• 제목/요약/키워드: Cross Type Beam

검색결과 169건 처리시간 0.027초

냉음극형 대면적 펄스 전자빔 가속기의 빔인출 특성 (Characteristics of Electron Beam Extraction in Cold Cathode Type Large Cross-Sectional Pulsed Electron Beam Generator)

  • 우성훈;이광식;이동인;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1609-1611
    • /
    • 2001
  • A large cross-section pulsed electron beam generator of cold cathode type has been developed for industrial applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. The conventional electron beam generators need an electron scanning beam because the small cross section thermal electron emitter is used. The electron beam of large cross-section pulsed electron beam generator do not need to be scanned over target material because the beam cross section is large by 300$cm^2$. We have fabricated the large cross-sectional pulsed electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large area electron beam in the air. The electron beam current has been investigated as a function of accelerating voltage, glow discharge current, helium pressure, distance from the exit window and radial distribution in front of the exit window.

  • PDF

Band Plate로 연결된 RC기둥-철골보 접합부의 이력거동에 관한 실험연구 (Structural Behavior of the RC Column-Steel Beam Joint with Band Plate)

  • 서수연;이원호;이리형;윤승조
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권1호
    • /
    • pp.213-221
    • /
    • 2002
  • This paper presents the experimental result of Reinforced Concrete column-steel beam joint connected by Band Plates(BP). Main parameters in the test are the shape of BP and thickness of plate. Ten interior and exterior RC column-steel beam joint specimens are designed. Cyclic loads are applied to the beam end of eight specimens (four interior specimens and four exterior specimens). To evaluate the cyclic effect, monotonic loads are acted for two specimens. All specimen showed similar failure pattern such as the plate of BP get torn after the large deformation. Even though the specimen with double cross type BP has lower strength than the specimen with single cross type BP, the energy dissipation capacity of the specimen turned out high. Thus, provided the strength of joint with double cross type to be designed to have suitable strength by increasing the thickness of plate, the joint system may show higher seismic capacity.

Tubular composite beam-columns of annular cross-sections and their design practice

  • Kvedaras, A.K.;Kudzys, A.
    • Steel and Composite Structures
    • /
    • 제10권2호
    • /
    • pp.109-128
    • /
    • 2010
  • The expediency of using tubular composite steel and concrete columns of annular cross-sections in construction is discussed. The new type space framework with tubular composite columns of multi-storey buildings and its rigid beam-column joints are demonstrated. The features of interaction between the circular steel tube and spun concrete stress-strain states during the concentrical and eccentrical loading of tubular composite members are considered. The modeling of the bearing capacity of beam-columns of composite annular cross-sections is based on the concepts of bending with a concentrical force and compression with a bending moment. The comparison of modeling results for the composite cross-sections of beam-columns is analysed. The expediency of using these concepts for the limit state verification of beam-columns in the methods of the partial safety factors design (PSFD) legitimated in Europe and the load and resistance factors design (LRFD) used in other countries is presented and illustrated by a numerical example.

Analysis of rotational end restraint for cross-beams of railway through truss bridges

  • Siekierski, Wojciech
    • Steel and Composite Structures
    • /
    • 제35권1호
    • /
    • pp.29-41
    • /
    • 2020
  • Cross-beams of modern through truss bridges are connected to truss chord at its nodes and between them. It results in variable rotational end restraint for cross-beams, thus variable bending moment distribution. This feature is captured in three-dimensional modelling of through truss bridge structure. However, for preliminary design or rapid assessment of service load effects such technique of analysis may not be available. So an analytical method of assessment of rotational end restraint for cross-beam of through truss bridges was worked out. Two cases - nodal cross-beam and inter-nodal cross-beam - were analyzed. Flexural and torsional stiffness of truss members, flexural stiffness of deck members and axial stiffness of wind bracing members in the vicinity of the analyzed cross-beam were taken into account. The provision for reduced stiffness of the X-type wind bracing was made. Finally, general formula for assessment of rotational end restraint was given. Rotational end restraints for cross-beams of three railway through truss bridges were assessed basing on the analytical method and the finite element method (three-dimensional beam-element modelling). Results of both methods show good agreement. The analytical method is able to reflect effects of some structural irregularities. On the basis of the obtained results the general values of rotational end restraint for nodal and inter-nodal cross-beams of railway through truss bridges were suggested.

복합재료 H-형 단면 보의 동적응답 해석 (Dynamic Response Analysis of Composite H-type Cross-section Beams)

  • 김성균;송오섭
    • 한국소음진동공학회논문집
    • /
    • 제20권6호
    • /
    • pp.583-592
    • /
    • 2010
  • Equations of motion of thin-walled composite H-type cross-section beams exposed to concentrated harmonic and non-harmonic time-dependent external excitations, incorporating a number of nonclassical effects of transverse shear, primary and secondary warping, and anisotropy of constituent materials are derived. The forced vibration response characteristics of a composite H-type cross-section beam exhibiting the circumferentially asymmetric stiffness(CAS) configuration are exploited in connection with the structural bending-torsion coupling resulting from directional properties of fiber reinforced composite materials.

Variable kinematic beam elements for electro-mechanical analysis

  • Miglioretti, F.;Carrera, E.;Petrolo, M.
    • Smart Structures and Systems
    • /
    • 제13권4호
    • /
    • pp.517-546
    • /
    • 2014
  • This paper proposes a refined electro-mechanical beam formulation. Lagrange-type polynomials are used to interpolate the unknowns over the beam cross section. Three- (L3), four- (L4), and nine-point(L9) polynomials are considered which lead to linear, bi-linear, and quadratic displacement field approximations over the beam cross-section. Finite elements are obtained by employing the principle of virtual displacements in conjunction with the Carrera Unified Formulation (CUF). The finite element matrices and vectors are expressed in terms of fundamental nuclei whose forms do not depend on the assumptions made. Additional refined beam models are implemented by introducing further discretizations, over the beam cross-section. Some assessments from bibliography have been solved in order to validate the electro-mechanical formulation. The investigations conducted show that the present formulation is able to detect the electro-mechanical interaction.

일정체적 원호형 곡선보의 자유진동 (Free Vibrations of Circular Curved Beams with Constant Volume)

  • 이병구;이태은;최종민;박창은
    • 한국소음진동공학회논문집
    • /
    • 제21권6호
    • /
    • pp.570-579
    • /
    • 2011
  • This paper deals with free vibrations of the circular curved beams with constant volume, whose cross sectional shapes are the circular solid cross-sections. Volumes of the objective beam are always held in constant regardless shape functions of the cross-sectional radius. The shape functions are chosen as the linear, parabolic and sinusoidal ones. Ordinary differential equations governing free vibrations of such beam are derived and solved numerically for determining the natural frequencies. In numerical examples, the hinged-hinged, hinged-clamped and clamped-clamped end constraints are considered. As the numerical results, relationships between frequency parameters and various beam parameters such as rise ratio, section ratio, elasticity ratio, volume ratio, slenderness ratio and taper type are reported in tables and figures.

복합재료 H형 단면 보의 자유진동 해석 (Free Vibration Analysis of Composite H-Type Cross-section Beams)

  • 김성균;송오섭
    • 한국소음진동공학회논문집
    • /
    • 제20권5호
    • /
    • pp.492-501
    • /
    • 2010
  • Equations of motion of thin-walled composite H-type cross-section beams incorporating a number of nonclassical effects of transverse shear and primary and secondary warping, and anisotropy of constituent materials are derived. The vibrational characteristics of a composite thin-walled beam exhibiting the circumferentially asymmetric stiffness system(CAS) and the circumferentially uniform stiffness system(CUS) are exploited in connection with the bending-transverse shear coupling and the bending-twist coupling resulting from directional properties of fiber reinforced composite materials.

모듈러 골조용 비대칭 기둥-보 접합부에 대한 거동 평가 (Behavior Evaluation on the Non-symmetric Composite Column for Unit Modular Frames)

  • 박금성;이상섭;배규웅;문지호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권1호
    • /
    • pp.36-44
    • /
    • 2019
  • 본 연구의 목적은 강 - PC 복합모듈 골조를 구성하는 프레스 성형된 비대칭 기둥과 보 접합부의 구조적 성능을 평가하는 것이다. 모듈러 골조를 구성하는 대부분의 접합부는 폐쇄형의 사각형 강재 기둥 단면을 주로 사용한다. 폐쇄형의 기둥 단면을 사용한 기둥-보 접합부는 시공성을 감소시키고 내화성을 확보하는데 어려움이 있다. 이러한 단점을 극복하기 위하여 강판을 프레스로 성형하여 비대칭 개방형 단면 내에 콘크리트를 충진하는 것이다. 프레스 성형된 비대칭 기둥-보 접합부의 구조적 성능을 조사하기 위해 총 4개의 실험체를 제작하였다. 실험결과, 비대칭 기둥의 구조적 성능과 거동이 비대칭 기둥 단면이 합성되는지 또는 기둥의 폭-두께 비율에 따라 달라지는지를 보여주었다. 프레스 성형된 비대칭 기둥-보 접합부의 구조적 성능은 실험결과와 이론식을 비교하여 평가하였다.

비대칭 H형강 합성보의 단면형상변화에 따른 온도특성 및 화재거동에 관한 실험적 연구 (An Experimental Study on the Fire Resistance behaviour of Asymmetric Slimfloor Beam According to Cross Section Shape Variation)

  • 김형준;김흥열;이재승;권기혁;여인환
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.23-30
    • /
    • 2012
  • 비대칭 H형강이 콘크리트에 매립되어 화재에 노출되는 일반 합성보에 비하여 내화성능이 높은 슬림플로어 공법에 대한 화재거동특성을 분석하고, 이를 기반으로 내화성능을 향상시킬 수 있는 최적 단면형상 조건을 도출하고자 연구를 수행하였다. 단면형상은 휨 성능을 증진시킬 수 있는 웨브 보강과 화재에 직접 노출되는 하부플랜지의 보강 방안에 대하여 화재실험을 진행하였으며, 무 보강조건과 형상변화시에 발생하는 합성플로어의 처짐을 비교 분석하여 효과적인 단면형상 설계조건을 도출하고자 하였다. 실험결과 웨브 보강방안에 비해 하부플랜지 보강시 내화성능 향상효율이 더 높은 것으로 나타났으며, 이는 화재에 직접적으로 노출되는 하부플랜지 부분에 보강을 하는 것이 급격한 온도상승으로 인한 강도저하로 인해 발생하는 변형을 보다 효율적으로 제어하기 때문으로 판단된다.