• Title/Summary/Keyword: Current harmonic

Search Result 1,338, Processing Time 0.035 seconds

A single-phase high-power-factor rectifier using LC resonance in commercial frequenc (상용주파주의 LC공진을 이용한 단상고역률정류회로)

  • Kim, J.Y.;Lee, S.H.;Kim, Y.M.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.204-206
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances. capacitor input type rectifier circuits are generally used Consequently. various harmonics generated within the power system become a serious Problem. Various studies of this effect have been presented previously. However. most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over -load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method. It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency. Hence, the harmonic characteristics can be significantly improved. where the lower order harmonics. such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations.

  • PDF

Acoustic and Stroboscopic Characteristics in Clergies (목사들의 음성발성에 대한 음향분석학적 특징)

  • 진성민;박상욱;강현국;이경철;이용배;김보형
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 1998
  • Objectives : To compare the objective differences in voice quality and voice problems between clergies and normal male control group. Materials and Methods : The sustained vowel sound of 46 clergies and 40 normal persons were analyzed, using a videostroboscopy and acoustic analyzer. Together with these analyses, a questionnaire associated with current and past voice problems was handed over to the patients. Results : The most common symptom in subjective group was the voice fatigue. Stroboscopic findings in subjective group were as following 23 cases(50%) of pachydermia, 17 cases(37%) of phase difference, 12 cases(25%) of anterior-posterior contracture, 6 cases(13%) of vocal polyp and 3 cases(7%) of vocal nodule. The mean maximal phonation time in clergies was 17.8 seconds and in control group was 19 seconds. litter, pitch perturbation quotient and shimmer were significantly increased in subjective group than in control group(p<0.05), but there were no significant differences between two groups in fundamental frequency, vFo, amplitude perturbation quotient and noise to harmonic ratio. Conclusion : In the clergies using loud and forceful voice, vocal polyp and functional voice disorder findings were frequently noted in stroboscopic examination. litter and shimmer, reflecting the roughness of voice, were increased in acoustic analysis. Therefore, clergies, classified into untrained professional voice users, need professional career guidance and counseling.

  • PDF

SPECTROSCOPIC ADMITTIVITY IMAGING OF BIOLOGICAL TISSUES: CHALLENGES AND FUTURE DIRECTIONS

  • Zhang, Tingting;Bera, Tushar Kanti;Woo, Eung Je;Seo, Jin Keun
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.2
    • /
    • pp.77-105
    • /
    • 2014
  • Medical imaging techniques have evolved to expand our ability to visualize new contrast information of electrical, optical, and mechanical properties of tissues in the human body using noninvasive measurement methods. In particular, electrical tissue property imaging techniques have received considerable attention for the last few decades since electrical properties of biological tissues and organs change with their physiological functions and pathological states. We can express the electrical tissue properties as the frequency-dependent admittivity, which can be measured in a macroscopic scale by assessing the relation between the time-harmonic electric field and current density. The main issue is to reconstruct spectroscopic admittivity images from 10 Hz to 1 MHz, for example, with reasonably high spatial and temporal resolutions. It requires a solution of a nonlinear inverse problem involving Maxwell's equations. To solve the inverse problem with practical significance, we need deep knowledge on its mathematical formulation of underlying physical phenomena, implementation of image reconstruction algorithms, and practical limitations associated with the measurement sensitivity, specificity, noise, and data acquisition time. This paper discusses a number of issues in electrical tissue property imaging modalities and their future directions.

Superconducting magnet system of in-flight separator for a heavy ion accelerator planned in Korea

  • Kim, J.W.;Kim, D.G.;Jo, H.C.;Choi, Y.S.;Kim, S.H.;Sim, K.D.;Sohn, M.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.28-31
    • /
    • 2015
  • An in-flight fragment separator, which aims to produce and study rare isotopes, consists of superferric quadrupole triplets and $30^{\circ}$ dipole magnets to focus and bend the beams for achromatic focusing and momentum dispersion, respectively. The separator is divided into pre and main stages, and we plan to use superconducting magnets employing high-Tc superconductor (HTS) coils in the pre-separator area, where radiation heating is high. The HTS coils will be cooled by cold He gas in 20-50 K, and in the other area, superferric magnets using low-temperature superconductor (LTS) will be used at 4 K. A few LTS coils were wound and successfully tested in a LHe dewar, and the design of cryostat has been optimized. Development of the HTS coils is ongoing in collaboration with a group at KERI. An HTS coil of racetrack shape was wound and tested in a $LN_2$ bath and in a dewar with cryocooler. No degradation on critical current due to coil winding was found.

A New Performance Function-Based Control Strategy for Hybrid Series Active Power Filter in Three-Phase Four-Wire Systems (3상 4선식 하이브리드 형 직렬 능동전력필터에 대한 새로운 성능함수 제어 이론)

  • 신재화;김진선;김영석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.11
    • /
    • pp.563-571
    • /
    • 2003
  • In this paper, the control algorithm and control method for a combined system of shunt passive filter and series active filter in 3-phase 4-wire system are discussed. Moreover, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3th harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts may directly influence its compensation characteristics. Hence, the advantage of this control algorithm is direct extraction of compensation voltage reference and the required rating of the series active filter is much smaller than that of a conventional shunt active filter. Some experiments were executed and experimental results from a prototype active power filter confirm the suitability of the proposed approach.

An Estimation Technology of Temperature Rise in GIS Bus Bar using Three-Dimensional Coupled-Field Multiphysics (연성해석을 이용한 초고압 모선부 온도 상승 예측 기술)

  • Yoon, Jeong-Hoon;Ahn, Heui-Sub;Choi, Jong-Ung;Oh, Il-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.675-676
    • /
    • 2006
  • This paper shows the temperature rise of the high voltage GIS bus bar. The temperature rise in GIS bus bar is due to Joule's losses in the conductor and the induced eddy current in the tank. The power losses of a bus bar calculated from the magnetic field analysis are used as the input data for the thermal analysis to predict the temperature. The required analysis is a couple-field Multiphysics that accounts for the interactions between three-dimensional AC harmonic magnetic and fluid fields. The heat transfer calculation using the fluid analysis is done by considering the natural convection and the radiation from the tank to the atmosphere. Consequently, because temperature distributions by couple-field Multiphysics (coupled magnetic-fluid) have good agreement with results of temperature rise test, the proposed couple-field Multiphysics technique is likely to be used in a conduction design of the single-pole and three pole-encapsulated bus bar in CIS..

  • PDF

Free vibration analysis of non-prismatic beams under variable axial forces

  • Saffari, H.;Mohammadnejad, M.;Bagheripour, M.H.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.5
    • /
    • pp.561-582
    • /
    • 2012
  • Despite popularity of FEM in analysis of static and dynamic structural problems and the routine applicability of FE softwares, analytical methods based on simple mathematical relations is still largely sought by many researchers and practicing engineers around the world. Development of such analytical methods for analysis of free vibration of non-prismatic beams is also of primary concern. In this paper a new and simple method is proposed for determination of vibration frequencies of non-prismatic beams under variable axial forces. The governing differential equation is first obtained and, according to a harmonic vibration, is converted into a single variable equation in terms of location. Through repetitive integrations, integral equation for the weak form of governing equation is derived. The integration constants are determined using the boundary conditions applied to the problem. The mode shape functions are approximated by a power series. Substitution of the power series into the integral equation transforms it into a system of linear algebraic equations. Natural frequencies are determined using a non-trivial solution for system of equations. Presented method is formulated for beams having various end conditions and is extended for determination of the buckling load of non-prismatic beams. The efficiency and convergence rate of the current approach are investigated through comparison of the numerical results obtained to those obtained using available finite element software.

An active damping method of a grid-connected PWM Inverter using an instantaneous power theory (순시전력이론을 통한 계통연계 PWM 인버터 시스템의 능동댐핑 기법)

  • Jung, Hea-Gwang;Lee, Kyo-Beum;Kang, Sin-Il;Lee, Hyen-Young;Kwon, Oh-Joeng;Song, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.85-87
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations.

  • PDF

A Novel Modulation Scheme and a DC-Link Voltage Balancing Control Strategy for T-Type H-Bridge Cascaded Multilevel Converters

  • Wang, Yue;Hu, Yaowei;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2099-2108
    • /
    • 2016
  • The cascaded multilevel converter is widely adopted to medium/high voltage and high power electronic applications due to the small harmonic components of the output voltage and the facilitation of modularity. In this paper, the operation principle of a T-type H-bridge topology is investigated in detail, and a carrier phase shifted pulse width modulation (CPS-PWM) based control method is proposed for this topology. Taking a virtual five-level waveform achieved by a unipolar double frequency CPS-PWM as the output object, PWM signals of the T-type H-bridge can be obtained by reverse derivation according to its switching modes. In addition, a control method for the T-type H-bridge based cascaded multilevel converter is introduced. Then a single-phase T-type H-bridge cascaded multilevel static var generator (SVG) prototype is built, and a repetitive controller based compound current control strategy is designed with the DC-link voltage balancing control scheme analyzed. Finally, simulation and experimental results validate the correctness and feasibility of the proposed modulation method and control strategy for T-type H-bridge based cascaded multilevel converters.

Design and Implementation of Miniature VCO using LTCC Technique (LTCC 기법을 이용한 초소형 VCO 설계 및 구현)

  • 김태현;권원현;이영훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1176-1183
    • /
    • 2003
  • In this paper, miniature voltage-controlled oscillator(VCO) for 1.6 ㎓ PCS band is designed and implemented using the LTCC technique. Circuit level design using commercial components is performed, and passive L, C elements embedded in LTCC substrate is optimized by simulation tools. Embedded passive components are modeled into equivalent circuits and their circuit parameters are extracted for circuit simulation. Utilizing the designed embedded passive elements and 21 layers LTCC substrate, VCO with 4.0${\times}$4.0${\times}$1.6 ㎣ dimensions is designed and fabricated. Developed VCO operates in 2.7 V with 8.5 ㎃ current consumption. The phase noise performance of VCO is below -112.61 ㏈c/㎐ at 100 ㎑ offset and harmonic suppression characteristics is measured above -30 ㏈.