• Title/Summary/Keyword: Critical angle

Search Result 764, Processing Time 0.023 seconds

Spray Characteristics of Swirl-coaxial Injector According to the Recess Length and Injection Pressure Variation (리세스 길이 및 분사압력 변이에 따른 스월 동축형 인젝터의 분무특성)

  • Bae, Seong Hun;Kwon, Oh Chae;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.68-76
    • /
    • 2016
  • This research is carried out for the performance evaluation of the injector that is one of the critical components of bipropellant-rocket-engine. Spray characteristics are investigated in detail according to the recess length and injection pressure on the swirl-coaxial-injector using gaseous methane and liquid oxygen as propellants. A visualization is conducted by the Schlieren photography that is composed of a light source, concave mirrors, knife, and high-speed-camera. A hollow-cone-shape is identified in the liquid spray that is spread only by inner injector and the spray angle is decreased due to the diminution of swirl strength in accordance with the increase of the length of injector orifice. When the injector sprays the liquid through the inner injector with the aid of gas through the outer injector, the spray angle in external mixing region tends to increase with rise of the recess length, while in internal mixing region, it is decreased. It is also confirmed that the same tendency of the spray angle with recess length appears irrespective of the injection pressure of liquid spray.

Coupling effects of vortex-induced vibration for a square cylinder at various angles of attack

  • Zheng, Deqian;Ma, Wenyong;Zhang, Xiaobin;Chen, Wei;Wu, Junhao
    • Wind and Structures
    • /
    • v.34 no.5
    • /
    • pp.437-450
    • /
    • 2022
  • Vortex-induced vibration (VIV) is a significant concern when designing slender structures with square cross sections. VIV strongly depends on structural dynamics and flow states, which depend on the conditions of the approaching flow and shape of a structure. Therefore, the effects of the angle of attack on the coupling effects of VIV for a square cylinder are expected to be significant in practice. In this study, the aerodynamic forces for a fixed and elastically mounted square cylinder were measured using wind pressure tests. Aerodynamic forces on the stationary cylinder are firstly discussed by comparisons of variation of statistical aerodynamic force and wind pressure coefficient with wind angle of attack. The coupling effect between the aerodynamic forces and the motion of the oscillating square cylinder by VIV is subsequently investigated in detail at typical wind angels of attack with occurrence of three typical flow regimes, i.e., leading-edge separation, separation bubble (reattachment), and attached flow. The coupling effect are illustrated by discussing the onset of VIV, characteristics of aerodynamic forces during VIV, and interaction between motion and aerodynamic forces. The results demonstrate that flow states can be classified based on final separation points or the occurrence of reattachment. These states significantly influence coupling effects of the oscillating cylinder. Vibration enhances vortex shedding, which creates strong fluctuations in aerodynamic forces. However, differences in the lock-in range, aerodynamic force, and interaction process for angles of attack smaller and larger than the critical angle of attack revealed noteworthy characteristics in the VIV of a square cylinder.

Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study (토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험)

  • Dae-Gun, Kim;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.857-862
    • /
    • 2022
  • The purpose of this study was to evaluate a three-dimensional conformal radiotherapy (3D-CRT) treatment plan with regard to head tilting in whole-brain radiotherapy (WBRT) using TomoDirect (TD) mode in Tomotherapy. WBRT 3D-CRT by TD was compared for a total of five head tilt angles (-20°, -10°, 0°. +10° and +20°). The dose homogeneity index (HI) and prescription dose index (CI) were calculated to confirm the target coverage. The maximum and average doses for critical organs such as the lens, eyeball and parotid glands were calculated for different angles of head tilting. The HI and CI were closet to the result value of 1 at the head tilted angle +10° and +20°. At a head tilted angle of +10°, the dose to the lens and eyeballs decreased by about 74% and about 30%, when compared with the reference angle (0°), respectively. The results of this study suggest that a head angle of +10 with chin-up would save adequate target coverage and reduce exposure dose to the lens.

Mechanical properties of tailings with dipping interlayers under high confining pressure

  • Qinglin, Chen;Zugui, Li;Zeyu, Dai;Xiaojun, Wang;Chao, Zhang
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp.557-571
    • /
    • 2022
  • Landslides are often triggered by weak interlayers initiated in tailings dam foundations, and hazards gradually occur. This is serious for landslides in high tailings dams due to their high potential energy. Tailing samples with a fine-grained interlayer at a set dip angle were prepared. Consolidated undrained (CU) triaxial shear tests were carried out by using a high-pressure triaxial apparatus. The results were compared with the results under a low confining pressure. Four reasons were summarized for high tailings dams more prone to instability than low dams. The shear strength of the samples with dipping interlayers decreases with increasing dip angle. An obvious straight drop in the stress path after the peak occurs in samples with dipping interlayers at an angle of 60°. The effect of the interlayer on the mechanical behaviour of tailings is very sensitive, especially for the sample with a dipping interlayer at an angle of 60°. Shear slipping along the interlayer should be given more attention in tailings dams. Compared with the results under low confining pressure, the stress decreases continuously for the samples with dipping interlayers at large angles under high confining pressure. The positive pore pressure, which reduces the effective stress, occurred in tailings samples under high confining pressure. The residual strength of tailings under high confining pressure is smaller than that under low confining pressure. These factors increase the dam break risk and the disaster impact for high tailings dams.

Synthesis and Properties of Anionic Sulfonate Surfactants Using Fatty Alcohol (Fatty alcohol을 이용한 음이온 술폰산계 계면활성제의 합성 및 물성)

  • Cho, Jung-Eun;Shin, Hye-Lin;Jeong, Noh-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.579-586
    • /
    • 2018
  • In this study, surfactants were synthesized using fatty alcohols of 8, 10, 12 and 14 carbon chains length. The structures of the synthesized surfactants was confirmed by FT-IR and $^1H$-NMR analysis. The surface tension of the diluted surfactant was measured as 26~32 mN/m depending on the carbon length and the critical micelle concentration was measured as $10^{-3}{\sim}10^{-5}mol/L$.The minimum value per molecule of the synthesized sulfonic acid surfactant is 1.68 to $1.30nm^2$. The physical properties of the synthesized surfactants were determined by measuring the critical micelle concentration, foaming power, emulsifying stability, and contact angle.

Quantitative Analysis of Phosphors Decay Characteristic for Flicker-free Display System Design (플리커 저감 디스플레이 시스템 설계를 위한 인광체 잔광 특성의 정량적 해석)

  • Kwon, Yong-Dae;Choi, Duk-Kyu;Han, Chan-Ho;Lee, Gwang-Soon;Kim, Eun-Su;Lee, Sang-Hoon;Sohng, Kyu-Ik
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.6
    • /
    • pp.9-16
    • /
    • 2000
  • The perception of flicker on the computer display devices depends upon the temporal waveform of the phosphor decay characteristic, the frame rate, and the display size. The lowest frequency at which flicker is not perceived is called the critical fusion frequency or critical frequency. Critical fusion frequency is evaluated by the display illuminance and the modulation (m) defined as the ratio of the amplitude of first harmonic frequency to the DC of the waveform. In this paper, we analyze the relationship bet ween the critical fusion frequency, relating to the decay characteristic of the phosphors and luminance on the monitor, and the frame frequency. Also under considering the viewing angle, we presented the frame frequency that is less sensitive to the full size of the display device.

  • PDF

Dynamic Fracture Properties of Nylon Thermoplastic Material Depending on Notch Angle with Charpy Impact Machine and Finite Element Method (유한요소법과 샤피충격시험기에 의한 노치각도에 따른 나일론 열가소성 플라스틱 재료의 파괴특성)

  • Park, Myung-Kyun;Lee, Jung-Won;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • The notched Charpy impact test is one of the most prevalent techniques used to characterize the effect of high impulse loads on polymeric materials. In this study, a method of analysis in nylon plastic materials is suggested to evaluate the critical strain energy release rate for variation of notch angles from the Charpy impact energy measurement. Instrumented Charpy impact tester was used to extract ancillary information concerning fracture parameters in addition to total fracture properties and maximum critical load. The dynamic stress intensity factor of nylon plastic material was calculated for the ASTM Charpy specimen from the obtained maximum critical load. Also, the finite element model was developed to figure out the stress distributions for Charpy specimen with different notch angles subject to 3 point bending load which is equivalent to the load applied in the experiment.

  • PDF

Analysis of Behaviour of Prey to avoid Pursuit using Quick Rotation (급회전을 이용한 희생자의 추격 피하기 행동 분석)

  • Lee, Jae Moon
    • Journal of Korea Game Society
    • /
    • v.13 no.6
    • /
    • pp.27-34
    • /
    • 2013
  • This paper analyzes the behaviour of a prey to avoid the pursuit of a predator at predator-prey relationship to be appeared in the collective behavior of animals. One of the methods to avoid the pursuit of a predator is to rotate quickly when a predator arrives near to it. At that moment, a critical distance and a rotating angular are very important for the prey in order to survive from the pursuit, where the critical distance is the distance between the predator and the prey just before rotation. In order to analyze the critical distance and the rotating angular, this paper introduces the energy for a predator which it has at starting point of the chase and consumes during the chase. Through simulations, we can know that the rotating angle for a prey to survive from the pursuit is increased when the critical distance is shorter and when the ratio of predator's mass and prey's mass is also decreased. The results of simulations are the similar phenomenon in nature and therefore it means that the method to analyze in this paper is correct.

Tracheal pleomorphic adenoma with coexisting pulmonary tuberculoma

  • Kim, Jehun;Oak, Chul-Ho;Jang, Tae-Won;Jung, Mann-Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.1
    • /
    • pp.114-120
    • /
    • 2018
  • Tracheal tumors are rare and difficult to diagnose. Moreover, delays in diagnosis are very common because the symptoms are nonspecific. As a result, tracheal tumors are commonly mistreated as chronic obstructive pulmonary disease or bronchial asthma. We report a case of a 49-year-old male who presented with a 3-month history of dyspnea and cough. Chest computed tomography scan showed a $1.5{\times}1.3cm$ homogenous tumor originating from the right lateral wall of the tracheobronchial angle into the tracheal lumen as well as a $0.5{\times}0.4cm$ round nodular lesion at the right upper lobe with multiple mediastinal lymph nodes enlargement. Bronchoscopic findings revealed a broad-based, polypoid lesion nearly obstructing the airway of the right main bronchus. The patient was diagnosed with pleomorphic adenoma which is the most common benign tumor of the salivary glands, but rarely appears in the trachea. Upon surgery, tracheal pleomorphic adenoma and co-existing active pulmonary tuberculoma that had been mistreated as bronchial asthma over 3 months was revealed. Following surgery, the patient underwent anti-tuberculosis treatment. No recurrence has been detected in the 3 years since treatment and the patient is now asymptomatic.

Numerical Simulation of Cone Penetration Tests in Sand Ground Using Critical State Mohr Coulomb Plasticity Model (한계상태 Mohr Coulomb 소성 모델을 활용한 콘관입시험의 수치적 모사)

  • Woo, Sang Inn;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.2
    • /
    • pp.37-51
    • /
    • 2019
  • This study focuses on the numerical simulations of the cone penetration tests in a sand ground. The mechanical responses of sand were described using the modified Mohr Coulomb plasticity model based on the critical state soil mechanics. In the plasticity model, the dilatancy angle was not a constant, but a function of the distance to the critical state line from the current state of void ratio and mean effective stress. To simulate cone penetration tests numerically, this study relied on Lagrangian finite element method under the axisymmetric condition. To enable penetration of the cone penetrometer without tearing elements along the symmetric axis, the penetration guide concept was adopted in this study. The results of numerical simulations on the calibration chamber cone penetration tests had good agreement with the experimental results.