• Title/Summary/Keyword: Cross-contamination

Search Result 264, Processing Time 0.024 seconds

A Study on the Characteristics of Cross-contamination according to the Size and Separation distance of Exterior Air-vents (실외 급배기구 크기와 이격거리에 따른 교차오염 특성연구)

  • Moon, Yong-Jun;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.393-398
    • /
    • 2006
  • This study is undertaken to evaluate the characteristics of cross contamination around exterior air-vents. A CFD analysis has been performed to calculate the cross contamination index for five exterior air-vents sizes according to the outdoor air velocity and separation distance of it. From the result of the numerical method, As the outdoor air velocity is increased, the cross contamination index is increased. on the contrary, as the separation distance of exterior air-vents is increased, the cross contamination index is decreased, additionally the cross contamination is affected by the aspect ratio of the size of exterior Air-vents.

  • PDF

Evaluation of Salmonella cross contamination at retail chicken meat outlets in Kandy, Sri Lanka

  • Alwis, Upeksha S.;Mudannayake, Deshani C.;Jayasena, Dinesh D.;Ubeyarathna, Kamalika J.H.
    • Korean Journal of Agricultural Science
    • /
    • v.41 no.1
    • /
    • pp.35-40
    • /
    • 2014
  • This study was carried out to evaluate the Salmonella cross contamination at retail chicken meat outlets in Kandy, Sri Lanka and to identify the risk factors for Salmonella contamination at retail chicken meat outlets. Fifteen retail chicken meat outlets in Kandy area were randomly selected. Pre-tested questionnaires were used to collect data for identifying risk factors of Salmonella cross contamination at retail outlets and swab samples from meat contact surfaces/utensils were obtained. Out of 57 swab samples collected from meat contact surfaces/utensils, the overall prevalence of Salmonella cross contamination was 21%. Weighing scale (33%), meat containing trays/buckets (27%) and cutting board (25%) showed the highest percentage of Salmonella prevalence whereas knife and showcase showed relatively low percentages, 14% and 9%, respectively. Retail chicken outlets with slaughtering facilities had a significantly higher prevalence of Salmonella cross contamination than those without slaughtering facilities. This higher rate of Salmonella cross contamination at retail chicken meat outlets could be attributed to lack of proper cold chains and minimal facilities, and poor level of hygiene in those outlets.

Investigation of Microbial Contamination and Working Environment in University Foodservices (대학급식소 작업시설과 환경의 미생물 오염도 분석 및 작업환경 실태조사)

  • Park, Soon-Hee;Moon, Hye-Kyung
    • Journal of the Korean Dietetic Association
    • /
    • v.23 no.2
    • /
    • pp.180-191
    • /
    • 2017
  • The purpose of this study was to identity the probability of cross-contamination from the environment. For this, we examined foodservices at 20 universities/colleges for microbiological analysis of their working facilities and environment as well as their preventive equipment against cross-contamination. Seventy percent of the 20 foodservices were found to maintain one unified working area, which suggests high probability of contamination of food/utensils/equipment in the cooking area by pre-preparation or dish washing. According to the microbiological analysis, the hygiene acceptance ratio of working facilities in the clean zone was 70%, which was higher than the average 45% hygiene acceptance ratio of working facilities in the contamination operating zone. There was a significant difference in the total plate count (P<0.001) and coliform count (P<0.01), which demonstrates that work tables in the clean zone were in a good state compared to those in the contamination operating zone. In the contamination operating zone, refrigerator shelves had a high probability of cross-contamination. Regarding the floor surface and airborne microbes, cooking areas which should be maintained as clean zones had higher cross-contamination probability than those in the contamination operating zone. So corrective actions such as cleaning and sanitizing, keeping dry floors, lowered temperature and humidity, shoe disinfecting facilities, and checking concentrations, are necessary to manage floor surfaces and airborne microbes in the cooking area.

Effects of ionized calcium on microbial cross-contamination in surface of carcass via slaughter process of chickens (이온화칼슘이 도계과정 중 도체표면의 미생물 교차오염에 미치는 영향)

  • Park, B.S.;Jin, J.Y.
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.813-823
    • /
    • 2016
  • The purpose of this study was to investigate the effects of ionized calcium treatment on total bacterial cross-contamination of chicken carcass surface in the slaughtering process. The growth of Escherichia coli was strongly inhibited in a medium prepared by using a 0.5% ionized calcium solution. The total bacterial cross-contamination of chicken carcass surface and the scalding water was significantly increased as the number of scalding was increased (p<0.05). The total bacterial cross-contamination of chicken carcass surface reached a plateau without a further increase as scalding was performed consecutively for 10 or more times. The total bacterial cross-contamination of the scalding water was significantly increased as the number of scalding was increased (p<0.05). The total bacterial cross-contamination of chicken carcass surface of the chickens raised on a floor type farm was significantly higher than that of the chickens raised in a battery cages (p<0.05). The total bacterial cross-contamination of chicken carcass surface of the chickens raised on a floor type farm was significantly lower in the 0.5% ionized calcium solution treatment group than in the control group (p<0.05).

A Study on the 3-D Airflow and Dynamic Cross Contamination in the Photolithography Process Cleanroom (광식각공정이 있는 클린룸에서의 3차원 기류 및 동적교차오염에 관한 연구)

  • Noh, Kwang-Chul;Oh, Myung-Do;Lee, Seung-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.560-568
    • /
    • 2004
  • We performed the numerical study on the characteristics of the 3-D airflow and dynamic cross contamination in the photolithography process cleanroom. The nonunifurmity, the deflection angle and the global cross contamination were used for analyzing the characteristics and performances of cleanroom. From the numerical results, we knew that the airflow characteristics of the cleanrooms are largely affected by the porosity of panel and the adjustment of dampers and the global cross contamination varies with the location of source and the passage of time through the concentration ratio.

A Numerical Study on the Characteristics of Airflow and Cross Contamination in the Photolithography Process Cleanroom (광식각공정 클린룸에서의 기류 및 교차오염에 대한 수치적 연구)

  • Noh, Kwang-Chul;Lee, Seung-Chul;Oh, Myung-Do
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.151-156
    • /
    • 2003
  • We performed the numerical study on the characteristics of the airflow and cross contamination in the photolithography process cleanroom. The nonuniformity, the deflection angle and the global cross contamination were used for analyzing the characteristics and performances of cleanroom. We knew that the airflow characteristics of the cleanrooms are largely affected by the porosity of panel and the adjustment of dampers. And the numerical result showed that the global cross contamination varies with the location of source and the passage of time.

  • PDF

Studies on the HACCP Model of Steak-Set Menu in Hotel (HACCP 모델 적용시 호텔 .레스토랑의 세트 메뉴 중 스테이크에 관한 연구)

  • 양신철
    • Journal of Applied Tourism Food and Beverage Management and Research
    • /
    • v.12 no.1
    • /
    • pp.5-24
    • /
    • 2001
  • This study was focused on the sanitary analysis of hazard factors and the establishment of critical control points on steak-set menu In hotel by the documents and microbiological investigation. The hazard factors of shrimp cocktail were microbial contamination, residual pesticides, unsuitable healing and cross contamination. The hazard factors of potato soap were residual pesticides, microorganisms contamination, unsuitable heating and solanine in potato. The hazard factors of simple salad were microorganisms contamination, unsuitable heating and cross contamination by inappropriate package. The hazard factors of steal were residual antimicrobial drugs, microorganisms contamination, unsuitable heating and cross contamination. The critical control points of shrimp cocktail were temperature control , number of washing and center temperature control of heating step. The critical control points of potato soup were stock temperature control , number of washing and center temperature control of Heating step. The critical control points of simple salad were number of washing and dryness of utensil. The critical control points of steak were stock temperature control , number of washing, center temperature and time control of heating step.

  • PDF

A Study on the Space Planing for Restaurant Kitchens to Improve Hygiene (식당 주방의 위생 향상을 위한 공간계획에 관한 연구)

  • Lee, Jong-Ran
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2011
  • This research proposed the space planing methode and diagrams of restaurant kitchens to improve hygiene by analyzing the related contents collected from books and researches in interior design and HACCP (Hazard Analysis and Critical Control Point). HACCP is an effective and scientific hygiene system for food safety in order to prevent cross-contamination from food hazards. Based on the analyses, improvement of food production environments like restaurant kitchens is necessary for food hygiene. The space planing methode of restaurant kitchens to improve hygiene are followings: The circulation planing is that the direction of movement of the food, workers, waste, and dishes should be fractionated and managed for cross-contamination prevention. The space separation planing is that the spaces in the kitchen should be classified and divided into contaminated area and non-contaminated and clean area depending on the degree of cleanliness. The zoning is space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination disappear in kitchen. However, if cross-contamination is unavoidable in some points in restaurant kitchens, hygiene facilities such as washing rooms, pass rooms, and double doors with air-shower should be located in order to remove contamination.

Fabrication Method of High-density and High-uniformity Solder Bump without Copper Cross-contamination in Si-LSI Laboratory (실리콘 실험실에 구리 오염을 방지 할 수 있는 고밀도/고균일의 Solder Bump 형성방법)

  • 김성진;주철원;박성수;백규하;이희태;송민규
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.4
    • /
    • pp.23-29
    • /
    • 2000
  • We demonstrate the fabrication method of high-density and high-quality solder bump solving a copper (Cu) cross-contamination in Si-LSI laboratory. The Cu cross-contamination is solved by separating solder-bump process by two steps. Former is via-formation process excluding Cu/Ti under ball metallurgy (UBM) layer sputtering in Si-LSI laboratory. Latter is electroplating process including Ti-adhesion and Cu-seed layers sputtering out of Si-LSI laboratory. Thick photoresist (PR) is achieved by a multiple coating method. After TiW/Al-electrode sputtering for electroplating and via formation in Si-LSI laboratory, Cu/Ti UBM layer is sputtered on sample. The Cu-seed layer on the PR is etched during Cu-electroplating with low-electroplating rate due to a difference in resistance of UBM layer between via bottom and PR. Therefore Cu-buffer layer can be electroplated selectively at the via bottom. After etching the Ti-adhesion layer on the PR, Sn/Pb solder layer with a composition of 60/40 is electroplated using a tin-lead electroplating bath with a metal stoichiometry of 60/40 (weight percent ratio). Scanning electron microscope image shows that the fabricated solder bump is high-uniformity and high-quality as well as symmetric mushroom shape. The solder bumps with even 40/60 $\mu\textrm{m}$ in diameter/pitch do not touch during electroplating and reflow procedures. The solder-bump process of high-uniformity and high-density with the Cu cross-contamination free in Si-LSI laboratory will be effective for electronic microwave application.

  • PDF

A Study on Hygienic Space Planing of a University Student Restaurant - Focused on the customer space in E University Student Restaurant in Seoul Applying HACCP - (대학 학생 식당의 위생적 공간 계획에 관한 연구 - 서울 E 대학 학생 식당 고객 공간에 HACCP 적용 중심으로 -)

  • Lee, Jong-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.182-189
    • /
    • 2011
  • This research suggests a way of hygienic space planing of the customer space in the university student restaurant of E University in Seoul. For this study. the behavior observation in the restaurant was conducted in order to analyze the sequence of customer behavior related space planing applying HACCP (Hazard Analysis And Critical Control Point). Also the survey was conducted to analyze opinions of customers about hygiene of the space. The results of the analyses of the observation and the survey were similar in terms of hygiene. In conclusion, for hygienic space planing of the customer space in restaurant, the space circulation should be planned according to the hygienic sequence of customer behavior. The spaces in restaurant should be divided into two areas: the clean area and the contaminated area to prevent cross-contamination. The clean area, such as spaces preparing dishes and food including water and table hall where customers eat, should be separated from the contaminated area such as the spaces where waste is handled and where dirty dishes are kept. In order to prevent cross-contamination, hygiene facility to remove contamination should be located before going to the clean area. More specifically, the hygiene facility should be located between a cash counter and a space preparing dishes so that customers can wash their hands before they touch dishes. Space arrangement with feed-back process to check the possible points of cross-contamination and correct space arrangement until the possibility of cross-contamination is removed in the restaurant.