• 제목/요약/키워드: Current source inverter

검색결과 557건 처리시간 0.036초

단전원 듀얼 인버터의 데드타임으로 인한 영상전류 억제 방법 (Suppression of Zero Sequence Current Caused by Dead-time for Dual Inverter With Single Source)

  • 윤범렬;김태형;이준희;이준석
    • 전력전자학회논문지
    • /
    • 제27권2호
    • /
    • pp.126-133
    • /
    • 2022
  • This study proposes a suppression of zero sequence current (ZSC), which is caused by zero sequence voltage (ZSV) for a dual two-level inverter with single DC bus. Large output voltages enable the dual inverter with single DC bus to improve a system efficiency compared with single inverter. However, the structure of dual inverter with single DC bus inevitably generates ZSC, which reduces the system efficiency and causes a current ripple. ZSV is also produced by dead time, and its magnitude is determined by the DC bus and current direction. This study presents a novel space vector modulation method that allows the instantaneous suppression of ZSC. Based on a condition where a switching period is twice a sampling (control) period, the proposed control method is implemented by injecting the offset voltage at the primary inverter. This offset voltage is injected in half of the switching period to suppress the ZSC. Simulation and experiments are used to compare the proposed and conventional methods to determine the ZSC suppression performance.

소규모 계통연계형 태양광 시스템의 최적제어에 대한 연구 (Research about most suitable control of small scale system link type photovoltaic system)

  • 황락훈;장은성;남우영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.238-243
    • /
    • 2003
  • The solar cells should be operated at the maximum power point because its output characteristics are greatly fluctuated on the variation of insolation, temperature and load. The output power of solar cell is DC, therefore it is necessary to install an inverter among electric power converts. The inverter have to supply a sinusoidal current and voltage to the load and the interactive utility line. In the paper, the proposes a photovoltaic system designed with a step up chopper and single phase PWM voltage source inverter. Synchronous signal and control signal was processed by microprocessor for stable modulation. The step up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature because solar cell has typical dropping character. The single phase PWM voltage source inverter consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be developed continuously by connecting with the source of electric power, from 10 to $20\%$. The single phase PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. The inverter supplies an ac power with high factor and low level of harmonics to the load and the utility power system.

  • PDF

AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 라인 인터렉티브 무정전전원장치 시스템 (A Novel Three-Phase Line-Interactive UPS System having AC Line Reactor and Parallel-Series Active Filters)

  • 지준근
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 춘계학술대회
    • /
    • pp.193-197
    • /
    • 2004
  • The four-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. In this paper a novel line interactive Uninterruptible Power Supply(UPS) using the two four-leg VSCs is proposed. One VSC is in parallel with the ac link reactor of the power source side, and the other is in series with the load. The parallel four-leg voltage source inverter controls the three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series four-leg voltage source inverter compensates the line voltage and allows it to be balanced and harmonic-free. Both of the parallel and series four-leg voltage source inverters always act as independently controllable voltage sources, so that the three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulations results.

  • PDF

GTO-직류전원을 병용한 부하전류(轉流)식 전류형 인버터에 관한 연구 (A Study on the Load Commutated Current Source Inverter assisted with A GTO-DC Source Forced Commutation)

  • 목형수;설승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.591-595
    • /
    • 1991
  • The load commutated current source inverter(LCCSI) with GTO-DC source forced commutation is described in this Paper. GTO-DC source forced commutation assures the stability of commutation below critical frequency determined by output capcaitor and it also gives the oppotunity of PWM operation for reducing resonant harmonic components. he simulation results clearly show hat the proposed commutation circuit works well in the resonance phenomenon between output capacitor and machine leakage inductance.

  • PDF

인버터 구동 유도 전동기 고주파 모델링 (High Frequency Model of Inverter-fed Induction Motor)

  • 흥선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.795-797
    • /
    • 2001
  • Voltage varing Fate dv/dt which is applied to induction motor usually makes unnegligible leakage current and it flows through stator winding and motor frame. This kind of harmonic leakage current makes effect on power source and cuases electromagnetic trouble because the motor frame has earth. Therefore in this study, a high frequency induction motor model is developed and analyze the motor performance to explain the phenomena. Inverter model is also developed and is combined with the motel model to prepare the basis of the high frequency effects on inverter fed induction motor.

  • PDF

DSP를 이용한 3상 태양광 인버터의 SPWM 전력변환기술에 대한 연구 (A Study on the SPWM based Power Conversion Technology of the Three-Phase Photovoltaic Inverter Using DSP)

  • 김효성;유호성;이유정;정훈;고윤석
    • 한국전자통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1099-1106
    • /
    • 2017
  • 본 논문에서는 신재생 에너지원인 태양광 발전을 위한 3상 인버터의 전력변환기술을 연구하였다. 태양광 인버터로는 정전압 공급 방식의 전압형 인버터, 제어기법으로는 SPWM 제어기법이 채택되었다. 태양광 인버터의 SPWM 제어기로는 강력한 고속 데이터 연산능력을 가지는 DSP가 채택되었으며, 배터리의 충전에 일정량의 전류를 공급하기 위해서 태양광 컨트롤러가 사용되었다. 끝으로, DSP를 주제어장치로 하는 소용량 3상 태양광 인버터 시스템이 시험, 제작되었으며, 실험을 통해서 SPWM 기반의 전력변환기능이 검증되었다.

단상 풀 브리지 인버터를 이용한 SRM 컨버터 토폴로지 (The Converter Topology with full Bridge Inverter for the Switched Reluctance Motor Drives)

  • 장도현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.475-481
    • /
    • 2002
  • In this paper the new converter topology using single-Phase full bridge inverter for the switched reluctance motor drives is proposed. The proposed SRM drives are supplied by the AC pulse voltage source, while the conventional drives are supplied by the DC voltage source. Speed of the SRM is controlled by adjusting the frequency and the multitude of output current of inverter. The SRM using the proposed converter reduces the switching loss and the machine core loss, and has ability to pre-regulate the input voltage. The total number of power switches become fewer than another topology as a number of stator poles becomes more. Power circuit of an inverter is simpler and its volume is smaller because the module device involving several switches is used as an inverter.

A Current Dynamic Analysis Based Open-Circuit Fault Diagnosis Method in Voltage-Source Inverter Fed Induction Motors

  • Tian, Lisi;Wu, Feng;Shi, Yi;Zhao, Jin
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.725-732
    • /
    • 2017
  • This paper proposed a real-time, low-cost, fast transistor open-circuit fault diagnosis method for voltage-source inverter fed induction motors. A transistor open-circuit changes the symmetry of the inverter topology, leading to different similarities among three phase load currents. In this paper, dynamic time warping is proposed to describe the similarities among load currents. The proposed diagnosis is independent of the system model and needs no extra sensors or electrical circuits. Both simulation and experimental results show the high efficiency of the proposed fault diagnosis method.

High-Frequency Zero Current Soft Switching Inverter with Pulse Density Modulation for Induction Heated Roller

  • Kang, Shin-Chul;Mun, Sang-Pil
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.49-57
    • /
    • 2008
  • This paper presents a voltage source type half-bridge series resonant high frequency (HF) inverter for induction heated fixing roller in copy machines. This high-frequency inverter works under zero current soft switching (ZCS) commutation and has wide power regulation range due to employing a pulse density modulation (PDM) scheme. Transient and steady state operating modes of the inverter are presented in this paper together with its PDM-based power regulation system. Experimental operating performances of the developed HF-ZCS inverter as well as power losses and actual efficiency are discussed and compared with computer simulation results.

4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발 (Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor)

  • 지준근;김효성;설승기;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF