• 제목/요약/키워드: Current Control Structure

검색결과 863건 처리시간 0.024초

A Novel Control Strategy for Input-Parallel-Output-Series Inverter System

  • Song, Chun-Wei;Zhao, Rong-Xiang;Lin, Wang-Qing;Zeng, Zheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.85-90
    • /
    • 2012
  • This paper presents a topology structure and control method for an input-parallel-output-series(IPOS) inverter system which is suitable for high input current, high output voltage, and high power applications. In order to ensure the normal operation of the IPOS inverter system, the control method should achieve input current sharing(ICS) and output voltage sharing(OVS) among constituent modules. Through the analysis in this paper, ICS is automatically achieved as long as OVS is controlled. The IPOS inverter system is controlled by a three-loop control system which is composed of an outer common-output voltage loop, inner current loops and voltage sharing loops. Simulation results show that this control strategy can achieve low total harmonic distortion(THD) in the system output voltage, fast dynamic response, and good output voltage sharing performance.

최적규모의 변전소 집중원방감시제어(SCADA) 시스템 구성 (The configuration of optimal structure for substation SCADA system)

  • 이용해;남태현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.678-682
    • /
    • 1988
  • Current substation SCADA system has only one control center where two or three operaters monitor and control more than 40 substations spreaded far and wide. The scope of this system is too wide to cope with the concurrent multiple accidents in electric network by the typhoon and large mow. This paper describes the method to organize the optimal structure of substation SCADA system using remote console and small scale control center.

  • PDF

N.P.C 구조에 의한 히스테리시스 전류제어기의 전압파형 개선 (A Hysteresis Current Controller with Improved Voltage Waveform using N.P.C Structure)

  • 김윤호;이병송
    • 전력전자학회논문지
    • /
    • 제2권3호
    • /
    • pp.51-57
    • /
    • 1997
  • 본 논문은 기존의 히스테리시스 전류 제어기에 N.P.C(Neutral-Point-Clamped) 인버터의 구조를 교류 전동기 시스템의 적용하므로서 전동기 시스템의 토오크 특성의 개선 및 손실의 원인이 되는 고조파 성분을 감소시키기 위한 기법을 제안하였다. 제안된 스위칭 기법은 기존의 히스테리시스 전류제어기를 적용하는 인버터와 비교하여 50%의 스위칭 주파수의 저감 효과를 기할 수 있다. 본 논문에서는 제안된 스위칭 기법의 특성을 기존의 스위칭 기법과 비교하여 시뮬레이션을 시행함으로서 제안된 스위칭 기법의 우수성을 입증하였다.

  • PDF

Analysis of Principle and Performance of a New 4DOF Hybrid Magnetic Bearing

  • Bai, Guochang;Sun, Jinji;Han, Weitao;Ren, Hongliang
    • Journal of Magnetics
    • /
    • 제21권3호
    • /
    • pp.379-386
    • /
    • 2016
  • To satisfy the requirement of magnetically suspended control moment gyroscope (MSCMG) that magnetic bearing can provide torque, a novel 4DOF hybrid magnetic bearing (HMB) with integrated structure was designed. Mathematical models of forces and torques are established by using equivalent magnetic circuit method. The current stiffness, displacement stiffness, tilting current stiffness and angular stiffness of the 4DOF hybrid magnetic bearing are derived by the mathematical models. Equivalent magnetic circuit method and finite element method (FEM) simulation results indicate that the force has a good linear relationship with both displacement and current, and the torque has a good linear relationship with angular displacement and current. The novel 4DOF HMB is capable of achieving control in both two radial translational degrees of freedom (DOF) and also two radial rotational DOFs. The 4DOF HMB is well adapted to MSCMG system, exhibiting advantages in the controllable DOF, light weight and easy to control.

A GHz-Level RSFQ Clock Distribution Technique with Bias Current Control in JTLs

  • Cho W.;Lim J.H.;Moon G.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.17-19
    • /
    • 2006
  • A novel clock distribution technique for pipelined-RSFQ logics using variable Bias Currents of JTLs as delay-medium is newly proposed. RSFQ logics consist of several logic gates or blocks connected in a pipeline structure. And each block has variable delay difference. In the structure, this clock distribution method generates a set of clock signals for each logic blocks with suitable corresponding delays. These delays, in the order of few to tens of pS, can be adjusted through controlling bias current of JTL of delay medium. While delays with resistor value and JJ size are fixed at fabrication stage, delay through bias current can be controlled externally, and thus, is heavily investigated for its range as well as correct operation within current margin. Possible ways of a standard delay library with modular structure are sought for further modularizing Pipelined-RSFQ applications. Simulations and verifications are done through WRSpice with Hypres 3-um process parameters.

A Compensator for Lateral Current Reduction Applied to Autonomously Controlled UPSs Connected in Parallel

  • Sato Kazuhide Kazuhide;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.312-318
    • /
    • 2005
  • This paper presents a compensator for reduction of the reactive lateral current in multiple autonomously controlled uninterruptible power supplies (UPS) connected in parallel. This compensator acts directly on the control equation for voltage amplitude and it provides an improved current distribution especially in the case of parallel connection of UPSs with different output power ratings. Observations show that the original control equation for output voltage amplitude is efficient for voltage regulation but it causes great variation of voltage levels. A compensator with the same structure is added to counterbalance the variation caused by the original control equation. Simulations show promising results with the employment of the proposed compensator. Our simulations are confirmed by experimental results using three UPSs with different output ratings and voltage limiters ($1\%$) connected in parallel under various conditions.

전류형 MPPT를 이용한 3 kW 태양광 인버터 시스템 제어기 설계 및 구현 (Design and implementation of 3 kW Photovoltaic Power Conditioning System using a Current based Maximum Power Point Tracking)

  • 차한주;이상회;김재언
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1796-1801
    • /
    • 2008
  • In this paper, a new current based maximum power point tracking (CMPPT) method is proposed for a single phase photovoltaic power conditioning system and the current based MPPT modifies incremental conductance method. The current based MPPT method makes the entire control structure of the power conditioning system simple and uses an inherent current source characteristic of solar cell array. In addition, digital phase locked loop using an all pass filter is introduced to detect phase of grid voltage as well as peak voltage. Controllers about dc/dc boost converter, dc-link voltage, dc/ac inverter is designed for a coordinated operation. Furthermore, PI current control using a pseudo synchronous d-q transformation is employed for grid current control with unity power factor. 3kW prototype photovoltaic power conditioning system is built and its experimental results are given to verify the effectiveness of the proposed control schemes.

A novel grey TMD control for structures subjected to earthquakes

  • Z.Y., Chen;Ruei-Yuan, Wang;Yahui, Meng;Timothy, Chen
    • Earthquakes and Structures
    • /
    • 제24권1호
    • /
    • pp.1-9
    • /
    • 2023
  • A model for calculating structure interacted mechanics is proposed. A structural interaction model and controller design based on tuned mass damping (TMD) was developed to control the induced vibration. A key point is to introduce a new analytical model to evaluate the properties of the TMD that recognizes the motion-dependent nonlinear response observed in the simulations. Aiming at the problem of increased current harmonics and low efficiency of permanent magnet synchronous motors for electric vehicles due to dead time effect, a dead time compensation method based on neural network filter and current polarity detection is proposed. Firstly, the DC components and the higher harmonic components of the motor currents are obtained by virtue of what the neural network filters and the extracted harmonic currents are adjusted to the required compensation voltages by virtue of what the neural network filters. Then, the extracted DC components are used for current polarity dead time compensation control to avert the false compensation when currents approach zero. The neural network filter method extracts the required compensation voltages from the speed component and the current polarity detection compensation method obtains the required compensation voltages by discriminating the current polarity. The combination of the two methods can more precisely compensate the dead time effect of the control system to improve the control performance. Furthermore, based on the relaxed method, the intelligent approach of stability criterion can be regulated appropriately and the artificial TMD was found to be effective in reducing cross-wind vibrations.

An Efficient and High-gain Inverter Based on The 3S Inverter Employs Model Predictive Control for PV Applications

  • Abdel-Rahim, Omar;Funato, Hirohito;Junnosuke, Haruna
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1484-1494
    • /
    • 2017
  • We present a two-stage inverter with high step-up conversion ratio engaging modified finite-set Model Predictive Control (MPC) for utility-integrated photovoltaic (PV) applications. The anticipated arrangement is fit for low power PV uses, the calculated efficiency at 150 W input power and 19 times boosting ratio was around 94%. The suggested high-gain dc-dc converter based on Cockcroft-Walton multiplier constitutes the first-stage of the offered structure, due to its high step-up ability. It can boost the input voltage up to 20 times. The 3S current-source inverter constitutes the second-stage. The 3S current-source inverter hires three semiconductor switches, in which one is functioning at high-frequency and the others are operating at fundamental-frequency. The high-switching pulses are varied in the procedure of unidirectional sine-wave to engender a current coordinated with the utility-voltage. The unidirectional current is shaped into alternating current by the synchronized push-pull configuration. The MPC process are intended to control the scheme and achieve the subsequent tasks, take out the Maximum Power (MP) from the PV, step-up the PV voltage, and introduces low current with low Total Harmonic Distortion (THD) and with unity power factor with the grid voltage.

A ROBUST VECTOR CONTROL FOR PARAMETER VARIATIONS OF INDUCTION MOTOR

  • Park, Jee-ho;Cho, Yong-Kil;Woo, Jung-In;Ahn, In-Mo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.330-335
    • /
    • 1998
  • In this paper the robust vector control method of induction motor for the purpose of improving the system performance deterioration caused by parameter variations is proposed. The estimations of the stator current and the rotor flux are obtained by the full order state observer with corrective prediction error feedback. and the adaptive scheme is constructed to estimate the rotor speed with the error signal between real and estimation value of the stator current. Adaptive sliding observer based on the variable structure control is applied to parameter identification. Consequently predictive current control and speed sensorless vector control can be obtained simultaneously regardless of the parameter variations.

  • PDF