• Title/Summary/Keyword: Current comparison

Search Result 3,215, Processing Time 0.031 seconds

Comparison of Current Control Method for Single-phase PFC converter with 1-switch Voltage Doubler Strategy (단일 스위치 배전압 방식의 단상 PFC 컨버터의 전류 제어기법 비교)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Guee-Soo;Lim, Seung-Beom;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • This paper describes the performance comparison results for current controller of a single-phase PFC converter with 1-switch voltage doubler strategy for single-phase double-conversion UPS(Uninterruptible Power Supply). A single-phase PFC converter with 1-switch voltage doubler strategy needs a diode bridge and one bidirectional active switch. Thus it is possible to reduce the material cost. However, the study results of current controller design and comparison of current control method has not been known after the converter circuit was proposed. For the performance comparison of current control, single-phase 3 kVA double-conversion UPS was tested. The performance of PI and PR current controller is experimentally confirmed with followings - input current reference tracking, input power factor correction and input current THD suppression.

Interlaboratory Comparison of Critical Current Measurements on Ag-sheathed Bi-2223 tapes (Bi-2223선재의 임계전류 측정기술 비교)

  • Lee, Kyu-Won;Han, Gi-Youl
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.99-103
    • /
    • 2001
  • We have conducted two runs of interlaboratory comparison on Ag-sheathed Bi-2223 tapes to evaluate the level of measurement techniques for the critical current measurement. Two classes of specimens were prepared for parallel and serial routings and sent to four participating laboratories. The critical currents of specimens were measured at 77 K in zero magnetic field. In the first comparison, we used twenty different Bi-2223 tapes as specimens for comparison and participating laboratories measured the specimens using their own instruments and procedures. As a result, the scattering of data on the first comparison showed -3.0% to +l2.2% for the parallel routing and -0.7% to +l5.1% for the serial routing. Major sources of these variations were attributed to different measurement techniques. Thus, the second comparison of measurement was done on the same specimens under specified measurement conditions, particularly in terms of cooling procedure and sweep rate of the test current. The variations for the second comparison were decreased -3.1% to +3.2% far the parallel routing and -1.8% to +7.7% fur the serial routing.

  • PDF

Comparison between analytic and numerical approaches to calculate screening current induced field in HTS magnet

  • Bang, Jeseok;Kim, Seokho;Kim, Jaemin;An, Soobin;Im, Chaemin;Hahn, Seungyong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.45-49
    • /
    • 2019
  • This paper reports comparison between analytic and numerical simulation approaches for calculation of screening current and screening current induced field in a high temperature superconductor magnet. Bean slab model is adopted to calculate screening current and SCF analytically, while the finite element method numerically. A case study of screening current and SCF calculation are conducted with a magnet, a 7 T 68 mm cold-bore multi-width no-insulation GdBCO magnet built and tested by Massachusetts Institute of Technology Francis Bitter Magnet Laboratory. In this study, we assume the magnet is dunked in liquid nitrogen at 77 K. Furthermore, the simulation results are compared in terms of computation time and accuracy. Finally, discussion on the different methods together with the comparison between the calculations and experiment is provided.

A calibration of high current measuring sensors by comparison tests (비교 시험에 따른 대전류 측정 센서 교정 결과 분석)

  • Han, Jong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

Comparison Analysis of Resonant Controllers for Current Regulation of Selective Active Power Filter with Mixed Current Reference

  • Yi, Hao;Zhuo, Fang;Li, Yu;Zhang, Yanjun;Zhan, Wenda
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.861-876
    • /
    • 2013
  • Instead of extracting every selected harmonic component, the current reference of selective active power filter (APF) can be also obtained by filtering out the fundamental component from distorted load current for computation efficiency. This type of mixed current reference contains kinds of harmonic components and easily involves noises. In this condition, selective harmonic compensation must be realized by the current controller. With regard that selectivity is the most significant feature of controller, this paper presents specific comparison analysis between two types of resonant controllers: proportional-resonant (PR) controller and vector-resonant (VR) controller. The comparison analysis covers the relations, performances, and stability of both controllers. Analysis results conclude that the poorer selectivity of the PR controller could be relatively improved, but limitations from system stability make the improvement hardly realized. By contrast, the VR controller exhibits excellent selectivity and is more suitable for selective APF with mixed current reference. Experimental results from laboratory prototype validate the reasonability of analysis. And the features of each resonant controller are concluded.

Comparison of Efficiency for Voltage Source and Current Source Based Converter in 5MW PMSG Wind Turbine Systems

  • Kang, Tahyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.357-358
    • /
    • 2015
  • This paper provides a comparison of power converter loss and thermal description for voltage source and current source type 5MW-class medium voltage topologies of wind turbines. Neutral-point clamped three-level converter is adopted for voltage source type topology while two-level converter is employed for current source type topology considering the popularity in the industry. In order to match the required voltage level of 4160V with the same switching device of IGCT as in voltage source converter, two active switches are connected in series for the case of current source converter. The loss analysis is confirmed through PLECS simulations. In addition, the loss factors due to di/dt and dv/dt snubber and ac input filter are presented. The comparison result shows that VSC-based wind turbine system has a higher efficiency than that of CSC under the rated operating conditions.

  • PDF

A current sense amplifier for low-voltage and high-speed SRAM (저전압 SRAM 의 고속동작을 위한 전류감지 증폭기)

  • Park, Hyun-Wook;Shim, Sang-Won;Chung, Yeon-Bae
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.727-730
    • /
    • 2005
  • In this paper, we propose a new current sense amplifier for low-voltage, high-speed SRAM. As a supply voltage is reduced, a sensing delay is increased owing to reduced cell read current. It causes a low-speed operation in SRAM. To overcome this problem, we present a new current sense amplifier which consists of the current-mirror type circuit with feedback structure. For demonstration, a 0.8-V, 256-Kb SRAM incorporating the proposed current sense amplifier has been designed with $0.18-{\mu}m$ CMOS technology. The simulation results show 15.6ns of the sensing delay reduction in comparison with a previous current sense amplifier and 11.5ns of the sensing delay reduction in comparison with a voltage sense amplifier.

  • PDF

A Fuzzy Current Controller using General Purposed Fuzzy Control Software Tool (범용 퍼지 지원 도구를 이용한 퍼지 전류제어기)

  • Min, Seong-Sik;Lee, Kyu-Chan;Song, Jhong-Whan;Cho, Kyu-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.341-344
    • /
    • 1991
  • Current controlled pulse width modulation(PWM) for voltage source inverter(VSI) is one of the control method which controls the current directly so that we can perform vector control because it reduces the orders of differential equations of the induction machine. This paper propose a Fuzzy current controlled PWM which properly minimize a current ripple using Fuzzy theory in a constant switching frequency. This technique is applied to an electrical drive system with an induction machine(IM) by simulation. By comparison with the known classical method such as ramp comparison, hysteresis band method, our contribution shows the better performances.

  • PDF

Analysis of Surface Current Measurement Based on X-band Radar Image (X-밴드 레이더 이미지 기반 표층해류 계측 분석)

  • Na-Yun Kang;Yu-Kyung Lee;Young-Jun Yang
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.323-324
    • /
    • 2022
  • This paper explains the comparison results of surface current measurement using X-band Radar image through analysis. Measurements were carried out from February 2022 using the X-band Radar for marin ships installed at Sokcho Beach. Based on the Korea Hydrographic and Oceanographic Agency ocean observation buoys, the accuracy of surface current(current speed) measurement was verified through comparison and analysis of measurement data.

  • PDF