• Title/Summary/Keyword: Cu/CoFe 다층박막

Search Result 31, Processing Time 0.031 seconds

MAGNETIC PROPERTIES OF THERMALLY ANNEALED $(Ni_{80}Fe_{20})_{1-x}Mn_x$ THIN FILMS

  • Kim, K. K.;Kim, C. K.;C. S. Yoon;Kim, S. J.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.190-191
    • /
    • 2002
  • Granular feromagnets는 non-magnetic maxtrix 안에 nanometer-sized의 ferromagnetic grain들 구성된다. Co-Cu,Co-Ag, Fe-Ag, NiFe-Ag $^1$을 포함하는 이미 알려진 다른 Granular 금속 합금들의 giant magnetoresistance 에 관계하여 Granular feromagnets 에 대해 조사하였다. Bulk상태의 NiFe와 Mn 혼화되기 쉽다.$^2$ 그리고 Mn은 열처리된 다층박막의 NiFe의 lattice에 쉽게 수용되어진다.$^3$ 이번 실험에서는 metastable한 fcc solid solution NiFe-Mn 박막이 열처리 하에서 NiFe과 Mn으로 분리되었다. (중략)

  • PDF

Magnetoresistance Effect of [Pd/Co] Spin-valve with Perpendicular Anisotropy (수직자기이방성을 갖는 [Pd/Co] Spin Valve 구조에서 자기저항효과)

  • Choi, Jin-Hyup;Lee, Ky-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.173-177
    • /
    • 2006
  • We have investigated the magnetoresistance (MR) effect of the spin valve structures composed of perpendicularly magnetized Pd/Co multilayers, with changing the space layer (Pd or Cu) thickness, the stacking number of the Pd/Co multilayers, and the Co insertion-layer thickness. The Cu space layer showed larger MR ratio than the Pd space layer. The Co insertion-layer between Cu layer and pinned layer enhanced the MR ratio about three times. The maximum MR ratio of 7.4 % was established in the sample with the Co insertion-layer thickness of 0.62 and 1.01 nm.

Coersivity Alteration of Free Layer in the [Co/Pd] Spin-valves with Perpendicular Magnetic Anisotropy ([Pd/Co] 다층박막을 이용한 수직스핀밸브 구조에서 비자성층에 인접한 강자성 물질과 그 두께에 따른 자유층의 보자력 변화)

  • Heo, Jang;Choi, Hyong-Rok;Lee, Ky-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.89-93
    • /
    • 2010
  • We study the giant magneto-resistance (GMR), coercivity and their dependence on the ferromagnetic layers adjacent to the nonmagnetic layer in a spin-valve structure, [Pd/ferromagnetic] multilayers with perpendicular anisotropy. We fabricated a basic spinvalve structure of $[Pd/Co]_2$/ferro-magnetic layer/nonmagnet/ferro-magnetic layer/$[Pd/Co]_2$/FeMn and investigated the dependence of its GMR and magnetic properties such ad coercivity on the ferromagnetic material to reduce the coercivity of the free layer. We try to reduce the freelayer coercivity by controlled the anisotropy, we insert the material NiFe, $Co_8Fe_2$, $Co_9Fe_1$ to ferromagnetic layers adjacent to the Cu layer. Then, we have been able to reduce the coercivity as low as 100 Oe, and also achieved 6.7% of magneto-resistance ratio when the ferromagnetic layer thickness was 0,7 nm.

The Effect of Residual Stress on Magnetoresistance in GMR Head Multilayers (자기기록 MR 헤드 용 다층박막의 자기저항에 미치는 잔류응력 효과)

  • Hwang, Do-Guwn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.322-327
    • /
    • 2003
  • Giant magnetoresistance(GMR) NiO multilayer, which has been used to reading head of highly dense magnetic recording, was fabricated, and oxidized in an air during 80 days to study the dependence of magnetoresistance properties on residual stress in the interfaces. The magnetoresistance ratio and the exchange biasing $field(H_{ex})$ of $NiO(60nm)/Ni_{81}Fe_{19}(5nm)/Co(0.7nm)/Cu(2nm)/Co(0.7nm)/Ni_{81}Fe_{19}(7nm)$ spin valves were increased from 4.9% to 7.3%, and 110 Oe to 170 Oe after natural oxidation in the atmosphere for 80 days, respectively. The sheet resistivity ${\rho}$ decreased from $28{\mu}{\Omega}m$ to $17{\mu}{\Omega}m$, but ${\Delta}p$ did not almost change after the oxidation. Therefore, the increase of MR ratio is due to the decrease in the sheet resistivity. the reduced resistance may result from the increase in the reflection of conduction electrons at the oxidized top surface. Also, the increase in the exchange biasing field is originated from the reduction of residual stress at the interface of $NiO/Ni_{81}Fe_{19}$ according as the aging time increases.

Magnetoresistance Properties of Hybrid GMR-SV Films with Nb Buffer Layers (Nb 버퍼층과 거대자기저항-스핀밸브 하이브리드 다층박막의 자기저항 특성)

  • Yang, Woo-Il;Choi, Jong-Gu;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.3
    • /
    • pp.82-86
    • /
    • 2017
  • The IrMn based GMR-SV films with three different buffer layers were prepared on Corning glass by using ion beam deposition and DC magnetron sputtering method. The major and minor magnetoresistance curves for three different buffer layers beneath the structure of NiFe(15 nm)/CoFe(5 nm)/Cu(2.5 nm)/CoFe(5 nm)/NiFe(7 nm)/IrMn(10 nm)/Ta(5 nm) at room temperature have shown different magnetoresistance properties. When the samples were annealed at $250^{\circ}C$ in vacuum, the magnetoresistance ratio, the coercivity of pinned ferromagnetic layer, and the interlayer coupling field of free ferromagnetic layer were enhanced while the exchange bias coupling field did not show noticeable changes.

Magnetoresistive Properties of Array IrMn Spin Valves Devices (어레이 IrMn 스핀밸브 소자의 자기저항특성 연구)

  • Ahn, M.C.;Choi, S.D.;Joo, H.W.;Kim, G.W.;Hwang, D.G.;Rhee, J.R.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.156-161
    • /
    • 2007
  • To develop array magnetic sensors, specular-type giant magnetoresistive- spin valve (GMR-SV) film of Glass/Ta(5)MiFe(7)/IrMn(10)NiFe(5)/$O_2$/CoFe(5)/Cu(2.6)/CoFe(5)/$O_2$/NiFe(7)/Ta(5)(nm) was deposited by using a high-vacuum sputtering system. One of 15 way sensors in the area of $8{\times}8mm^2$ was Patterned a size of $20{\times}80{\mu}m^2$ in multilayer sample by Photo-lithography. All of 15 sensors with Cu electrodes were measured a uniform magnetic properties by 2-probe method. The highest magnetic sensitivity of MR and output voltage measured nearby an external magnetic field of 5 Oe were MS = 0.5%/Oe and ${\triangle}$V= 3.0 mV, respectively. An easy-axis of top-free layers of $CoFe/O_2/NiFe$ with shape anisotropy was perpendicular to one of bottom-pinned layers $IrMn/NiFe/O_2/CoFe$. When the sensing current increased from 1 mA to 10 mA, the output working voltage uniformly increased and the magnetic sensitivity was almost stable to use the nano-magnetic devices with good sensitive properties.

Post-annealing Effect of Giant Magnetoresistance-Spin Valve Device for Sensor (센서용 거대자기저항 스핀밸브소자의 열처리 효과)

  • Lee, Sang-Suk;Park, Sang-Hyun;Soh, Kwang-Sup;Joo, Ho-Wan;Kim, Gi-Wang;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.4
    • /
    • pp.172-177
    • /
    • 2007
  • In order to detect of the magnetic property in the cell unit, we studied the GMR-SV (giant magnetoresistance-spin valves) biosensor, which was depended on the micro patterned features according to two easy directions of longitudinal and transversal axes. Here, the multi layer structure was glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe. The uniaxial anisotropy direction was applied to the patterned biosensor during the deposition and vacuum post-annealing at $200^{\circ}C$ under the magnitude of 300 Oe, respectively. Considering the magnetic shape anisotropy effect, the size of micro patterned biosensor was a $2{\times}5{\mu}m^2$ after the photo lithography process. By our experimental results, we confirmed that the best condition of GMR-SV biosensor should be the same direction of the axis sensing current and the easy axis of pinned NiO/NiFe/CoFe triple layer oriented to the width direction of device, and the direction of the easy axis of free CoFe/NiFe bilayer was according to the longitudinal direction of device.

Exchange Coupling in CoZr/Ag/CoCr Trilayered Films (CoZr/Ag/CoCr 삼층박막의 교환결합)

  • 백종성;박용성;임우영;이수형;김종오
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.357-361
    • /
    • 1998
  • For CoZr/Ag/CoCr trilayered films deposited by DC and FR magnetron sputtering method, ferromagentic resonance experiments have been used to investigate the dependence of the exchange coupling between CoZr and CoCr layers separated by Ag layer on the thickness of the Ag layer. The coupling strength K increases with increasing Ag thickness up to 10 $\AA$ with a maximum value of 748 Oe, but oscillates with increasing Ag thickness in the range from 20 to 100 $\AA$. The coupling strength is positive for all samples. Hence, it seems that the exchange coupling between CoZr and CoCr layers separated by Ag layer is ferromagnetic.

  • PDF