• Title/Summary/Keyword: Cover Song

Search Result 353, Processing Time 0.027 seconds

Application of Continuous Fiber Soil Reinforcement System in Riparian Slopes (연속섬유보강토공법의 하천구역 적용사례에 관한 연구)

  • Koh, Jeung-Hyun;Hur, Young-Jin;Choi, Jaeyong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.14 no.3
    • /
    • pp.169-176
    • /
    • 2011
  • The purpose of this study is to examine the ecologically suitable restoration characteristics in riparian slopes constructed by continuous fiber soil reinforced system (Geofiber system) which does not contain the concrete materials. The findings are as follows : (1) as the tested soil was not washed away by rainfalls and floods, Geofiber could replace the concrete wall and gravity stone net bag technique from the civil engineering structural point of view; (2) after one year of the construction, it was monitored that land cover ratio was 80-90%, which indirectly shows that vegetation is safely maintained; and (3) at the same time, 5-8 flora species were found in each test grid and more importantly dominant species have been moved from alien species to native herbaceous plants. From the above findings, Geofiber system is recommendable to restore the riparian slopes in terms of stability and natural landscape points. However, a long term monitering is needed considering flora succession process in a given environment as well as suitability tests should be carried out through the comparative investigations in other environments.

Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact- (800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석-)

  • Shin, Y.J.;Park, K.Y.;Chang, K.C.;Song, K.D.;Jeong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF

INJECTIVE COVERS OVER COMMUTATIVE NOETHERIAN RINGS OF GLOBAL DIMENSION AT MOST TWO II

  • KIM, HAE-SIK;SONG, YEONG-MOO
    • Communications of the Korean Mathematical Society
    • /
    • v.20 no.3
    • /
    • pp.437-442
    • /
    • 2005
  • In studying injective covers, the modules C such that Hom(E, C) = 0 and $Ext^1$(E, C) = 0 for all injective module E play an important role because of Wakamatsu's lemma. If C is a module over the ring k[[x, y]] with k a field, the class of these modules C contains the class $\={D}$ of all direct summands of products of modules of finite length ([3, Theorem 2.9]). In this paper we show that every module over any commutative ring has a $\={D}$-preenvelope.

Vegetation changes and their causes in andong dam areas (安東댐 建設에 의한 植生變化와 그 要因)

  • Song, Jong--Suk
    • The Korean Journal of Ecology
    • /
    • v.15 no.4
    • /
    • pp.411-431
    • /
    • 1992
  • The present study was undertaken to classify and describe the vegetation around andong dam area, kyong-buk, korea$(36^{\circ}\;35^{\prime}\;N, \;128^{\circ}\;47^{\prime}\;E)$ by methods of the ZM school of phytosociology. The investigations were carried out in the plot. The homogeneous part of forest and grass communities was analyzed by recording the combined scale of cover-abundance and sociability of all species found in the plot. The community data obtained were classified into two associations and seven communities; festuco onvinae-pinetum densiflorae assoc. nov., quercetum variabili-serratae, quercus acutissima community, larix leptolepis, populus tomentiglandulosa, acer canadensis, prunus spp. afforestations, robinia pseudo-acacia-commelina communis community and acer palmatum cv. afforestation. The grass vegetation was divided into six associations and seventeen communities; lactuco indicae- humuletum japonicae, eragrostio ferruginei-plantaginetum asiaticae, polygonetum thunbergii, phragmitetum japonicae, eragrostio ferruginei-plantaginetum asiaticae, polygonetum thunbergii, phragmitetum japonicae, artemisio-potentilletum chinesis, eleusinetum indicae, amorpha freticosa, artemisia princeps, achyranthes fauriei and other fourteen communities. amoung the above vegetationship of the vegetation units with their environments was outlined.

  • PDF

An Empirical Study on the Operation of Quality Management (강원도 중소기업의 품질경영 운영에 관한 실증적 연구)

  • Park Roh Gook;Lee Song Ho
    • Journal of Korean Society for Quality Management
    • /
    • v.32 no.4
    • /
    • pp.274-285
    • /
    • 2004
  • This study, in particular, studied the consortium-participating companies on their plans of Quality Management as to how they carry them out in order to advance to the first-class business enterprises. These companies' present status and activities under implementation identified and interpreted by this study, therefore, are insufficient to be generalized into knowledge applicable to most of the companies in Gangwon-do. For more precise and detailed results, it is suggested to make further studies that cover not only those consortium companies but also non-consortium manufacturing companies if Gangwon-do.

A case Report of Splenic Abscess (비장농양 치험 1예)

  • Shim, Min-Chul;Song, Sun-Kyo;Kim, Hong-Jin;Kwun, Koing-Bo
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.339-342
    • /
    • 1986
  • Splenic abscess is an uncommon lesion and may be present either as a localized area of infection in the spleen or as a part of generalized sepsis. The diagnosis is difficult because of the rather nonspecific clinical picture. Hence, splenic abscess has a high mortality rate and is after diagnosed only at autopsy. Computerized tomography(CT) offers the clinician a reliable tool for the diagnosis of intra-abdominal abscess. A successful outcome is dependent on an early diagnosis and prompt treatment by splenectomy with antibiotic cover. We experienced a care of splenic abscess which was diagnosed by CT and treated by splenectomy with antibiotics. Postoperative course was relatively uneventful.

  • PDF

Fire Resistance Performance of High Strength-Light Weight Concrete (고강도를 적용한 1종 경량골재 콘크리트의 내화특성)

  • Song, Hun;Lee, Jong-Chan;Lee, Sea-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.749-752
    • /
    • 2005
  • Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Thus, this study is concerned with experimentally investigating fire resistance of high strength-light weight concrete. From the test result, high strength-light weight concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

  • PDF

Explosive Spalling of Structural Lightweight Aggregate Concrete (구조용 경량골재 콘크리트의 폭렬특성)

  • Song, Hun;Lee, Jong-Chan;Lee, Sea-Hyun;Kim, Woo-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.477-480
    • /
    • 2006
  • Normally, with all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Especially, high strength concrete and lightweight aggregate concrete is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with explosive spalling of lightweight concrete using structural lightweight aggregate. From the experimental test result, lightweight aggregate concrete is happened explosive spalling. The decrease of cross section caused by explosive spalling made sharp increasing gradient of inner temperature.

  • PDF

Effect of Carbonation Threshold Depth on the Initiation Time of Corrosion at the Concrete Durability Design (콘크리트의 내구성 설계시 탄산화 임계깊이가 철근부식 개시시기에 미치는 영향에 관한 연구)

  • Yang, Jae-Won;Lee, Sang-Hyun;Song, Hun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.229-230
    • /
    • 2010
  • The Carbonation, one of the main deterioration factors of concrete, reduces capacity of members with providing rebar corrosion environment. Consequently it suggested standards of all countries of world, carbonation depth prediction equation of respective researchers and time to rebar corrosion initiation. As a result of carbonation depth prediction equation calculation, difference of time to rebar corrosion initiation is 149 years and difference of carbonation depth prediction equation is 162 years when water cement ratio is 50%. So a study on rebar corrosion with carbonation depth will need existing reliable data and verifications by experiment.

  • PDF

A Comparative Study on Productivity of the Single PPM Quality Certification Company by using the Bootstrapped Malmquist Productivity Indices (부트스트랩 맘퀴스트 생산성지수를 이용한 Single PPM 인증기업의 생산성 비교 연구)

  • Song, Gwang-Seok;Yoo, Han-Joo
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2010.04a
    • /
    • pp.33-48
    • /
    • 2010
  • The purpose of this study is to empirically analyze the productivity change of the 10 Single PPM Certification Company in the 3 Industry(Electronics, Motor-Parts, Machines). In this study, Productivity change over the time in Korean small and medium sized firms in the 3 industries by the bootstrapped Malmquist Productivity Index(MPI). The traditional Malmquist Productivity Index(MPI) and Data Envelopment they could lead to wrong evaluations of the efficiency and productivity scores. In this paper, DEA and a MPI are combined with a bootstrap method in order to provide statistical inferences that analyze the performance of the Single PPM Certification Company. The data cover the period between 2004 and 2007. The result of this paper reveals : 1) The electronic industries(Motor-Parts, Machines). 2) average productivity Progress of the 7DMU(Electronics), 1DMU(Motor-Parts) and none(Machines).

  • PDF