• Title/Summary/Keyword: CrN film

Search Result 143, Processing Time 0.036 seconds

Analysis of Electronic Materials Using Transmission Electron Microscopy (TEM) (전자현미경을 이용한 전자재료분석)

  • Kim, Ki-Bum
    • Applied Microscopy
    • /
    • v.24 no.4
    • /
    • pp.132-144
    • /
    • 1994
  • The application of TEM in investigating the evolution of microstructure during solid phase crystallization of the amorphous Si, $Si_{1-x}Ge_x,\;and\;Si_{1-x}Ge_x/Si$ films deposited on $SiO_2$ substrate, in identifying the failure mechanism of the TiN barrier layer in the Cu-metallization scheme, and in comparing the microstructure of the as-deposited Cu-Cr and Cu-Ti alloy films are discussed. First, it is identified that the evolution of microstructure in Si and $Si_{1-x}Ge_x$ alloy films strongly depends on the concentration of Ge in the film. Second, the failure mechanism of the TiN diffusion barrier in the Cu-metallization is the migration of the Cu into the Si substrate, which results in the formation of a dislocation along the Si {111} plane and precipitates (presumably $Cu_{3}Si$) around the dislocation. Finally, the microstructure of the as-deposited Cu-Cr and Cu-Ti alloy films is also quite different in these two cases. From these several cases, we demonstrate that the information which we obtained using TEM is critical in understanding the behavior of materials.

  • PDF

Effect of Negative Substrate Bias Voltage on the Microstructure and Mechanical Properties of Nanostructured Ti-Al-N-O Coatings Prepared by Cathodic Arc Evaporation

  • Heo, Sungbo;Kim, Wang Ryeol;Park, In-Wook
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.3
    • /
    • pp.133-138
    • /
    • 2021
  • Ternary Ti-X-N coatings, where X = Al, Si, Cr, O, etc., have been widely used for machining tools and cutting tools such as inserts, end-mills, and etc. Ti-Al-N-O coatings were deposited onto silicon wafer and WC-Co substrates by a cathodic arc evaporation (CAE) technique at various negative substrate bias voltages. In this study, the influence of substrate bias voltages during deposition on the microstructure and mechanical properties of Ti-Al-N-O coatings were systematically investigated to optimize the CAE deposition condition. Based on results from various analyses, the Ti-Al-N-O coatings prepared at substrate bias voltage of -80 V in the process exhibited excellent mechanical properties with a higher compressive residual stress. The Ti-Al-N-O (-80 V) coating exhibited the highest hardness around 30 GPa and elastic modulus around 303 GPa. The improvement of mechanical properties with optimized bias voltage of -80 V can be explained with the diminution of macroparticles, film densification and residual stress induced by ion bombardment effect. However, the increasing bias voltage above -80 V caused reduction in film deposition rate in the Ti-Al-N-O coatings due to re-sputtering and ion bombardment phenomenon.

Characteristic of PECVD-$WN_x$ Thin Films Deposited on $Si_3N_4$ Substrate ($Si_3N_4$ 기판 위에 PECVD 법으로 형성한 Tungsten Nitride 박막의 특성)

  • Bae, Seong-Chan;Park, Byung-Nam;Son, Seung-Hyun;Lee, Jong-Hyun;Choi, Sie-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.17-25
    • /
    • 1999
  • Tungsten nitride($WN_x$) films were deposited by PECVD method on silicon nitride($WSi_3N_4$) substrate. The characteristics of $WN_x$ film were investigated with changing various processing parameters ; substrate temperature, gas flow rate, rf power, and different nitrogen sources. The nitrogen composition in $WN_x$ film varied from 0 to 45% according to the $NH_3$ and $N_2$ flow rate. The highest deposition rate of 160 nm/min was obtained for the $NH_3$ gas and relatively low deposition rate of $WN_x$ films were formed by $N_2$ gas. $WN_x$ films deposited on $WSi_3N_4$ substrate had higher deposition rate than that of TiN and Si substrates. The purity of $WN_x$ film were analyzed by AES and higher purity $WN_x$ films were deposited using $NH_3$ gas. The XRD analysis indicates a phase transition from polycrystalline tungsten(W) to amorphous tungsten nitride($WN_x$), showing improved etching profile of $WN_x$ films Thick $WN_x$ films were deposited on various substrates such as Tin, NiCr and Al and maximum thickness of $1.6 {\mu}m$ was obtained on the Al adhesion layer.

  • PDF

Groundwater Quality in the Shallow Aquifer at the Plastic Film Houses Area near Livestock Area in Kyongan River Basin (경안천유역내 축산단지 인근 시설원예지역의 천층지하수 수질특성)

  • 김진호;문광현;안승구
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.77-85
    • /
    • 2001
  • This study was carried out to show the groundwater quality in the shallow aquifer at the plastic film houses area near livestock areas in Kyong=n river. The study was conducted at 31 sites in Pogok Myon. Yongin City, Kyonggi Province on March, June and August in 1998, Medium value of CO $D_{cr}$ by survey months was as follows ; June(8.0mg/L) > April(4.4mg/L) > August(3.2mg/L). And the value of $NH_3$-N showed same tendency ; June (0.21mg/L) > April(0.08mg/L) > August (0.04mg/L). In case of nitrate- nitrogen, the changes by survey months were shown similar. But 28% of survey sites exceeded to agricultural groundwater quality reference level(20mg/L). And sulfur concentrations at some survey sites exceeded the reference level(50mg/L). But the other items of water quality were shown to suitable level for agriculture. The result showed that groundwater quality management should be taken for agricultural using at the livestock and plastic film house areas.

  • PDF

인공관절의 수명 향상을 위해 PIII&D (Plasma Immersion Ion Implantation & Deposition) 기술로 제조된 인공관절용 NbN 박막의 마모 특성 평가

  • Park, Won-Ung;Jeon, Jun-Hong;Mun, Seon-U;Choe, Jin-Yeong;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.189-189
    • /
    • 2011
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 관절 운동을 하는 라이너(Liner)와 헤드(Head) 부분이 인공관절의 수명을 결정하게 되는데, 헤드 부분에 메탈소재와 라이너 부분에 고분자 소재를 사용하는 MOP (metal on polymer) 구조의 인공관절은 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인하여 관절이 느슨해지는 문제점이 발생하여 재 시술의 주요 원인이 되고 있다. 또한 메탈 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 낮추는 또 하나의 요인이 되고 있다. 따라서 인공관절의 수명을 늘리기 위해 DLC, ZrO, TiN 등의 높은 경도 값을 갖는 박막을 금속 헤드 위에 증착하여 상대재인 인공관절용 고분자 소재의 마모량을 줄이고자 하는 연구가 활발하게 진행 되고 있다. 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition)공정을 이용하여 Co-Cr-Mo 합금 소재 niobium nitride (NbN) 박막을 증착하여 상대제인 UHMWPE (ultra high molecular polyethylene)의 마모를 줄이고자 하는 연구를 진행하였다. 마모량을 감소시키기 위하여, 박막 증착전에 질소를 이온주입하는 pre-ion implantation 공정을 도입하였으며, 또한 Co-Cr 합금과 NbN박막 사이의 접착력을 증가시키기 위하여 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. NbN 박막의 특성을 평가하기 위해 XRD, XPS, AFM 등의 분석을 수행하였으며, 상대재인 초고분자량 폴리에틸렌의 마모량을 측정하기 위해 Pin-on-disk tester를 이용하여 마모 실험을 진행하였다. 마모 실험 결과, pre-ion implantation 공정을 도입한 경우 현재 상용화 되어있는 Co-Cr 합금에 비하여 마모량을 2배 이상 감소시키는 것을 확인 할 수 있었으며, dynamic ion mixing 공정을 도입한 경우 장시간의 마모 시험에 대한 마모 특성이 향상 되는 것을 확인 할 수 있었다.

  • PDF

A Study on Improvement of Material Characteristics by Control of Ion Implantation (이온주입 제어에 의한 재료특성 개선에 관한 연구)

  • Yang, Young-Joon;Lee, Chi-Woo;Fujita, Kazuhisa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1178-1184
    • /
    • 2008
  • In this study, techniques of ion implantation were used in order to improve the characteristics of metal materials such as the oxidation and wear resistant. In particular it is necessary to develope their oxidation and wear resistant that could be used in severe environmental conditions. There are mainly two elementary technologies including ion implantation and/or thin film coating. Ion implantation method was performed for surface modification. As a result, it was found that some ion implantations methods such as Nb, high-temperature Nb ion implantation and Nb+C combined implantation are somewhat effective for improving the oxidation resistance of TiAl alloy. Furthermore, the fluorine PBII treatment is more effective for improving the oxidation resistance of the TiAl alloy with three-dimensional shapes. The implantation of boron ion into thin film of TiN was also effective for improving the properties of materials like high temperature wear resistance. TiCrN film was applied to the actual seal ring for steam turbines, and it was observed that its sliding property showed a successfully good performance.

Corrosion Behaviors of TiN Coated Dental Casting Alloys (TiN피막 코팅된 치과주조용 합금의 부식거동)

  • Jo, Ho-Hyeong;Park, Geun-Hyeng;Kim, Won-Gi;Choe, Han-Cheol
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.2
    • /
    • pp.129-137
    • /
    • 2009
  • Corrosion behaviors of TiN coated dental casting alloys have been researched by using various electrochemical methods. Three casting alloys (Alloy 1: 63Co-27Cr-5.5Mo, Alloy 2: 63Ni-16Cr-5Mo, Alloy 3: 63Co-30Cr-5Mo) were prepared for fabricating partial denture frameworks with various casting methods; centrifugal casting(CF), high frequency induction casting(HFI) and vacuum pressure casting(VP). The specimens were coated with TiN film by RF-magnetron sputtering method. The corrosion behaviors were investigated using potentiostat (EG&G Co, 263A. USA) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion morphologies were analyzed using FE-SEM and EDX. Alloy 1 and Alloy 2 showed the ${\alpha}-Co$ and ${\varepsilon}-Co$ phase on the matrix, and it was disappeared in case of TiN coated Alloy 1 and 2. In the Alloy 3, $Ni_2Cr$ second phases were appeared at matrix. Corrosion potentials of TiN coated alloy were higher than that of non-coated alloy, but current density at passive region of TiN coated alloy was lower than that of non-coated alloy. Pitting corrosion resistances were increased in the order of centrifugal casting, high frequency induction casting and vacuum pressure casting method from cyclic potentiodynamic polarization test.

Thick Film Resistance Paste for Improving Reliability and TCR Properties of Embedded Resistor Board (내장형 저항 기판의 신뢰성과 TCR 개선을 위한 후막 저항 페이스트에 관한 연구)

  • Lee, S.M.;Yoo, M.J.;Park, S.D.;Kang, N.K.;Nam, S.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 2008
  • Due to the increasing need for miniaturization of electronic device, embedded resistor technology using thick film resistance paste to embed resistors currently mounted on the board thus effectively reducing board size, is being extensively researched. In this research, thick film resistor paste having $0.35{\sim}4k{\Omega}/sq$ range of resistivity were fabricated using mixtures of carbon black and epoxy resin. In order to adjust the TCR (temperature coefficient resistivity), TCR modifiers such as Ni-Cr alloy, $SiO_2$ powder were added and were able to improve on TCR value with $100ppm/^{\circ}C$. Finally embedded resistor board using thick film resistance paste were fabricated. Stable resistivity value and reliability results were achieved.

  • PDF

Some French and German Movies for the Multi-cultural Education at Schools (학교에서의 다문화교육을 위한 프랑스와 독일의 영화)

  • HAN, Yong-taek
    • Cross-Cultural Studies
    • /
    • v.19
    • /
    • pp.205-232
    • /
    • 2010
  • The purpose of this paper is to examine the possibility of application of some French and German movies to teaching of multi-culture in elementary, middle and high schools. Three different films are selected. (2005), a French animation film directed by B?n?dicte Galup and Michel Ocelot, is appropriate for the education of understanding cultural relativity and improving multi-cultural sensitivity in elementary school. is a French short film directed by Walter Salles and Daniela Thomaso and included in omnibus style film (2006). This short film relating a story of an immigrated woman who leaves her baby in a cr?che and travels through Paris to work for a bourgeois mother can be used for developing a bond of sympathy between natives and immigrants. It is recommended for the class of junior high school. Finally (2007), a German film directed by Fatih Akin, provide a learning model for the education of multi-culture in high school classrooms. The cinematographic aesthetic of this film is focused on a process of reconciliation with others over the cultural, racial, national and generational differences. Analyzing the structure of the film and being guided by teachers the students can understand better in improving abilities to understand others.

Fabrication of 2-layer Flexible Copper Clad Laminate by Vacuum Web Coater with a Low Energy Ion Source for Surface Modification (저 에너지 표면 개질 이온원이 설치된 진공 웹 공정을 이용한 2층 flexible copper clad laminate 제작)

  • Choi, Hyoung-Wook;Park, Dong-Hee;Choi, Won-Kook
    • Korean Journal of Materials Research
    • /
    • v.17 no.10
    • /
    • pp.509-515
    • /
    • 2007
  • In order to fabricate adhesiveless 2-layer flexible copper clad laminate (FCCL) used for COF (chip on film) with high peel strength, polyimide (PI; Kapton-EN, $38\;{\mu}m$) surface was modified by reactive $O_2^+$ and $N_2O^+$ ion beam irradiation. 300 mm-long linear electron-Hall drift ion source was used for ion irradiation with ion current density (J) higher than $0.5\;mA/cm^2$ and energy lower than 200 eV. By vacuum web coating process, PI surface was modified by linear ion source and then 10-20 nm thick Ni-Cr and 200 nm thick Cu film were in-situ sputtered as a tie layer and seed layer, respectively. Above this sputtered layer, another $8-9{\mu}m$ thick Cu layer was grown by electroplating and subsequently acid and base resistance and thermal stability were tested for examining the change of peel strength. Peel strength for the FCCLs treated by both $O_2^+$ and $N_2O^+$ ion irradiation showed similar magnitudes and increased as the thickness of tie layer increased. FCCL with Cu (200 nm)/Ni-Cr (20 nm)/PI structure irradiated with $N_2O^+$ at $1{\times}10^{16}/cm^2$ ion fluence was proved to have a strong peel strength of 0.73 kgf/cm for as-received and 0.34 kgf/cm after thermal test.