• Title/Summary/Keyword: Cross Section Taper

Search Result 50, Processing Time 0.021 seconds

Vibration Transmission Characteristics due to the Variation in the Cross-section of a Waveguide (파동 유도 봉의 단면 변화에 따른 진동 전달 특성)

  • Kim, Dae-Seung;Kim, Jin-Oh
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.4 s.121
    • /
    • pp.310-316
    • /
    • 2007
  • This paper presents a theoretical approach to describe the characteristics of vibration transmission in the waveguide with varying cross-section. The waveguide considered in this paper has a tapered section in the middle of an axisymmetric stepped rod. The distributions of the vibration displacement and stress along the waveguide were derived and they were verified by comparing the theoretically-calculated results with those obtained by the finite-element analysis. The vibration magnification and the concentrated stress under forced vibration were calculated for this rod according to the taper length. The paper established a theoretical basement of designing waveguides for maximizing the vibration transmission under minimum stress concentration.

Free Vibration Analysis of Parabolic Hollowed Beam-columns with Constant Volume (일정체적을 갖는 포물선형 중공 보-기둥의 자유진동 해석)

  • Lee, Tae-Eun;Lee, Byoung-Koo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.384-391
    • /
    • 2011
  • This paper deals with free vibrations of the parabolic hollowed beam-columns with constant volume. The cross sections of beam-column taper are the hollowed regular polygons whose depths are varied with the parabolic functional fashion. Volumes of the objective beam-columns are always held constant regardless given geometrical conditions. Ordinary differential equation governing free vibrations of such beam-columns are derived and solved numerically for determining the natural frequencies. In the numerical examples, hinged-hinged, hinged-clamped and clamped-clamped end constraints are considered. As the numerical results, the relationships between non-dimensional frequency parameters and various beam-column parameters such as end constraints, side number, section ratio, thickness ratio and axial load are reported in tables and figures.

Ultimate load behaviour of tapered steel plate girders

  • Shanmugam, N.E.;Min, Hu
    • Steel and Composite Structures
    • /
    • v.7 no.6
    • /
    • pp.469-486
    • /
    • 2007
  • The paper is concerned with the behavior of tapered steel plate girders, primarily subjected to shear loading; experimental as well as finite element results obtained from the studies are presented in this paper. In the experimental study, 11 large-scale girders, one of uniform section and 10 tapered, were tested to failure and all girders were analysed by finite element method. The results are compared and the accuracy of the finite element modeling established. A parametric study was carried out with thickness of web, loading direction and taper angle as parameters. An analytical model, based on Cardiff model for girders of uniform cross-section, is also proposed in the paper.

Free Vibrations of Circular Curved Beams with Constant Volume (일정체적 원호형 곡선보의 자유진동)

  • Lee, Byoung-Koo;Lee, Tae-Eun;Choi, Jong-Min;Park, Chang-Eun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.6
    • /
    • pp.570-579
    • /
    • 2011
  • This paper deals with free vibrations of the circular curved beams with constant volume, whose cross sectional shapes are the circular solid cross-sections. Volumes of the objective beam are always held in constant regardless shape functions of the cross-sectional radius. The shape functions are chosen as the linear, parabolic and sinusoidal ones. Ordinary differential equations governing free vibrations of such beam are derived and solved numerically for determining the natural frequencies. In numerical examples, the hinged-hinged, hinged-clamped and clamped-clamped end constraints are considered. As the numerical results, relationships between frequency parameters and various beam parameters such as rise ratio, section ratio, elasticity ratio, volume ratio, slenderness ratio and taper type are reported in tables and figures.

The Evaluation in Displacement Response of Tapered Tall Buildings to Wind Load (풍하중을 받는 테이퍼 고층건물의 진동변위응답 평가)

  • Cho, Ji-Eun;You, Ki-Pyo;Kim, Jong-Soo;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.5 no.4 s.18
    • /
    • pp.101-108
    • /
    • 2005
  • The investigations for mitigating wind-induced excitations of tall buildings have been carried out. The aerodynamic modification of a building shape changing the cross-section with height through tapering, which alters the flow pattern around the building, could reduce wind induced excitations of tall buildings. The fart that a tapered tall building might spread the vortex-shedding over a broad range of frequencies makes more effective for reducing acrosswind responses has been established. In this paper, to investigate the tapering effect for reducing wind-induced responses of a tapered tall building, high-frequency force-balance test was conducted. The six types of building models which have different taper ratio of 2.5%, 5%, 7.5%, 10%, 15% and one basic building model of a square cross-section were tested under the two typical boundary layers representing suburban and urban flow environment. The effect of wind direction was also considered.

  • PDF

Construction of a Database for Wire Cutting Electrodischarge Conditions and Variable taper Wire-cut Machining. (와이어 컷 방전가공조건 데이터베이스 구축 및 상하이형상 가공)

  • 유우식;이규섭
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.59
    • /
    • pp.119-127
    • /
    • 2000
  • This paper describes the database for wire cutting electrodischarge conditions and variable taper wire-cut Machining. Electodischarge wire-cut machining is applicable to all materials that are fairly good electrical conductors, including metals, alloys, and most carbides. Thus it provides a relatively simple method for making holes of any desired cross section in materials that are too hard or brittle to be machined by most other methods. In conventional wire cutting CAM systems usually generate the NC code omitting electrodischarge conditions, so operator edits the NC code manually. But it is very inefficient. Therefore in this paper we propose a wire cutting CAM system including database for electrodischarge conditions. Proposed system consists of three steps: 1) Development of database for electrodischarge conditions 2) Development of CAM functions, Including 2D CAD modeling tools, file I/O functions, wire path genera tion functions and postprocessor. 3) Development of variable taper wire-cut machining module. The proposed system has been tested in the JinYoung precision Machine Co.,LTD. and found to be working satisfactorily.

  • PDF

Free Vibrations of Tapered Circular Arches with Constant Volume (일정체적 변단면 원호형 아치의 자유진동)

  • Lee, Byoung-Koo;Lee, Tae-Eun;Yoon, Hee-Min;Choi, Jong-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.2
    • /
    • pp.144-152
    • /
    • 2010
  • This paper deals with free vibrations of the tapered circular arches with constant volume, whose cross sectional shape is the solid regular polygon. Volumes of the objective arches are always held constant regardless shape functions of the cross-sectional depth. The shape functions are chosen as the linear, parabolic and sinusoidal ones. Ordinary differential equations governing free vibrations of such arches are derived and solved numerically for determining the natural frequencies. In the numerical examples, hinged-hinged, hinged-clamped and clamped-clamped end constraints are considered. As the numerical results, the relationships between non-dimensional frequency parameters and various arch parameters such as rise ratio, section ratio, side number, volume ratio and taper type are reported in tables and figures.

Finite element analysis of the fluid-structure interaction in a compliant vessel (유연 혈관에서 유체-고체 상호작용에 대한 유한요소 해석)

  • Shim, Eun-Bo;Ko, Hyung-Jong;Kamm, Roger D.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.591-596
    • /
    • 2000
  • Flow through compliant tubes with linear taper in wall thickness is numerically simulated by finite element analysis. Two models are examined: a planar two-dimensional channel, and an axisymmetric tube. For verification of the numerical method, flow through a compliant stenotic vessel is simulated and compared to existing experimental data. Computational results for an axisymmetric tube show that as cross-sectional area falls with a reduction in downstream pressure, flow rate increases and reaches a maximum when the speed index (mean velocity divided by wave speed) is near unity at the point of minimum cross-section area, indicative of wave speed flow limitation or "choking" (flow speed equals wave speed) in previous one-dimensional studies. For further reductions in downstream pressure, flow rate decreases. Cross-sectional narrowing is significant but localized. When the ratio of downstream-to-upstream wall thickness is ${\le}$ 2 the area throat is located near the downstream end; as wall taper is increased to ${\ge}$ 3 the constriction moves to the upstream end of the tube. In the planar two-dimensional channel, area reduction and flow limitation are also observed when outlet pressure is decreased. In contrast to the axisymmetric case, however, the elastic wall in the two-dimensional channel forms a smooth concave surface with the area throat located near the mid-point of the elastic wall. Though flow rate reaches a maximum and then falls, the flow does not appear to be choked.

  • PDF

Free Vibrations of Horizontally Curved Beams with Variable Cross Section (변다면 수평 곡선보의 자유진동에 관한 연구)

  • 이병구;박광규;모정만;이재만
    • Computational Structural Engineering
    • /
    • v.11 no.3
    • /
    • pp.155-164
    • /
    • 1998
  • 이 논문은 변단면을 고려한 수평 곡선보의 자유진동에 관한 연구이다. 진동시 곡선보 요소에 작용하는 합응력과 관성력의 동적평형방정식을 이용하여 변단면 원호형 수평 곡선보의 자유진동을 지배하는 상미분방정식을 유도하였다. 이 미분방정식을 원형 단면을 갖는 선형변변단면에 적용하여 고유진동수, 진동형 및 합응력을 산출하였다. 수치 해석예에서는 양단고정 및 양단회전 곡선보를 채택하였으며, 수치해석 결과로서 고유진동수와 단면비, 세장비 및 중심각 사이의 관계를 그림에 나타내었다. 또한 실험실 규모의 실험을 통하여 본 연구결과의 타당성을 보였다.

  • PDF

Dynamic Stability Analysis of Tapered Beck Columns (변단면 Beck 기둥의 동적안정 해석)

  • Lee Byoung-Koo;Lee Tae-Eun;Kang Hee-Jong;Kim Gwon-Sik
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.949-954
    • /
    • 2006
  • The purpose of this paper is to investigate the stability of tapered columns with clamped one end and carrying a tip mass of rotatory inertia with translational elastic support at the other end. The linearly tapered columns with the solid rectangular cross-section is adopted as the column taper. The differential equation governing free vibrations of such Beck columns is derived using the Bernoulli-Euler beam theory. Both the divergence and flutter critical loads are calculated from the load-frequency curves which are obtained by solving the differential equation. The critical loads are presented as functions of various non-dimensional system parameters: the taper type, the subtangential parameter, mass ratio and spring stiffness.

  • PDF