A Novel Digital Lock-In Amplifier Based Harmonics Compensation Method for the Grid Connected Inverter Systems (계통연계 인버터를 위한 디지털 록인 앰프 기반의 새로운 고조파 보상법)

  • Amin, Saghir;Ashraf, Muhammad Noman;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.358-368
    • /
    • 2020
  • Grid-connected inverters (GCIs) based on renewable energy sources play an important role in enhancing the sustainability of a society. Harmonic standards, such as IEEE 519 and P1547, which require the total harmonic distortion (THD) of the output current to be less than 5%, should be satisfied when GCIs are connected to a grid. However, achieving a current THD of less than 5% is difficult for GCIs with an output filter under a distorted grid condition. In this study, a novel harmonic compensation method that uses a digital lock-in amplifier (DLA) is proposed to eliminate harmonics effectively at the output of GCIs. Accurate information regarding harmonics can be obtained due to the outstanding performance of DLA, and such information is used to eliminate harmonics with a simple proportional-integral controller in a feedforward manner. The validity of the proposed method is verified through experiments with a 5 kW single-phase GCI connected to a real grid.

An Improved Harmonic Compensation Method for a Single-Phase Grid Connected Inverter (단상 계통연계 인버터를 위한 개선된 고조파 보상법)

  • Khan, Reyyan Ahmad;Choi, Woojin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.215-227
    • /
    • 2019
  • Grid-connected inverters should satisfy a certain level of total harmonic distortion (THD) to meet harmonics standards, such as IEEE 519 and P1547. The output quality of an inverter is typically degraded due to grid voltage harmonics, dead time effects, and the device's turn-on/turn-off delay, which all contribute to increasing the THD value of the output. The use of a harmonic controller is essential to meet the required THD value for inverter output under a distorted grid condition. In this study, an improved feedforward harmonic compensation method is proposed to effectively eliminate low-order harmonics in the inverter current to the grid. In the proposed method, harmonic components are directly compensated through feedforward terms generated by the proportional resonant controller with the grid current in a stationary frame. The proposed method is simple to implement but powerful in eliminating harmonics from the output. The effectiveness of the proposed method is verified through simulation using PSIM software and experiments with a 5 kW single-phase grid-connected inverter.

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Single-phase Active Power Filter Based on Rotating Reference Frame Method for Harmonics Compensation

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.94-100
    • /
    • 2008
  • This paper presents a new control method of single-phase active power filter (APF) for the compensation of harmonic current components in nonlinear loads. To facilitate the possibility of complex calculation for harmonic current detection of the single phase, a single-phase system that has two phases was constructed by including an imaginary second-phase giving time delay to the load current. The imaginary phase, which lagged the load current T/4 (Here T is the fundamental cycle) is used in the conventional method. But in this proposed method, the new signal as the second phase is delayed by the filter. Because this control method is applied to a single-phase system, an instantaneous calculation was developed by using the rotating reference frames synchronized to source-frequency rather than by applying instantaneous reactive power theory that uses the conventional fixed reference frames. The control scheme of single-phase APF for the current source with R-L loads is applied to a laboratory prototype to verify the proposed control method.

Characteristics of the Current Density Induced Inside a Worker Near a Neutral Ground Reactor (중성점 접지 리액터 주변 작업자의 인체내부 유도전류밀도 특성)

  • Min, Suk-Won;Lee, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1856-1861
    • /
    • 2010
  • To reduce a high fault current, neutral ground reactors (NGR) were installed in the Korean substation. Current with several harmonic components flows in a NGR due to load unbalance in normal steady state and magnetic fields with several harmonic components are also generated around a NGR. As results of study, we found magnetic fields around a NGR in Korean substation included two harmonics, 180Hz and 540Hz. Magnetic fields of 180 Hz increased 3 times more current density inside a worker near a NGR than same magnitude magnetic fields of 60 Hz. We know a worker near a NGR may not meet ICNIRP guideline of 10(mA/$m^2$) due to several harmonic components.

A Study on the Islanding Detection for Grid Connected Photovoltaic System (계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구)

  • Lee Gi-Je;Kim Min;Lee Jin-Seop;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator (EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석)

  • 박재준;양태규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.

A New Injection Method of Harmonic Compensation Current by Active AC Power Filter (능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.9
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

A Study on Measurement and Analysis of Harmonics in Substation (변전소 고조파 측정 및 분석에 관한 연구)

  • Han Mu-Ho;Park Tae-Joon;Lee Seung-Hee;Lee Chi-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

Effects of Imperfect Sinusoidal Input Currents on the Performance of a Boost PFC Pre-Regulator

  • Cheung, Martin K.H.;Chow, Martin H.L.;Lai, Y.M.;Loo, K.H.
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.689-698
    • /
    • 2012
  • This paper investigates the effects of applying different input current waveshapes on the performance of a continuous-conduction-mode (CCM) power-factor-correction (PFC) boost pre-regulator. It is found that the output voltage ripple of the pre-regulator can be reduced if the input current is modified to include controlled amount of higher order harmonics. This finding allows us to balance the performance of output regulation and the harmonic current emission when coming to the design of the pre-regulator. An experimental PFC boost pre-regulator prototype is constructed to verify the analysis and show the benefit of the pre-regulator operating with input current containing higher order harmonics.