• Title/Summary/Keyword: Coverage index

Search Result 288, Processing Time 0.033 seconds

Coverage, Density and Completeness of Sources used in Tehran Metropolitan Area Cancer Registry: According to the Data of Esophageal Cancer, 2003-2007

  • Aghaei, Abbas;Najafi, Farid;Mosavi-Jarrahi, Alireza;Ahmadi-Jouibari, Toraj
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3617-3619
    • /
    • 2012
  • Background: The completeness of cancer registration is a major validity index of any reported cancer incidence. The present study aimed to evaluate the esophageal cancer incidence registered in the Tehran Metropolitan Area Cancer Registry. Materials and methods: The data on esophageal cancer abstracted from three sources of 1) pathology departments, 2) medical records, and 3) death certificates during 2003 till 2007 were utilized. The completeness of the data sources were evaluated using coverage (defined as the proportion of a community population with esophageal cancer identified by the source) and density (defined as the proportion of non-empty fields of the data by source). Results: A total 1,404 cases of esophageal cancer were reported for the duration of the study. Pathology provided 771, medical records 432, and death certificates 609. The coverage was 0.55 for pathology, 0.31 for medical records, and 0.43 for death certificates. The respective density values were 0.82, 0.96 and 0.98, respectively. Pathology (0.45) was the most complete source followed by medical records (0.42), and death certificates (0.29). Discussion: A low degree of completeness dictates putting more effort into case finding plus abstracting data more thoroughly.

Analysis of patterned ITO layer of PDP thin films using spectroscopic ellipsometry (분광타원법을 이용한 PDP용 ITO 박막의 패턴 분석)

  • 윤희삼;김상열
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.272-278
    • /
    • 2003
  • We studied patterned ITO layers of PDP thin films on glass substrates using spectroscopic ellipsometry. The optical property of ITO is expressed with the optical model based on two Lorentz oscillators. The effect of patterned ITO is calculated by taking the weighted average of reflectance in proportion to ITO coverage. The relative coverage of ITO is determined by using the model analysis of spectroellipsometric data. The difference of ITO coverage obtained by the best-fit model analysis of ellipsometric spectra to the expected one is critically examined and suggestions are made to minimize the observed discrepancy.

Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Purpose: To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. Materials and Methods: Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. Results: The median level I and II axillary volume coverage percentages at the $V_{D95%}$ line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. Conclusion: The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

F-GAMMA with KVN

  • Park, Songyoun;Sohn, Bong Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.42.2-42.2
    • /
    • 2013
  • The F-GAMMA (FERMI-GST AGN Multi-frequency Monitoring Alliance) project is a program for the monthly monitoring of the broad-band spectra of currently about 90 selected Fermi-GST AGNs. F-GAMMA utilizes several facilities in cm, mm, sub-mm, infrared and optical bands, achieving an unprecedented coverage for the study of the spectral evolution of powerful relativistic jets in AGNs. The KVN joined the F-GAMMA project in May 2011, aiming to monitor flux density at 22 and 43 GHz. We present the preliminary results of flux density variability, evolution of spectral index, and modulation index.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

The Usability Evaluation Half Beam Radiation Treatment Technique on the Esophageal Cancer (식도암 환자에서의 Half Beam 치료법의 유용성 평가)

  • Park, Hochoon;Kim, Youngjae;Jang, Seongjoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.287-293
    • /
    • 2015
  • Because of esophageal cancer has the long length of the lesion and also inhomogeneous in depth. So, the radiation dose distribution was inhomogeneous in radiation therapy. To overcomes the dose distribution uniformity using half beam method. Patient's CT image was used radiation treatment planning. We used two planning methods that one is the using normal beam and another is using half beam. Than comparing the two radiotherapy planning using target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues - heart, spinal cord, lung -. In results, Treatment planning using half beam is little more than normal beam in target coverage, dose volume histogram, conformity index, homogeneity index and normal tissues covering. However, If the patient is not correct position patients may arise a side effect. Thus, the using in Half beam involving the geometrically exact under lung cancer is considered to advantage.

Dynamics of Marine Benthic Community in Intertidal Zone of Seoam, Busan (부산 서암 조간대 부착생물군집의 동태)

  • 유종수
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.8 no.4
    • /
    • pp.420-425
    • /
    • 2003
  • Species composition, community structure and biodiversity of marine benthic community were studied in the intertidal zone of Seoam, Busan. A total of 75 species of benthic marine plants including 4 Cyanophyta, 6 Chlorophyta, 17 Phaeophyta, 47 Rhodophyta and 1 Magnoliophyta are listed. The dominant marine plants were melobesioidean algae, Chondracanthus tenellus, Sargasium thunbergii, Corallina spp., and Phyllospadix japonica and Ulva pertusa was added in summer. Chthamalus challengeri and Mytilus edulis were dominant zoobenthic species in the upper and middle intertidal zone. The algal species diversity index based on coverage was 1.81; 2.25 from frequency; 2.19 from average of total frequency and coverage, and 1.80 from importance value. The algal diversity indices estimated from different sources were quite different. This means that the index value changes depending on the sources used to calculate the species diversity index, indicating how important it is to select the based data and that it is necessary to standardize the methodology when studying later the algal diversity index. On the other hand, the number of species identified in this study has been found to be reduced by 65% at highest, compared with the result of the investigation that was conducted in the coast of Busan.

Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study (토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험)

  • Dae-Gun, Kim;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.857-862
    • /
    • 2022
  • The purpose of this study was to evaluate a three-dimensional conformal radiotherapy (3D-CRT) treatment plan with regard to head tilting in whole-brain radiotherapy (WBRT) using TomoDirect (TD) mode in Tomotherapy. WBRT 3D-CRT by TD was compared for a total of five head tilt angles (-20°, -10°, 0°. +10° and +20°). The dose homogeneity index (HI) and prescription dose index (CI) were calculated to confirm the target coverage. The maximum and average doses for critical organs such as the lens, eyeball and parotid glands were calculated for different angles of head tilting. The HI and CI were closet to the result value of 1 at the head tilted angle +10° and +20°. At a head tilted angle of +10°, the dose to the lens and eyeballs decreased by about 74% and about 30%, when compared with the reference angle (0°), respectively. The results of this study suggest that a head angle of +10 with chin-up would save adequate target coverage and reduce exposure dose to the lens.

Clinical Experience of Pulmonary Embolism after Coverage of Pressure Sore (압박 궤양 수술 후 발생된 페색전증 치험례)

  • Seo, Sang Woo;Lee, Won Jai;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.543-546
    • /
    • 2005
  • Pulmonary embolism is a one of the major cause of postoperative death. Surgery predisposes patients to pulmonary embolism, even as late as one month after the operation. The accurate detection of pulmonary embolism remains difficult, and the differential diagnosis is extensive. The prevention of pulmonary embolism is thus of paramount importance. We report a case of pulmonary embolism after coverage of pressure sore on the left ischium on the 8th day after operation. The patient was 60 years old, a severe smoker, in the high quantity of body mass index and had hypertension. The risk factors are 60 years of age or older who were in the highest quantity of body mass index. Heavy cigarette smoking and high blood pressure are also identified as risk factors. Plastic surgeons should keep the probability of pulmonary embolism development after operation in mind. When taking history, the risk factors should be checked certainly. The immobilization may explain the probability of pulmonary embolism development. Therefore absolute bed rest or positional maintenance should be avoided. Until recently, low molecular weight heparin has been used for preoperative prophylaxis. Plastic surgeons should be concerned in low molecular weight heparin for prophylaxis of the pulmonary embolism and study the indications and effectiveness in liposuction or abdominoplasty.

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • Progress in Medical Physics
    • /
    • v.31 no.4
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.