• Title/Summary/Keyword: Current Control Loop

Search Result 641, Processing Time 0.039 seconds

A Study of the Dynamic Performance Improvement of a Linear Compressor Stroke Controller with a Current Control Loop (전류제어 루프를 갖는 선형 압축기 스트로크 제어기의 동적 성능 향상에 관한 연구)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.274-282
    • /
    • 2013
  • In this paper, a linear motor stroke controller using a phase lag filter and a single phase PWM inverter with a current controller has been implemented. In order to control the cooling capability of a refrigerator or an air conditioner in which linear compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. Generally, the frequency is fixed, for example, as 60Hz and the stroke is adjusted. The dynamic performance of linear compressors depends on how accurately the stroke or the piston position is controlled by the current applied. A linear motor piston position controller with a current control loop is proposed and verified via some simulation studies.

Performance Comparison of Different Solar Array Simulator Control by Ellipse Approximation (태양광패널 모사장치의 제어방식에 따른 소신호 특성 비교 분석)

  • Wellawatta, Thusitha;Seo, Young-Tae;Choi, Sung-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.16-24
    • /
    • 2021
  • Solar array simulator (SAS) is essential equipment in testing and evaluating the power processing performance of a power conditioning system. However, the nonlinearity in the current(I)-voltage(V) characteristic makes the control loop design of SAS a challenging task. Conventionally, only the inner loop is usually considered in the control design approach. However, this study proves that the reference generation loop also interacts with the inner loop and plays a key role in the overall performance of the SAS. In this paper, the performance of voltage-mode control and impedance control, which are two of the most popular architectures for the SAS system, are reviewed and compared by multi-loop analysis.

A Novel Voltrol Method of Three-Phase PWM Inverter for UPS Application (UPS 응용을 위한 3상 PWM 인버터의 새로운 전압 제어 방법)

  • 이영조;박남주;임철우;정세교
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.260-265
    • /
    • 1999
  • This paper describes a novel control method of a three-phase PWM inverter for uninterruptible power supply(UPS) applications. To obtain the fast dynamics and excellent harmonic characteristics, a new state feedback control technique is proposed. The proposed control consists of the inner-loop current and outer-loop voltage controllers with a load current estimator to reduce the effects of the load variations and nonlinearity. In order to verify the effectiveness of the proposed control, the simulation is carried out for various load condition.

  • PDF

Analysis of Stability and Dynamic Behaviour of Ultra Lift Luo Converter

  • Raji, J.;Kamaraj, V.
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1970-1979
    • /
    • 2017
  • Ultra Lift Luo Converter (ULC) gained considerable research interest in recent years. The stability analysis of voltage mode and peak current mode controlled ULC in continuous conduction mode is analyzed in this paper. The Eigen value theory is used for the stability analysis of voltage mode controlled ULC. Then to characterize the dynamics of inner current loop, the expressions of closed loop transfer function and loop gain are determined. An algorithm has been developed to analyze the stability of the peak current mode controlled ULC. The theoretical results are correlated with the simulation results obtained using PSIM 9.1(SMARTCTRL 1.0) software. Finally it is proposed to fabricate a prototype and validate the performance by suitable experimental setup.

Implementation of Position Control of PMSM with FPGA

  • Reaugepattanawiwat, Chalermpol;Eawsakul, Nitipat;Watjanatepin, Napat;Pinprathomrat, Prasert;Desyoo, Phayung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1254-1258
    • /
    • 2004
  • This paper presents of position control of Permanent Magnet Synchronous Motor (PMSM) the implementation with Field Programmable Gate Array (FPGA) is proposed. Cascade control with inner loop as a current control and an outer loop as a position control is chosen for simplicity and fast response. FPGA is a single chip (single processing unit), which will perform the following tasks: receive and convert control signal, create a reference current signal, control current and create switch signal and act as position controller in a addition of zero form. The 10 kHz sampling frequency and 25 bit of floating point data are defined in this implementation.The experimental results show that the performance of FPGA based position control is comparable with the hardware based position control, with the advantage of control algorithm flexibility

  • PDF

Development of a full-scale magnetorheological damper model for open-loop cable vibration control

  • Zhang, Ru;Ni, Yi-Qing;Duan, Yuanfeng;Ko, Jan-Ming
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.553-564
    • /
    • 2019
  • Modeling of magnetorheological (MR) dampers for cable vibration control to facilitate the design of even more effective and economical systems is still a challenging task. In this study, a parameter-adaptive three-element model is first established for a full-scale MR damper based on laboratory tests. The parameters of the model are represented by a set of empirical formulae in terms of displacement amplitude, voltage input, and excitation frequency. The model is then incorporated into the governing equation of cable-damper system for investigation of open-loop vibration control of stay cables in a cable-stayed bridge. The concept of optimal voltage/current input achieving the maximum damping for the system is put forward and verified. Multi-mode suboptimal and Single-mode optimal open-loop control method is then developed. Important conclusions are drawn on application issues and unique characteristics of open-loop cable vibration control using MR dampers.

Study on MPPT controller using limit cycle (리미트 사이클을 이용한 MPPT 제어기에 대한 연구)

  • Kang Taekyung;Koh Kanghoon;Kwon Soonkurl;Suh Kiyoung;Nakaoka Mutsuo;Lee Hyunwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.160-163
    • /
    • 2005
  • This paper proposes a simple MPPT control scheme of a Current-Control-Loop Error system Based that can be obtains a lot of advantage to compare with another digital control method, P&O and IncCond algorithm, that is applied mostly a PV system. An existent method is needed an expensive processor such as DSP that calculated to change the measure power of a using current and voltage sensor at the once. Therefore, it is applied a small home power generation system that required many expenses. But, a proposed method is easy to solve the cost reduction and power unbalance problems that it is used by control scheme to limit error of a current control of common sensor. This proposed algorithm had verified through a simulation and an experiment on battery charger using PIC that is the microprocessor of a low price.

  • PDF

Control of Input Series Output Parallel Connected DC-DC Converters

  • Natarajan, Sirukarumbur Pandurangan;Anandhi, Thangavel Saroja
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.265-270
    • /
    • 2007
  • Equal rating DC-DC converter modules can be connected in series at the input for circuits requiring higher input voltages and in parallel at the output for circuits requiring higher output currents. Since the converter modules may not be practically identical, closed loop control has to ensure that each module equally shares the total input voltage and the load current. A control scheme consisting of a common output voltage loop, individual inner current loops and individual input voltage loops have been designed in this work to achieve input voltage and load current sharing as well as load voltage regulation under supply and load disturbances. The output voltage loop provides the basic reference for the inner current loops, which are also modified by the respective input voltage loops. The average of the converter input voltages, which is dynamically varying, is chosen as the reference for input voltage loops. This choice of reference eliminates interaction among different control loops. Type II compensators and Fuzzy Logic Controllers (FLCs) are designed and compared through MATLAB based simulation and FLC is found to be satisfactory. Hence TMS320F2407A DSP based FLC is implemented and the results are presented which prove the superiority of the FLC developed for this research.

Analysis of the Charge Controlled Inductor Current Sensing Peak-Power-Tracking Solar Array Regulator

  • Lee, K.S.;Cho, Y.J.;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.982-986
    • /
    • 1998
  • The peak-power-tracking solar array regulator sensing the inductor current is proposed. Since it uses the inductor current as the solar array output power information, the PPT control scheme can be greatly simplified. The charge controlled two-loop scheme is presented to improve the dynamics due to the inductor current sensing. The comparison between the single-voltage loop controlled system and the two-loop controlled system employing the charge control is presented. This paper also contains the simulation results of that comparison.

  • PDF

A novel design method for the velocity controller of DC servo motor (새로운 DC 서어보 모우터 속도제어기 설계에 관한 연구)

  • 장태규;변증남
    • 전기의세계
    • /
    • v.30 no.8
    • /
    • pp.501-508
    • /
    • 1981
  • A novel and simple method of designing the current feedback loop for the velocity controller of an armature controlled dc servo motor is presented. Instead of constructing the usual tight current feedback loop, a loose current feedback loop is suggested in this paper. More specifically, the armature current is not limited to a fixed constant value, but instead the upper bound value is allowed to be variable along with the present motor speed. The control system designed in this manner shows that the motor under control is robust to a wide range of loading conditions and yields a more rapid transient characteristics which is verified experimentally by applying the method in the design of the controller for an Industrial robot.

  • PDF