall building. With the augmentation of height after 1980, PC curtain wall was replaced by the aluminum curtain wall of unit type and structural glass wall system. These systems help to stress the transparency in a tall building.

  • PDF

A Study on the Development of the Structural Performance Evaluation Manual of the Skyscrapers Curtain Wall Systems for Construction Managers (초고층건축 알루미늄커튼월 구조설계검토 프로세스와 매뉴얼 개발에 관한 연구: 멀리언과 트랜섬을 중심으로)

  • Cho, Ye-Won;Lee, Min-Cheol;Ock, Jong-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • 제10권3호
    • /
    • pp.92-101
    • /
    • 2009
  • The purpose of this study was to develop the curtain-wall structure design evaluation manual that can easily examine the curtain-wall structural members (Mullion and Transom) stability from the position of the construction managers. Through analyzing the structural design reports in the previous studies and interview with industry experts, the curtain-wall structural member design process was elicited. The manual, which consists of Microsoft Excel-based work sheet and its manual, was applied to a real curtain-wall design project to make sure its usability. A workshop with three curtain-wall experts and three construction managers was conducted to identify pros and cons of the manual, thereby enhancing its applicability in the future.

Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior (ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구)

  • Kim, Young-Ho;Lee, Yong-Soo
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • 제13권4호
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.