• Title/Summary/Keyword: Current harmonic

Search Result 1,338, Processing Time 0.035 seconds

Conductivity Imaging of a Canine Head using a 3T MREIT System with a Carbon-Hydrogel Electrode: Postmortem Experiment (3T MREIT 시스템을 이용한 실험견 사체의 두부 도전율 영상)

  • Jeong, Woo-Chul;Kim, Young-Tae;Minhas, Atul S.;Kim, Hyung-Joong;Lee, Tae-Hwi;Kang, Byeong-Teck;Park, Hee-Myung;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Magnetic Resonance Electrical Impedance Tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent MREIT studies demonstrated successful conductivity image reconstructions of postmortem and in vivo canine brain. However, the whole head imaging was not achieved due to technical issues related with electrodes and noise in measured magnetic flux density data. In this study, we used a new carbon-hydrogel electrode with a large contact area and injected 30 mA imaging current through a canine head. Using a 3T MREIT system, we performed a postmortem canine experiment and produced high-resolution conductivity images of the entire canine head. Collecting magnetic flux density data inside the head subject to multiple injection currents, we reconstructed cross-sectional conductivity images using the harmonic $B_z$ algorithm. The conductivity images of the canine head show a good contrast not only inside the brain region including white and gray matter but also outside the brain region including the skull, temporalis muscle, mandible, lingualis proprius muscle, and masseter muscle.

Oil Spill Behavior forecasting Model in South-eastern Coastal Area Of Korea (한국 동남해역에서의 유출유 확산예측모델)

  • Ryu Cheong Ro;Kim Jong Kyu;Seol Dong Guan;Kang Dong Uk
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.2
    • /
    • pp.52-59
    • /
    • 1998
  • Many concerns are placed on preservation of coastal environment from the spilled oil contaminant in the coastal area. And the use of computer simulation model to combat with oil spill has come to play mote important role in forecasting the oil spill trajectory so as to protect coastal area and minimize the damage from oil contaminants. The main concerns of this study is how the movements of spilled oil are affected by currents including tidal, oceanic, and wind-driven currents. Especially, in the present paper, the oil spill trajectory can be predicted by a real-time system that allows prediction of circulation and wind field. The harmonic methods are adopted to simulate the tidal currents as well as it can be possible to achieve the wind-field data and oceanic current data from the established database. System performance is illustrated by the simulation of oil spill in the south-eastern coastal area of Korea. Simulation results are compared with the observed one.

  • PDF

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

Ferroelectric and Antiferroelectric Behavior in Chiral Bent-shaped Molecules with an Asymmetric Central Naphthalene Core

  • Lee, Seng-Kue;Tokita, Masatoshi;Shimbo, Yoshio;Kang, Kyung-Tae;Takezoe, Hideo;Watanabe, Junji
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2241-2247
    • /
    • 2007
  • A new series of chiral bent-shaped liquid crystals with an asymmetric central core based on 1,6- dihydroxynaphthalene and chiral terminal chain prepared from (S)-(?)-2-methyl-1-butanol, 1,6-naphthalene bis[4-(4-alkoxyphenyliminomethyl)]benzoates [N(1,6)-n-O-PIMB(n-2)*-(n-4)O (n = 8-11)] were synthesized. Their mesomorphic properties and phase structures were investigated by means of electro-optical, polarization reversal current, and second harmonic generation measurements in order to confirm the relationship between the molecular structure and phase structure. All odd n (n = 9 and 11) compounds, N(1,6)-9-O-PIMB7*-5O and N(1,6)-11-O-PIMB9*-7O exhibit antiferroelectric phase, whereas even n (n = 8 and 10) compounds was flexible, N(1,6)-10-O-PIMB8*-6O exhibits the ferroelectric phase but N(1,6)-8-O-PIMB6*-4O exhibits the antiferroelectric phase. These results come from the decrease of the closed packing efficiency within a layer and the lack of uniform interlayer interaction between adjacent layers, which were caused by the asymmetrical naphthalene central core. Thus, we concluded that the structure of central core as well as the terminal chain plays an important role for the emergence of particular polar ordering in phase structures.

Numerical Analysis of Electromagnetic Radiation Characteristics by High Voltage and General Cables for Fuel Cell Electric Vehicle (FCEV) (수소 연료전지 차량용 고전압 케이블과 일반 케이블에 의한 차량 전자파 방사 특성 수치해석 연구)

  • Lee, Soon-Yong;Seo, Won-Bum;Lim, Ji-Seon;Choi, Jae-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) which is consisted of many motors in water pump, air blower, and hydrogen recycling pump as well as inverters for these motors is essential. Furthermore, there are also electric systems for entertainment, information, and vehicle control such as navigation, broadcasting, vehicle dynamic control systems, and so on. Since these systems are connected by high voltage or general cables, EMC (Electromagnetic compatibility) analysis for high voltage and general cable of FCEV is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields by high voltage and general cables for FCEVs is studied. From numerical analysis results, total time harmonic electromagnetic field strength from high voltage and general cables have difference of 13~16 dB due to ground effect by impedance matching. The EMI results of FECV at 10 m distance shows difference of 41 dB at 30 MHz and 54 dB at 230 MHz compared with only general cable routing.

The First Formant Characteristics in Vocalize of One Soprano (소프라노 1인의 모음곡 발성 시 제 1 포먼트의 변화양상)

  • Song, Yun-Kyung;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.10-14
    • /
    • 2005
  • Background and Objectives : Vowels are characterized on the basis of formant patterns. The first formant(F1) is determined by high-low placement of the tongue, and the second formant (F2) by front-back placement of the tongue. The fundamental frequency(F0) of a soprano often exceed the normal frequency of the first formant. And the vocal intensity is boosted when F0 is high and a harmonic coincides with a formant. This is called a formant tuning. Experienced singers thus learned how to tune their formants over a resonable range by lowering the tongue to maximize their vocal intensity. So, the current study aimed to identify the formant tuning in one experienced soprano by comparing the first formants of vowel [i] in three different voice production : speech, ascending scale, and vocalize. Materials and Method : All voices recordings of vowel [i] in speech, ascending scale (from F4 note to A4 note), and vocalize(:Ridente la calam") were made with digital audio tape-corder in a sound treated room. And the captured data were analyzed by the long term average(LTA) power spectrum using the FFT algorithm of the Computerized Speech Lab(CSL, Kay elementrics, Model, 4300B). Results : Although the first formant of vowel [i] in speech was 238Hz, those of ascending scale [i] were 377Hz, 405Hz, 453Hz respectively in F4(349z), G4(392Hz), A4(440Hz) note, and 722Hz, 820Hz, 918Hz respectively in F5 (698Hz), G5(784Hz), A5(880Hz) note. In vocalize, first formants of [i] were 380Hz, 398Hz, 453Hz respectively in F4, G4, A4 note, and 720Hz, 821Hz, 890Hz respectively in F5, G5, A5 note. Conclusion : These results showed that the first formant of ascending scale and vocalize sustained higher frequency than fundamental frequency in high pitch. This finding implicates that the formant tuning of vowel [i] in ascending scale was also noted in vocalize.

  • PDF

Tidal variations in the cable voltage across the Korea Strait

  • Lyu, Sang-Jin;Kim, Young-Gyu;Kim, Kuh;Book, Jeffrey W.;Choi, Byung-Ho
    • Journal of the korean society of oceanography
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • Cable voltage was measured simultaneously at Hamada, Japan and Pusan, Korea, using an inservice telephone cable from March to December 1990. The spectral and harmonic analyses of these data sets show that tidal signals are dominant, and that tidal constituents $M_2$ and $O_1$, which are not affected by solar geomagnetic variations, have almost the same amplitude and are of opposite phase to each other. comparing the voltage difference in 1990 with that measured using the now abandoned cable in 1998, there are dominant tidal signals at the same periods in both data sets. They have approximately the same amplitude and phase for $M_2andO_1$. The relationship between the observed voltage and the volume transport through the Korea Strait can be considered robust and stable over time. The conversion factor from voltage to transport is estimated to be $11.9{\times}10^6m^3S^{-1}volt^{-1}$ by comparing the amplitude of model-derived $M_2$ tidal transport with that of the voltage difference in 1998. This value changes to $8.6{\times}10^6m^3S^{-1}volt^{-1}$ when taking into consideration the horizontal electric current effect. This effect depends on the downstream length scale of the flow. To obtain a more reliable and stable conversion factor from voltage to transport, the voltage should be compared with observed sub-tidal transports, which may have long downstream length scales.

Analysis results of the Anti-islanding Function for PV-AF System (액티브 필터기능을 갖는 3상 태양광 발전시스템의 단독운전 방지기능의 분석)

  • Kim, Gyeong-Hun;Seo, Hyo-Ryong;Jang, Seong-Jae;Park, Sang-Soo;Park, Min-Won;Yu, In-Keun;Jeon, Jin-Hong;Kim, Seul-Ki;Jo, Chang-Hee;Ahn, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1085-1086
    • /
    • 2008
  • Shunt active filter can compensate harmonic current of utility results from non-linear loads such as rectifiers, cycloconverters and arc furnaces. It has the same structure as photovoltaic(PV) generation system. So, It was proposed the system that generates PV power and also has active filter function. It is called PV-AF(Photovoltaic and Active Filter) power generation system. Islanding can be occurred in an inverter based dispersed generation system, when the system disconnected from utility and loads are entirely supplied by PV system only. Islanding may result in interference to grid protection devices, equipment damage, and even personnel safety hazards. Therefore, islanding has to be detected and protected. The conventional anti-islanding methods have NDZ(None-Detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, a novel anti-islanding method for PV-AF system is proposed and analysed in detail.

  • PDF

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Ideal Housing in the Home Exposition Under the Japanese Colonial Rule (일제강점기 가정박람회에 나타난 이상주거)

  • Yang, Se-Hwa;Ryu, Hyun-Joo;Eun, Nan-Soon
    • Journal of the Korean Home Economics Association
    • /
    • v.47 no.1
    • /
    • pp.45-54
    • /
    • 2009
  • The purpose of the study is to examine the characteristics of the ideal housing for the modern family suggested by the Home Exposition (September, 1915) under the Japanese colonial rule in the macroscopic context of social change and the microscopic context of family. Through this research, we expect to have a partial understanding not only of changes in the outward appearance of traditional housing spaces during the civilization period and the early Japanese colonial rule when foreign cultures began to be introduced but also of families'residential lives and the patterns of change in people's consciousness of housing. Major conclusions from the current analysis are as follows. First, there were some changes in family paradigm induced through a home exhibition. Second, the most important factor for an ideal housing was that it must be the source of harmonic and healthy family life. Third, the importance of an appropriate space norm should be emphasized by providing the minimum size of each room. Fourth, the significance of the housing values of the economy, convenience, and hygiene should be emphasized for the ideal housing. Lastly, it was implied that for an ideal housing, the social and psychological aspects of housing must be satisfied along with the physical aspects. The limitation was that the model of ideal family housing presented in the Home Exposition cannot exclude the characteristics of the colonial perspectives in that it was followed by the model for the Japanese families.