• Title/Summary/Keyword: Culvert

Search Result 179, Processing Time 0.034 seconds

Development of Parametric BIM Libraries for Civil Structures using National 2D Standard Drawings (국가 표준도를 이용한 토목 구조물 BIM 파라메트릭 라이브러리 구축에 관한 연구)

  • Kim, Cheong-Woon;Koo, Bonsang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.4
    • /
    • pp.128-138
    • /
    • 2014
  • Development of infrastructure component libraries is a critical requirement for the accelerated adoption of BIM in the civil engineering sector. Libraries reduce the time for BIM model creation, allows accurate quantity take offs, and shared use of standard models in a project. However, such libraries are currently in very short supply in the domestic infrastructure domain. This research introduces library components for retaining walls and box culverts generated from 2D standard drawings made publicly available by MOLIT. Commercial BIM software was used to create the concrete geometry and rebar, and dimensional/volumetric parameters were defined to maximize the reuse and generality of the libraries. Use of the these libraries in a project context demonstrates that they allow accurate and quick quantity take offs, and easier management of geometric information through the use of a single library as to numerous 2D drawings. It also demonstrates the easy modification of the geometries of the components if and when they need to changed. However, the application also showed that some of the rebar components (stirrups and length wise rebars) do not get properly updated when concrete geometries are changed, demonstrating the limits of current software applications. The research provides evidence of the many advantages of using BIM libraries in the civil engineering, thus providing the incentive for further development of standard libraries and promoting the use of BIM in infrastructure projects.

A design guide to minimize frost heave in unbound pavement layers over box culverts (저토피부 암거상부 포장의 도상피해 예방을 위한 단명설계)

  • Seo, Young-Guk
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.111-121
    • /
    • 2007
  • During the whole month of December in 2005, Korea experienced both heavy snowfall and freezing temperature in southeast regions, which had caused frost related damages to many pavements laid on top of box culverts. In-situ observation revealed that the formation of ice lenses in subgrade and subsequent unbound layers led to upward heaving and transverse cracks in concrete and asphalt pavements. This has affected the long-term performance of pavements, as well as has threatened drivers' safety for a while. Recently, Korea Expressway Corporation has proposed a design guide to better protect newly constructed unbound pavement layers over culverts from frost heave. A trench drainage system has been selected to effectively draw off water and to alleviate pore-water pressure in soils during the coldest season. This paper presents experimental and analytical backgrounds behind this new design guide. Soil specimens retrieved from the sites are tested to quantify clay content and to estimate the permeability of subgrade. A 2-D ground seepage analysis has been conducted to better understand the changes in pore water pressures as a function of grain size. Finally, an optimum size of trench drainage is determined based on numerical analysis and workability in the field.

  • PDF

An Experimental Study on Flow Characteristics Around Culvert According to Blocked Area (차단면적 변화에 따른 암거주변 흐름특성 실험연구)

  • Kim, Sung Joong;Yeo, Hong Koo;Kang, Jun Gu;Jung, Do Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.467-467
    • /
    • 2016
  • 암거는 일반적으로 용수나 배수용의 수로가 도로, 철도, 제방 등의 아래에 매설 된 수로를 지칭한다. 이러한 암거는 산업발전으로 사회기반시설의 신설 및 확충, 재정비 등으로 많이 활용되고 있다. 최근 들어 기후로 인한 재해가 급증하면서 이러한 시설물에 대한 안정성 및 관리에 대한 관심이 높아지고 있는 것이 현실이다. 특히 소하천은 집수면적 및 유로연장이 짧고 하상경사가 급하기 때문에 홍수에 취약하다. 즉, 빨라진 유속으로 인해 구조물 주변의 세굴에 의한 유실, 토사유출로 인한 하상퇴적, 부유물로 인한 차단으로 인해 통수에 지장을 받아 피해가 발생하게 된다. 이러한 암거시설물 피해는 2차 피해로 이어질 수 있으며 사회기반시설 파괴로 도시기능이 마비되고 인근 주변지역에 침수로 인한 재산 및 인명피해까지 발생시킬 수 있는 피해 잠재능력을 보유하고 있다. 그러나 피해에 대한 예방대책은 유지관리를 통해 지속적으로 관리하는 것이 대부분의 지침 등에 소개된 내용들이다. 본 연구에서는 암거를 대상으로 암거의 폐색으로 인해 암거주변에서 변화되는 흐름특성을 축소모형을 통해 검토하고자 하였다. 암거 축소모형실험은 1.5m 폭을 갖는 직선수로에서 수행하였으며, 암거모형은 도로암거표준도(2008)를 참조하여 $3m{\times}3m$ 수로암거를 대상으로 1/10 축소모형을 제작하였다. 암거유입부 퇴적으로 인한 암거의 차단률(차단면적/암거단면적)은 차단이 발생하지 않는 0% 조건에서부터 10%, 20%, 30%, 40%, 50% 조건에 대해 실험을 수행하였다. 실험결과 차단에 따른 암거 상류단의 수위는 차단이 없는 암거의 경우에 비해 차단율이 높아질수록 암거유입부 수위는 20.4% ~ 82.7% 상승하는 것으로 나타났다. 암거의 차단률이 40% 이상일 경우 높아진 수위로 인해 암거통로의 윗상면부까지 다다르고 있으며 50%일 경우 암거를 통과하는 흐름이 자유수면흐름이 아닌 오리피스 흐름이 발생하는 것으로 나타났다. 암거유입부 차단으로 인한 암거주변의 최대유속은 암거 직하류부에서 주로 발생하여 암거 유출부에서의 최대유속은 차단율이 증가할수록 선형적으로 증가하는 것으로 나타났으며 암거 유출부에서의 유속은 차단전의 조건(0%) 대비 4.2% ~ 35.5% 까지 상승하는 것으로 나타났다. 이와 같은 결과를 토대로 고려하였을 때 대부분 산지부에서 설치되는 암거의 경우 유속이 불가피하게 증가하게 됨으로 유속에 따른 유속조절방안(차단 및 우회시설) 및 세굴대책을 세워야 할 것으로 판단된다.

  • PDF

Experimental study on debris reduction facilities verification for small bridge and culvert (소교량 및 암거 대상 유송잡물 저감시설 검증실험)

  • Kim, Jong Tae;Yeo, Hong Koo;Kang, Jun Gu;Kim, Sung Joong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.447-447
    • /
    • 2016
  • 홍수 시 하천을 따라 유하되는 유송잡물(잡목, 생활쓰레기 등)은 구조물에 집적이 이루어지며 이로 인해 물의 흐름을 방해하고 구조물 주변의 지반을 약화시키거나 월류로 인해 심각한 피해를 야기 시킨다. 교량의 경우 유송잡물의 집적은 교각의 항력을 증가시켜 전도파괴를 유발시킬 수 있으며, 교각주변 흐름교란을 통한 하상세굴로 인해 기초부를 파괴시키기도 한다. 또한 통수단면적 증가로 인해 높아진 수위는 제방을 월류시켜 재산 및 인명피해를 유발하기도 한다. 암거의 경우 유송잡물을 포함한 토사로 인해 단면폐색 및 침식으로 암거의 파괴를 발생시키고 이로인해 도로의 단절을 가져오기도 한다. 이러한 유송잡물에 대한 차단대책은 현재 까지 유지관리를 통한 방법만이 최선책으로 제시되고 있다. 본 연구는 국외에서 소개되고 있는 유송잡물 피해저감시설을 대상으로 축소모형실험을 통해 효과를 확인하고 이를 통해 저감시설의 효율에 대해 소개하고자 하는 것이 주목적이다. 유송잡물 저감시설은 교량의 경우 수직분리대 방법, 우회말뚝 방법, 스위퍼를 이용한 방법으로 소개하고 있으며 이들 방법의 특징은 유송잡물 우회를 통해 집적을 저감하는 방식이다. 암거의 경우 수직분리대 방법, 스크린 방법, 우회스크린을 이용하는 방법 등이 있으며 수직분리대는 교량과 마찬가지로 우회방식을 기본방식으로 스크린 방식은 유송잡물의 차단을 원칙으로 하고 있다. 실험의 결과는 교량과 암거의 차단시설 유무에 따른 유송잡물의 집적률을 대상으로 하였다. 차단시설이 없는 경우 교량에서의 집적률은 97.9% ~ 99.2%의 집적률로 나타났다. 수직분리대의 경우 유송잡물 집적률은 49.3%, 우회말뚝은 0.0% ~ 4.2%의 범위로 매우 높은 차단효과를 보이고 있었다. 스위퍼방식의 경우 집적률은 5.3% ~ 20.9%로 나타났다. 이러한 결과로 판단하였을 때 차단시설 설치로 인한 교량에 대한 직접적인 차단효과는 수직분리대 < 스위퍼 < 우회말뚝 순으로 높은 차단효과를 보이는 것으로 나타났다. 그러나 우회말뚝에서의 집적률이 한계치를 넘어선다면 유송잡물로 인해 흐름교란, 수위 및 하상변동, 말뚝의 유실 등으로 인한 피해가 예상된다. 암거대상 유송잡물 차단시설 실험결과는 수직분리대의 경우 type과 투하방법에 따라 차이가 있지만 집적률은 14.7% ~ 64.9%의 범위로 나타났다. 스크린과 우회스크린 방식은 유송잡물의 우회가 아닌 차단이 목적이므로 유송잡물 집적에 의한 수위상승이 우려되는바 수위영향을 검토하였다. 검토결과 스크린 설치로 인한 수위상승이 우회스크린보다 높게 상승하는 것으로 나타났다. 이러한 결과는 스크린의 형태적인 측면에서 2면을 통해 집적되는 특성을 갖는 우회스크린이 통수단면적을 많이 확보하기 때문이다. 따라서 국부적인 수위상승으로 인한 피해를 저감하기 위해서는 설치여건이 허용된다면 통수단면적 확보가 유리한 우회스크린 설치가 유리할 것으로 판단된다.

  • PDF

Centrifugal Model Test on Behavior of Underground Corrugated Steel Plate with Compaction Degree (다짐도에 따른 지중파형강판의 거동에 대한 원심모형실험)

  • Heo, Yol;Kwon, Seonuk;Kim, Hongjong;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.10
    • /
    • pp.83-90
    • /
    • 2011
  • A series of centrifugal model test was conducted to investigate the distribution of vertical earth pressure on circular ductile underground corrugated steel plate waterway culvert with considering the compaction degree of the backfill in the high landfilled embankment section. The compaction degree of backfill was varied to 80, 85, 90, and 95% at the 53g-level gravity considering the similarity of the site. As a result of this test, the load reduction factor by the arching effect of the top of corrugated steel plate showing ductile behavior nearly agreed with the load reduction factor according to the compaction degree of backfill specified in the AISI(2002) design method. The vertical earth pressure measured at the top of the corrugated steel plate was linearly decreased as the compaction degree increased. The greater the compaction degree of backfill was, the greater the reduction of surface loading on the top of the corrugated steel plate by arching effect. The load decreased by arching effect on top of the corrugated steel plate was transferred to the side backfill of the corrugated steel plate(EP 1) and the outside of backfill(EP 3).

Investigation of Microorganism-Based Autonomous Crack Healing Agent and Full-scale Verification of Crack Healing (미생물 기반 자발적 콘크리트 균열치유제 성능 분석 및 실스케일 균열치유성능 검증)

  • Yeon-Jun Yoo;Byung-Jae Lee;Joo-Kyoung Yang;Yun Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.138-143
    • /
    • 2023
  • In this study, the crack healing performance of each crack healing agent manufacturing method was analyzed by adding crack healing agents in the form of alginate gel and spore suspension inoculated with endospores of calcium carbonate-forming bacteria to mortar. In addition, by applying it to an full-scale structure in the form of a box-type culvert, we attempted to create an environment in which the developed crack healing agent can be applied not only to a laboratory environment but also to an actual field. The crack healing agent using the dry heat drying method showed crack healing performance, but in the case of the freeze drying method, many spores were killed by freeze hardening and therefore the crack healing performance was lost. As a result of SEM and XRD pattern analysis of the presumed crack healing material extracted from the crack of a full-scale structure, it was found to be calcite, one of the calcium carbonate crystals produced by microorganisms applied to the crack healing agent. In conclusion, it was found that the crack healing by microorganisms can be implemented in a real structure.

The Efficiency and Improvement of the Highway Wild-Life Fences for Decrease of Mammals Road-kill - In Case of Manjong~Hongchun Section on Jungang Highway - (포유류 로드킬 저감을 위한 고속도로 유도울타리 효율성 및 개선방안 연구 - 중앙고속도로 만종~홍천 구간을 사례로 -)

  • Song, Jeong-Seok;Lee, Kyong-Jae;Ki, Kyong-Seok;Jun, Ik-Yo
    • Korean Journal of Environment and Ecology
    • /
    • v.25 no.5
    • /
    • pp.649-657
    • /
    • 2011
  • This study had targeted the Manjong Junction~Hongchun interchange section of Jungang highway in order to analyze the efficiency and improvement of the highway wild-life fences. Being analyzed wild-life fence as an effective facility for the prevention of road-kill, it had founded that the wild animals did not jump over even the two layer guardrail, concrete barrier and noise barrier, fence for rock fall. For the section with high road-kill decrease effect after installing the wild-life fence, the effect was higher at wild-life fence with the height of 1.0m where the door had not been installed and the well connected points of road facility than the area with fence height of 1.5m. The road-kill decrease effect was also high at the well managed areas even if the door has not been installed. Also, road-kill had occurred by concentrating around the end of wild-life fence after installing the fence, Moreover road-kill had also occurred around the cutting section. The door of wild-life fence had higher amount of road-kill occurrence as the installation interval was closer. it was analyzed that the door management has a lot of effect on road-kill decrease. The fence for rock fall, two layer guardrail and concrete barrier having the effect of wild-life fence installed on the road would have to be installed by connecting with wild-life fences through proper facility improvement. Although the door should not be installed if possible, it should be installed as automatic door or gravity door to prevent the door from leaving the door open. An escape route has to be formed for the prompt escape away from the road for the animals entered through the ending section of the fence. The eco-corridor has to be made by restoring the soil layer of dual purpose eco-corridor forming a planting area. Also, the dead body after the accident has to be disposed to the outer section of the road immediately in order to prevent the secondary road-kill by the predator from the road-kill. The fence has to be installed as 500m or longer in both ways, in other words 1,000m or longer, from the targeted spot of minimum accident prevention while connecting up to the bridge or box culvert, etc that are next road facilities if possible to guide wild animals safely to the eco-corridor.

A Study on the Composition Principle of the Gyeongbokgung Drainage Facility - Focused on the review of Gyeongbokgung excavation survey - (경복궁(景福宮) 배수시설(排水施設)의 조성원리(造成原理)에 관한 연구 - 경복궁 발굴조사 자료에 대한 검토를 중심으로 -)

  • Kim, Tae Min;Nam, Ho Hyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.4
    • /
    • pp.120-145
    • /
    • 2018
  • This study intended to examine the drainage facility of Gyeongbokgung Palace based on the traces of the relic found during the excavation survey. Historical records indicate that various efforts have been made for smooth drainage facility for the palace since the foundation of the Joseon Dynasty. Although there are no drawings showing the image of early appearance of Gyeongbokgung Palace during the foundation, it is possible to estimate it through the drawings prepared after the King Yeongjo's reign. The image of the palace after reconstruction can be seen through the "Bukgwoldohyeong" and other relevant documents. At this present, since the survey intends to determine the image of Gyeongbokgung Palace during the reign of King Gojong based on the standard restoration plan of the Cultural Heritage Administration, this study also focused on the drainage facility of Gyeongbokgung Palace during King Gojong's reign, particularly on the collecting wells and culverts of six areas including "Chimjeon Hall", "Taewonjeon Hall", "Geoncheongung Hall", "Sojubang Hall", "Hamhwadang - Jipgyeongdang - Yeonghundang Hall", and "Heungbokjeon Hall". Gyeongbokgung Palace is divided into various zones composed of the central halls and surrounding corridors, and the drains also primarily start from each hall and later join the central drain of the zone. The central drain then leads to the "Eo-gu(御溝)" and the water led to the "Eo-gu" is finally discharged through the water gate. It appears that this series of processes were basically devised to coordinate artificial drain with the natural drain using the natural geographical features of the palace. Research showed that the collecting well where the draining begin was installed in the area where a large amount of household sewage was generated but mostly in the corners where corridors met or corridors and wall met. This appears to be an arrangement to handle the water falling from the roof and household sewage. Also, "Ju(廚)" was installed mainly at the end of the corridor to handle household sewage. The installation of these drainage facilities shows the possibility that the drainage of Gyeongbokgung was very compact under a series of plans.

A Study on the Characteristics and Model of Lotus Pond in Joseon Royal Tombs (조선왕릉 연지(蓮池)의 특성과 전형)

  • Ko, Seung-Kwan;Koo, Bon-Hak;Choi, Jong-Hee
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.29 no.3
    • /
    • pp.116-123
    • /
    • 2011
  • This study investigates the characteristics(form, material, structure, method of construction, vegetation) and model of lotus pond in Joseon Royal Tombs for conservation and restoration. The objects of study are the lotus pond of Namyangju Gwangreung, Hyoreung, Gimpo Jangreung and Sungreung that are well-preserved and the record is remaining. The form is two plane types, square shaped include an island and square shaped. The pond is 7.5~81m in width and 6.5~45m in length and the island is 8~16m in diameter. The depth of water is 0.5~1.2m and the cross section form is narrow bottom and wide top. The material of shore protection is soil in Hyoreung, Gimpo Jangreung and Sungreung. The bottom is mud in all sites. I think that the main material of the lotus pond in Joseon Royal Tombs is soil. The lotus pond is built by soil bank in the structure and method of construction. The water supply and drainage are worked through the culvert. There are many kinds of plants in the lotus pond today, however I think that the model of vegetation of lotus pond in Joseon Royal Tombs is lotus the inside, pine tree, fir tree and flowers the around and pine tree the inside of island in compared the present and the old literature. In comparison with the lotus pond in Joseon Royal Tombs and the lotus pond in the Joseon palace, the material is the biggest difference. The main material is soil in Royal Tombs but isodomic in Royal Palace. I think that the difference of material in between two causes the difference of structure and method of construction. The Royal Tombs is valuable in architecture, landscape and esthetics, this study investigated the characteristics and model of lotus pond in Joseon Royal Tombs. I think that this study serves as a momentum to find a traditional technique in Royal water space and offer the foundation to plan in the contemporary water space.