• Title/Summary/Keyword: Coupled Line

Search Result 723, Processing Time 0.029 seconds

Performance Characteristics of an Inductively Coupled Magnetic Probe Developed for Off-line Monitoring of a Rotating Machine (발전기 정지중 진단을 위하여 개발된 유도결합 마그네틱 프로브의 성능특성)

  • Park, Noh-Joon;Yang, Sang-Hyun;Kong, Tae-Sik;Kim, Hee-Dong;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.46-46
    • /
    • 2010
  • In order to detect exact corona discharge point at stator winding of a rotating machine, an inductively coupled magnetic probe has been developed, which consists of U-shaped and truncated manganese ferrite inductor as a helix. The measured current intensity is somewhat higher than commercially developed probe. It has been shown that the measured intensity of proposed probe is suitable for manual localization as to off-line stator winding monitoring of rotating machine.

  • PDF

Design of Direct Coupled Combline Filter With Tapped Line in/output For Ku-band Satellite Transponder Downconverter (직접 결합 방식의 Tapped Line 입/출력을 갖는 Ku 대역 위성 중계기 주파수 변환기용 Combline 필터의 설계)

  • 염인복;정근욱;박광량;김재명
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.12
    • /
    • pp.22-30
    • /
    • 1997
  • The design procedure for direct coupled combline filter with tapped line in/out was summarized on Ku-band satellite frequency downconverter for stellite application. We calculated the resonator dimensions, spacing between successive resonators, ground plane spacing and tapping position of in/output lines in accordance with the given procedure. Partitions wer eemployed between adjacent resonators by inserting irises to improve filter response characteristis. The designed filter was manufactued with aluminum alloy package to reduce mass, and resonators wer machined from the filter body and in/output lines wer fixed on resonators with epoxy to survive in vibration conditon during launch.

  • PDF

Semi-Lumped Compact Low-Pass Filter for Harmonics Suppression

  • Li Rui;Kim Dong-Il;Choi Chang-Mook
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.3
    • /
    • pp.171-175
    • /
    • 2006
  • In this paper, a new semi-lumped low-pass filter with three finite attenuation poles at stopband is presented. The new structure is composed of a pair of symmetrical parallel coupled-line and a shunted capacitor. With this configuration, three finite attenuation poles can be available for 2nd, 3rd, and 4th harmonics suppression. The research method is based on transmission-line model for tuning the attenuation poles. In order to examine the feasibility of the proposed structure, a low-pass filter based on microstrip structure with harmonics suppression is designed, fabricated, and measured. The experimental results of the fabricated circuit agree well with the simulation and analytical ones.

A Novel Air-Gap Stacked Microstrip 3 dB Coupler for MMIC (공기 절연 적층형 마이크로스트립 구조의 새로운 3 dB 커플러 MMIC)

  • 류기현;김대현;이재학;서광석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.5
    • /
    • pp.688-693
    • /
    • 1999
  • This paper presents a very simple coupled line structure for MMIC which uses stacked microstrip line and does not employ any dielectric process step. For the analysis and optimization of these coupled line structure, HP-Momentum was used. The measured performance of 3 dB coupler shows 23 to 45 GHz broadband characteristics. Additionally, a balanced 2-stage Ka-Band power amplifier which uses the proposed 3 dB coupler, was also fabricated.

  • PDF

Network function Characterizing the General n-Line 2n-Port coupled Transmission System (일반화한 n선로 결합 전송구조의 회로망 함수)

  • 진년강
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.84-90
    • /
    • 1985
  • A general procedure for finding the immittances of a general, uniformly coupled, n-line structure in an inhomogeneous medium is Presented. The expressions derived in terms of the normal modes of the system are in a convenient matrix form and can be used to compute or to derive the explicit expressions for the elements of the In-port immittance matrix. As an example, the closed form expressions for the elements of the admittance matrix of a sym-metrical four-line eight-port structure are given.

  • PDF

Compact Planar Dual-Wideband Bandstop Filters with Cross Coupling and Open-Ended Stepped Impedance Resonators

  • Velidi, Vamsi Krishna;Sanyal, Subrata
    • ETRI Journal
    • /
    • v.32 no.1
    • /
    • pp.148-150
    • /
    • 2010
  • This letter presents the design of a compact bandstop filter (BSF) operating at two frequencies. The proposed BSF consists of open-ended stepped impedance resonators (OSIR) and an end-shorted parallel-coupled microstrip line (E-PCML). The OSIRs are used to achieve the impedance-controlled stopband positions. The wide BSF bandwidths are achieved through enhanced coupling of the E-PCML. Explicit design guidelines are derived using a lossless transmission line model. To validate theoretical predictions, a prototype dual-band BSF operating at 900 MHz and 2,100 MHz with fractional bandwidths of 72% and 36%, respectively, is implemented in microstrip.

Dead Angle Reduction of Single-Stage PFC Using Controllable Coupled Inductors

  • Tavassol, Mohammad Mehdi;Farzanehfard, Hosein;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.78-85
    • /
    • 2015
  • This paper presents a new structure of single-stage flyback power factor correction (PFC) converter with a controllable coupled negative magnetic feedback (NMF) winding. NMF winding is used to reduce the bulk capacitor voltage at high line voltages and light loads. However, it would cause line current distortion at zero crossing condition. In the proposed circuit, a series winding is used with NMF inductor to eliminate the NMF inductor at low line voltages. As a result, the dead angle of the input current, near zero voltage crossing, is eliminated and the power factor is increased. The presented experimental results of the proposed PFC converter confirm the integrity of the new idea and the theoretical analysis.

Design and fabrication of a novel multilayer bandpass filter with high-order harmonics suppression using parallel coupled microstrip filter

  • Fathi, Esmaeil;Setoudeh, Farbod;Tavakoli, Mohammad Bagher
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.260-273
    • /
    • 2022
  • This study presents a novel multilayer structure of parallel coupled-line bandpass filtercentered at 2.42 GHz with a fractional bandwidth value of approximately 19.4%. The designed filter can suppress harmonics with an appropriate frequency response by incorporating different techniques based on the multilayer technique. A combination of different techniques such as radial microstrip stubs and defected ground structure (DGS) and defected microstrip structure techniques are employed to suppress harmonics up to 5f0. These techniques are used in two layers to suppress up to 5f0. In addition, in this study, the effects of different parameters, such as the width of slot-line DGS, the angle of diagonal line slots in the upper layer, and the air gap between the two layers on the filter performance, are investigated. To verify the correct circuit operation, the designed filter is implemented and tested. The measurement results of the proposed filter are compared with the simulation results.

8-port Coupled Transmission Line Modeling of KSATR ICRF Antenna and Comparison with Measurement (커플링이 고려된 KSTAR ICRF 안테나의 8포트 전송선 회로 모델링 및 측정 결과 비교)

  • Kim, S.H.;Wang, S.J.;Hwang, C.K.;Kwak, J.G.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2010
  • It is very important to predict and analyze the change of voltage and current distribution of current strap, abnormal voltage distribution of transmission line and resonance phenomenon by coupling between current straps for more stable operation of ICRF system. In this study, to understand those phenomena by coupling, 8-port coupled transmission line model is completed by appling S-parameter measured in the prototype KSTAR ICRF antenna to the model. The determined self-inductance, mutual-inductance and capacitance of antenna straps are shown to be lower than that calculated from 2D approximate model due to finite length of strap. The coupled transmission line model of current strap will be utilized to the operation of ICRF system of KSTAR in the future.

Elastic Wave Propagation in Monoclinic System Due to Harmonic Line Load

  • Kim, Yong-Yun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.2E
    • /
    • pp.47-52
    • /
    • 1998
  • An analysis of dynamic responses is carried out on monoclinic anisotropic system due to a buried harmonic line source. The load is in the form of a normal stress acting along an arbitrary axis on the plane of symmetry within the orthotropic materials: In case that the line load is acting along the symmetry axis normal to the plane of symmetry, plane wave equation is coupled with verital shear wave and longitudinal wave. However, if the line load is acting along an arbitrary axis normal to the plane of symmetry, plane wave equation is coupled with vertical shear wave, longitudinal wave and horizontal shear wave. We first considered the equation of motion in a reference coordinate system, where the line load is coincident with a symmetry axis of the orthotropic material. Then the equation of motion is transformed into one with respect to general coordinate system with azimuthal angle by using transformation tensor. Plane wave solutions of monoclinic systems are derived for infinite media. Finally complete solutions for the plane harmonic wave are obtained by calculating the inverse of the integral transforms, in which bulk wave poles are avoided by deforming the contour of the integration to the complex plane. Numerical results for examples of orthotropic material belonging to monoclinic symmetry are demonstrated.

  • PDF