• Title/Summary/Keyword: Current test

Search Result 7,172, Processing Time 0.041 seconds

Zinc Loss Detection in ACSR Power Lines using the Removable Type of Eddy Current Sensor (착탈형 와류센서를 이용한 ACSR전선의 아연손실량 검출)

  • Jang, T.I.;Jo, S.B.;Kang, J.W.;Kang, Y.W.;Yang, B.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1963-1965
    • /
    • 2000
  • This paper deals with a problem of detecting the inner corrosion of the ACSR(Aluminum Conductor Steel Reinforced) power lines using a detector which consists of an ECT(Eddy Current Test) sensor, a constant current service, a signal processing unit, and a RF transmitter/receiver unit. The detector runs on the ACSR transmission line and inspects the corrosion of the conductor using the technic of the nondestructive eddy current test. The experimental result shows this detector can efficiently find the zinc loss in ACSR power lines.

  • PDF

Equal Current Distribution in Parallel Resistive SFCL Using SIPT (SIPT를 이용한 병렬 저항형 한류기의 평형전류분배)

  • 심정욱;최용선;김혜림;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.109-112
    • /
    • 2003
  • Small impedances in the superconducting parallel circuits cause unequal distribution of the currents in the circuits. This results in quenches or losses in some superconducting parts and decrease of total transport current. This paper presents the fabrication and test results of a superconducting multi- interphase transformers (SIPT) for equal current distribution in superconducting parallel circuits. The secondary loop configuration with air core SIPT seems to be the most efficient one for the SFCL. Test results show that the SIPT can effectively make the current distribution uniform in Parallel circuits that have unequal resistances.

  • PDF

Experimental Characteristics Examination of a Hybrid-Type Supercapacitor (하이브리드형 슈퍼커패시터의 실험적 특성 규명)

  • Jeong, Kyuwon;Shin, Jaeyoul
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.4
    • /
    • pp.307-311
    • /
    • 2016
  • Several types of supercapacitors have been developed for energy storage systems. Among them, the hybrid type has advantages such as a large capacitance per weight compared with the electric double-layer capacitator type. In this study, constant current charging and discharging tests were conducted for recently developed hybrid-type supercapacitors. Based on the experimental results, the capacitance and equivalent series resistance were obtained. The capacitance was larger than the designed capacitance at a low current but became small at a high current. In addition, the capacitance depended on the cell voltage. These results can be used to design an energy storage system.

Study of requirements for protective current transformers for transient performance (보호용 변류기의 과도성능에 대한 고찰)

  • Jung Heung-Soo;La Dae-Ryeol;Kim Sun-Koo;Roh Chang-il;Kim Won-Man;Lee Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.839-841
    • /
    • 2004
  • IEC 60044-6 (Requirements for protective current transformers for transient performance) was established to Korea Standard (KS C IEC 60044-6 ; Instrument transformers Part 6 ; Requirements for protective current transformers for transient performance) in December 11, 2003. In this paper, requirements, test items and test methods protective current transformers for transient performance.

  • PDF

Quantitative vibratory sense measurement systems of a diabetic neuropathy (당뇨병성 신경병증의 정량적 진동 감각 측정 시스템)

  • Ryu, Bong-Jo;Kim, Youngshik;Koo, Kyung-Wan
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.615-620
    • /
    • 2018
  • Evaluation of clinical usefulness of current perception threshold test and vibration sense perception threshold test in diagnosing the diabetic poly-neuropathy patients is one of the diagnosis methods for diabetic poly-neuropathy. Up to the present, some diagnostic methods were used for diabetic poly neuropathy patients. For example, there are neuropathy impairment score test of lower limbs, nerve conduction test, cooling detection threshold test, heat-pain threshold test and so on. However, most of the above tests require very expensive cost and take a lot of time in test. In this paper, a new apparatus estimating vibration sense ability is introduced. For this purpose, the VCM(voice coil motor) stimulating patient's peripheral nerve and current amplifier were manufactured. Also, softwares sensing and driving the vibration detection threshold test in order to measure the quantitative vibration sensory levels in diabetic poly-neuropathy patients were developed.

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

Manufacture and Tests of Cryostat for Micro SMES (Micro SMES용 크라이오스테l트 제작 및 특성평가)

  • 조전욱;심기덕;하홍수;김해종;성기철;권영길;고득용;염한길;류충식
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.44-48
    • /
    • 2001
  • SMES consists of Superconducting magnet, a power converter, a cryostat and HTS current leads The prototype cryostat with HTS current leads and refrigerators was designed and manufactured for developing micro SMES. The temperature rise under dc current in HTS current leads was measured. The performances of helium boil-off and mechanical stress were evaluated during transfer and vibration tests. The results will be used to develope the micro-SMES system.

  • PDF

Design and Development of 200 W Power Converter (200 W급 LED 구동용 전원장치 설계 및 개발)

  • Kim, HyungJoong;Joung, Gyubum
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.242-243
    • /
    • 2012
  • In this paper, 200 W power supply for LED driver has been designed, analyzed, simulated and tested. Input AC voltage of 100VAC-240VAC was converted to DC voltage by high power factor converter. Output voltage was controlled, and output current was controlled by constant current when output current was reached to LED maximum rated current. By simulation and experimental test, voltage and current control and high power factor characteristics are verified.

  • PDF

Analysis of the Melting Characteristics of a Blade Type Fuse Used for Vehicles Due to Overload (과부하에 따른 차량용 블레이드형 퓨즈의 용단특성 해석)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.38-43
    • /
    • 2010
  • The purpose of this study is to secure the basis for judgment on the cause of an accident by analyzing the melting characteristics of a blade type fuse used for vehicles due to overload. In order to increase the reliability of the test, it was conducted by connecting the electrical system with conditions similar to those of an actual vehicle to apply the load. Carbonization pattern experiment of fuse by outside flame applied Korean Standard (KS). The fuse melted by the overcurrent showed a smooth cross-section while the test terminals, clear plastic body, etc., burnt out by the external flame was badly deformed. When 185% of the rated current (27.8A) was applied to a cable of 15A rated current onto which an over-capacity fuse (20A) was installed, the fuse melting time was 217 seconds. In addition, when a load current of 28.8[A] (139%) was applied, the fuse's test terminal and terminal blade were not burnt out although foam was observed on some parts of the plastic body. When a load capacity of 28.2[A] (141%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melting time was approximately 10 seconds. When a load current of 35.8[A] (119%) was applied, the fuse's test terminal and terminal blade were not burnt out, although some parts of the plastic body was swelled. However, it was observed that the switch terminal melted if approximately six minutes lapsed under such conditions. When a load capacity of 39.4[A] (131%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melted in approximately 69 seconds, and the test terminal and terminal blade were not burnt.

Introduction to Daegwallyeong Wind Turbine Test Site and Field Test Study (대관령 풍력실증단지 및 실증연구 소개)

  • Yoo Neung-Soo;Nam Yun-Soo;Lee Jung-Wan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.5-8
    • /
    • 2005
  • This paper aims to introduce the Daegwallyeong wind turbine test site which is the first official wind turbine test site in Korea. The current status of test site, the characteristics, the projects performed and future plan of this test site are described. The results of wind condition measurements and monitoring system established by the Kangwon National University are presented. The importance of field test is also commented.

  • PDF