• Title/Summary/Keyword: Current pulse

Search Result 1,872, Processing Time 0.028 seconds

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe (전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법)

  • 이석훈
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • The determination of trace concentration of U, Th and Pb was carried out for chemical dating of zircon and monazite by electron microprobe. Detection limit and error range should be considered to measure characteristic X-rays of M-line from those minerals, which are low in the ionization of atom and low peak intensity in the spectrum. The element of U, Th and Pb were simultaneously measured with 3 spectrometers equipped with PET crystal to reduce a total counting time and error due to drift of instrumental operating condition. Detection limit could be improved from increase of the peak/background ratio through adjusting pulse height analyzer about 1000 mv baseline. Under permissible maximum analytical conditions, theoretical detection limit of U, Th and Pb is down to 30 ppm (99% confidence level). The analytical result was maintained at a relative error $\pm$10% ($2{\sigma}$) in 800 ppm Pb, $\pm$5% ($2{\sigma}$) in 2330 ppm U and $\pm$10% ($2{\sigma}$) in dating from a single measurement of zircon at 15 keV and 100 nA. However, for the precise dating of zircon and monazite, if it is considered a 3 $\mu\textrm{m}$ spatial resolution, <100 ppm ($3{\sigma}$) detection limit and <$\pm$10% ($2{\sigma}$) relative error, optimum analytical conditions are given as 15~20 keV accelerating voltage, 100~200 nA beam current and 300~1200 sec total counting time. To reduce material damage by high current, there is need to be up to 3~5 $\mu\textrm{m}$ of electron beam diameter, or to use arithmetic average of multiple measuring at a shorter counting time. A younger or relatively low concentration rocks can be dated chemically by lower detection limit and improved precision resulted from increase of current and measuring time.

  • PDF

17O Solid-State NMR Study of the Effect of Organic Ligands on Atomic Structure of Amorphous Silica Gel: Implications for Surface Structure of Silica and Its Dehydration Processes in Earth's Crust (유기 리간드와 비정질 실리카겔의 상호 작용에 대한 17O 고상핵자기공명 분광분석 연구: 실리카 표면 구조 및 지각의 탈수반응에 대한 의의)

  • Kim, Hyun Na;Lee, Sung Keun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.271-282
    • /
    • 2012
  • We explore the effect of removal of organic ligand on the atomic configurations around oxygen in hydroxyl groups in amorphous silica gel (synthesized through hydrolysis of $SiCl_4$ in diethyl-ether) using high resolution $^{17}O$ solid state NMR spectroscopy. $^1H$ and $^{29}Si$ MAS NMR spectra for amorphous silica gel showed diverse hydrogen environments including water, hydroxyl groups (e.g., hydrogen bonded silanol, isolated silanol), and organic ligands (e.g., alkyl chain) that may interact with surface hydroxyls in the amorphous silica gel, for instance, forming silica-organic ligand complex (e.g., Si-$O{\cdots}R$). These physically and chemically adsorbed organic ligands were partly removed by ultrasonic cleaning under ethanol and distilled water for 1 hour. Whereas $^{17}O$ MAS NMR spectra with short pulse length ($0.175{\mu}s$) at 9.4 T and 14.1 T for as-synthesized amorphous silica gel showed the unresolved peak for Si-O-Si and Si-OH structures, the $^{17}O$ MAS NMR spectra with long pulse length ($2{\mu}s$) showed the additional peak at ~0 ppm. The peak at ~0 ppm may be due to Si-OH structure with very fast relaxation rate as coupled to liquid water molecules or organic ligands on the surface of amorphous silica gel. The observation of the peak at ~0 ppm in $^{17}O$ MAS NMR spectra for amorphous silica gel became more significant as the organic ligands were removed. These results indicate that the organic ligands on the surface of amorphous silica gel interact with oxygen atoms in Si-OH and provide the information about atomic structure of silanol and siloxane in amorphous silica gel. The current results could enhance the understanding of dehydration mechanism of diverse silicates, which is known as atomic scale origins of intermediate depth (approximately, 70~300 km) earthquakes in subduction zone.

Fabrication of Virtual Frisch-Grid CdZnTe ${\gamma}$-Ray Detector (가상 Frisch-그리드를 이용한 CdZnTe 감마선 소자 제작)

  • Park, Chansun;Kim, Pilsu;Cho, PyongKon;Choi, Jonghak;Kim, Jungmin;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.253-259
    • /
    • 2014
  • Large volume of $6{\times}6{\times}12mm^3$ CdZnTe ${\gamma}$-ray detector was fabricated with CdZnTe single crystals grown by Traveling Heater Method (THM) to evaluate the energy resolution of 662 keV in $^{137}Cs$. Hole tailing effect which originated from the large mobility difference in electron and hole degrade energy resolution of radiation detector and its effects become more severe for a large volume detectors. Generally, single carrier collection technique is very useful method to remove/minimize hole tailing effect and thereby improvement in energy resolution. Virtual Frisch-grid technique is also one of single charge collection method through weighting potential engineering and it is very simple and easily applicable one. In this paper, we characterized CZT detector grown by THM and evaluated the effectiveness of virtual Frisch-grid technique for a high energy gamma-ray detector. The proper position and width of virtual Frisch-grid was determined from electric field simulation using ANSYS Maxwell ver. 14.0. Energy resolution of 2.2% was achieved for the 662 keV ${\gamma}$-peak of $^{137}Cs$ with virtual Frisch-grid CdZnTe detector.

Spinal cord stimulation in chronic pain: technical advances

  • Isagulyan, Emil;Slavin, Konstantin;Konovalov, Nikolay;Dorochov, Eugeny;Tomsky, Alexey;Dekopov, Andrey;Makashova, Elizaveta;Isagulyan, David;Genov, Pavel
    • The Korean Journal of Pain
    • /
    • v.33 no.2
    • /
    • pp.99-107
    • /
    • 2020
  • Chronic severe pain results in a detrimental effect on the patient's quality of life. Such patients have to take a large number of medications, including opioids, often without satisfactory effect, sometimes leading to medication abuse and the pain worsening. Spinal cord stimulation (SCS) is one of the most effective technologies that, unlike other interventional pain treatment methods, achieves long-term results in patients suffering from chronic neuropathic pain. The first described mode of SCS was a conventional tonic stimulation, but now the novel modalities (high-frequency and burst), techniques (dorsal root ganglia stimulations), and technical development (wireless and implantable pulse generator-free systems) of SCS are becoming more popular. The improvement of SCS systems, their miniaturization, and the appearance of new mechanisms for anchoring electrodes results in a significant reduction in the rate of complications and revision surgeries, and the appearance of new waves of stimulation allows not only to avoid the phenomenon of addiction, but also to improve the long-term results of chronic SCS. The purpose of this review is to describe the current condition of SCS and up-to-date technical advances.

The Use of Galvanostatic Pulse Transient Techniques for Assessing of Corrosion Rate of Reinforcing steel in Concrete (정전류 펄스법을 이용한 콘크리트 내 보강철근의 부식 연구)

  • So, Hyoung-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.785-793
    • /
    • 2007
  • An electrochemical transient response technique was used to study the corrosion of reinforcing steel bar in the concrete. Analysis of the transient electrochemical potential response in a corrosion interface to an applied current has enabled the separate components that make up the measured transient response to be isolated. These components display a range of resistances and capacitances, dependent on the corrosion conditions of the reinforcing steel, which may be attributed to the corrosion process, to effects within the concrete cover or to film effects on the surface of the concrete. In this technique, the corrosion rate was evaluated by summing all of the resistances in the separate components to obtain an aggregated corrosion resistance. However, it is possible that not all resistances identified are associated with the corrosion process. The results obtained show that the corrosion rates are significant dependent on the assignment of the separate components to either corrosion or to other processes. The assignment of resistive components associated with the corrosion rate can be clearly identified by taking a series of the transient measurement at different lateral distances from the corroding reinforcing steel. An inappropriate selection of measurement time however may result in an additional resistance, which is not associated with corrosion, being included or part of the resistance associated with corrosion being left out.

Studies on the Transport of Acetic Acid by Electrodialysis (전기투석에 의한 초산의 이동특성 연구)

  • 최동민;구윤모
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.360-366
    • /
    • 1996
  • Electrodialysis of acetic acid was studied to find out the trend of the transport of organic acids through ultrafiltration and ion exchange membranes. The net transport rate of acetic acid was determined from the electro-migration velocity relative to the electro-osmotic flow rate through the membrane. Electro-osmosis flows through ultrafiltration membranes were from the anodic side to the cathodic side in the presence of electric field. The surface of ultrafiltration membrane was measured by the electro-osmotic flow to be charged negatively. Different transport behaviors of acetic acid were found with the ultrafiltration membranes of different materials. In general, regenerated cellulose membranes (YM series) were more effective than polysulfone membranes (PM series) for the transport of acetic acid. The transport of acetic acid was affected by electric strength, distance between the electrodes, surface area of electrode, temperature, and pore size of membrane. The transport rate through the ion exchange membrane was 1.5 to 3 times of those through the ultrafiltration membranes at the constant current of 150 mA in the experimental ranges. The transport rate of acetic acid through the ion exchange membrane increased by 10% with a pulse electric field of 10 sec/hr.

  • PDF

New Drug Delivery System Based on a Laser-Induced Shockwave (레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발)

  • Han, Tae-Hee;Lee, Hyun-Hee;Gojani, Ardian B.;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Impingement of a high power laser pulse (above 1 GW/$cm^2$) on a metal foil causes its ablation, which is characterized by a rapid expulsion of matter and the initiation of a strong shock wave inside the solid metal. The shock propagates through the foil and reverberates on the rear side, causing its deformation and microparticle ejection, which were deposited on the foil prior to ablation. Based on this principle, we are developing a new drug delivery system - Biolistic gun. Current study is focused on the controllability, stability, efficiency of the system, and characterization of the penetration shapes in various conditions. We have tested the system by applying direct and confined ablation. Several different media combinations were used for confinement-BK7 glass, water, BK7 glass with water, and succulent jelly(ultrasono jelly, RHAPAPHRM). Biological tissue was replicated by a 3% gelatin solution. Present data shows that the confinement results in enhancement of penetration shape reached by 5 um cobalt microparticles. Based on the analysis of the experimental results we observe that the penetration shape of microparticles can be controlled by adjusting the thickness of confinement media.

Comparison of quality of 30:2 vs. 2:30 CPR in manikins (심폐소생술 방법 변화에 따른 quality 비교 - 30:2와 2:30 비교분석실험 -)

  • Uhm, Tai-Hwan;Yoou, Soon-Kyu;Choi, Hea-Kyung;Jung, Ji-Yeon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.3
    • /
    • pp.71-81
    • /
    • 2010
  • Purpose: To minimize an interruption in chest compression, reduce the hands-off time, the American Heart Association has recommended the ratio of chest compression to ventilation ratio to 30:2 from 2005 CPR guideline to 2010 CPR guideline. However, current studies have shown that the hands-off time was > 10 seconds with that method. For this reason, we devised new CPR method that a ventilation to chest compression ratio of 2:30 to reduce pt assessment time and skipped the assessment step of carotid artery pulse would be a more effective way to reduce the hands-off time & the time to set the CPR. According to the more detailed purpose are listed below. 1) We would like to confirm efficiency of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 to reduce the hands-off time & the time to set the CPR. 2) We would like to evaluate possibility of increasing for chest compression accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 3) We would like to evaluate possibility of increasing for ventilation accuracy of a ventilation to chest compression ratio of 2:30 than a chest compression to ventilation ratio of 30:2 Methods: According to 2005 American Heart Association Guidelines, 60 paramedic students(20 students X freshmen, sophomore, junior) performed 5 cycles of 3~ chest compressions : 2 ventilations after A, B, C evaluation with Laerdal Resusci R Anne SkillReporters. After 5 minutes rest, the 60 students performed 5 cycles of 2 ventilations : 30 chest compressions after A, B evaluation with the manikins between 13 and 17 September 2010. The short reports including speed & accuracy of chest compression, respiratory, CPR cycle were gained from the manikins. Hands-off times were measured by assistants. Results: Recently, the importance of high quality CPR was emphasized in order to perform the CPR faster and more accurate. To find out improving the conventional CPR method, we switch the procedure of the compression and the ventilation. By switching the procedure back and forth, we are able to compare the effectiveness of CPR between two type of CPR method which are 2:30 and 30:2 methods. 2:30 is that the breaths is delivered twice, first and perform 30 compressions while 30:2 perform 30 compressions first and give 2 breaths followed by the ABC method. Also, we verify the effectiveness of the hands off time, compression accuracy of the compression through the comparison of the two procedure as mentioned earlier. Consequently research verified that 2:30 is the efficient by providing faster set up delivering more accurate chest compression. Conclusion: 2:30 can minimize a time delay from cardiac standstill until starting the chest compression. In addition, hands-off time which is an interruption in chest compression can be shortened by 2:30 method, which result to effective oxygenation of coronary artery & maintenance of the bloodstream. Once again, performing the 2:30 method provide lessen hands off time and increase the accuracy of the chest compression.

  • PDF