• 제목/요약/키워드: Corrosion density

검색결과 744건 처리시간 0.021초

PTA법에 의한 스텔라이트 12 합금 육성층의 특성에 미치는 전류의 영향 (The Effect of Current on Characteristics of Stellite 12 Alloy Overlayer by PTA Process)

  • 정병호;김무길;안용식;김민영;이성열
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.88-94
    • /
    • 2001
  • Stellite 12 alloy-powders were overlaid on 410 stainless steel valve seat using plasma transferred arc(PTA) process. Variation of the microstructure, hardness, wear and corrosion of overlaid deposit with current change was investigated. The deposit showed hypoeutectic microstructure, which was consisted of primary cobalt dendrite and networked $M_7C_3$ type eutectic carbides. As current increased, the amount of eutectic carbide decreased and its dendritic secondary arm spacing increased. Hardness of the deposit was decreased with increase of current. Stress relief heat treatment at $600^{\circ}C$ for two hours resulted in slight increase of hardness in the deposit and showed uniform hardness distribution in base metal without any hardened layer in HAZ. Specific wear decreased with increase of sliding distance. The deposit of high hardness with a lot of eutectic carbide showed relatively low specific wear. Initial corrosion current density of the deposit in 0.1N sulfuric acid was lower than those of 410 stainless steel, and showed a little variation with PTA current.

  • PDF

Study of Corrosion-Induced Failure Mechanisms of Epoxy Coated Reinforcing Steel (Parts I and II)

  • Lee, Seung-kyoung
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.396-401
    • /
    • 1995
  • Epoxy coated reinforcing steels (ECRs) were acquired from ten sources and coatings from each source were initially characterized in terms of defects, thickness, solvent extraction weight loss and hardness. Testing involved exposure in three aqueous solutions at elevated temperature (8$0^{\circ}C$) and in chloride-contaminated concrete slabs under outdoor exposure, It was found that the density and size of coating defects was the promary factor affecting ECR performance. The equivalent circuit analysis using electrochemical impedance spectroscopy (EIS) data indicated that the impedance response for well-performing ECR specimens showed no signs of active degradation at the interface although diffusional processes similar to those noted for poorly performing bars occurred here. Experimental results also indicated a relationship between corrosion behavior and bar source. Weight loss upon solvent extraction correlated with impedance reduction from hot water exposure. Coating defects during most of the tests, especially in high pH solutions containing chloride ions. ECRs with excessive coating defects, either initially present or ones which developed in service, performed poorly in every test category regardless of source. Forms of coating failure were extensive rusting at defects, blistering, wet adhesion loss, cathodic delamination, underfilm corrosion and coating cracks. These occurred sequentially or concurrently, depending on the condition of the ECR and nature of the environment

  • PDF

혼합 산화제를 사용한 텅스텐 막의 전기화학적 부식 및 CMP 특성 (Electrochemical Corrosion and Chemical Mechanical Polishing(CMP) Characteristics of Tungsten Film using Mixed Oxidizer)

  • 나은영;서용진;이우선
    • 한국전기전자재료학회논문지
    • /
    • 제18권4호
    • /
    • pp.303-308
    • /
    • 2005
  • In this paper, the effects of oxidants on tungsten chemical mechanical polishing (CMP) process were investigated using three different oxidizers such as Fe(NO₃)₃, KIO₃ and H₂O₂. Moreover, the interaction between the tungsten film and the oxidizer was discussed by potentiodynamic polarization measurement with three different oxidizers, in order to compare the effects of W-CMP and electrochemical characteristics on the tungsten film as a function of oxidizer. As an experimental result, the tungsten removal rate reached a maximum at 5 wt% Fe(NO₃)₃concentration, and when 5 wt% H₂O₂was added in the slurry, the removal rate of W increased. Also, the microstructures of surface layer by atomic force microscopy(AFM) image were greatly influenced by the slurry chemical composition of oxidizers. It was shown that the surface roughness and removal rate of the polished surface were improved in Fe(NO₃)₃than KIO₃. The electrochemical results indicate that the corrosion current density of the 5 wt% H₂O₂ and 5 wt% H₂O/sub 2+/+ 5 wt% Fe(NO₃)₃was higher than the other oxidizers. Therefore, we conclude that the W-CMP characteristics are strongly dependent on the kinds of oxidizers and the amounts of oxidizer additive.

Orientation Dependent Directed Etching of Aluminum

  • Lee, Dong Nyung;Seo, Jong Hyun
    • Corrosion Science and Technology
    • /
    • 제8권3호
    • /
    • pp.93-102
    • /
    • 2009
  • The direct-current electroetching of high purity aluminum in hot aqueous-chloride solution produces a high density of micrometer-wide tunnels whose walls are made up of the {100} planes and penetrate aluminum in the <100> directions at rates of micrometer per second. In the process of the alternating-current pitting of aluminum, cathodic polarization plays an important role in the nucleation and growth of the pits during the subsequent polarization. The direct-current tunnel etching and alternating-current etching of aluminum are basically related to the formation of poorly crystallized or amorphous passive films. If the passive film forms on the wall, a natural misfit exists between the film and the aluminum substrate, which in turn gives rise to stress in both the film and the substrate. Even though the amorphous films do not have directed properties, their stresses are influenced by the substrate orientation. The films on elastically soft substrate are likely to be less stressed and more stable than those on elastically hard substrate. The hardest and softest planes of aluminum are the {111} and {100} planes, respectively. Therefore, the films on the {111} substrates are most likely to be attacked, and those on the {100} substrates are least likely to be attacked. For the tunnel etching, it follows that the tunnel walls tend to consist of the {100} planes. Meanwhile, the tunnel tip, where active corrosion takes place, tend to be made of four closely packed {111} planes in order to minimize the surface energy, which gives rise to the <100> tunnel etching.

Fe-P-C-B-Al-Mo계 비정질합금의 열적.화학적 성질에 미치는 P 및 Mo의 영향 (The Effect of P and Mo for Thermal and Chemical Properties of Fe-PC-B-Al-Mo Amorphous Alloys)

  • 국진선;전우용
    • 열처리공학회지
    • /
    • 제15권2호
    • /
    • pp.76-81
    • /
    • 2002
  • The melt-spun amorphous $Fe_{77-X}P_{13}C_4B_4Al_2Mo_X$(x=4~10) and $Fe_{82-X}P_XC_4B_4Al_2Mo_8$(x=9~15) alloys were found to exhibit a large supercooled liquid region(${\Delta}T_x$) exceeding 40 K before crystallization. The largest ${\Delta}T_x$ for the glassy alloys containing Mo reaches as large as 65 K for the $Fe_{69}P_{13}C_4B_4Al_2Mo_8$ alloy. The corrosion behavior of the amorphous $Fe_{77-X}P_{13}C_4B_4Al_2Mo_X$(x=4~15) and $Fe_(82-X)P_XC_4B_4Al_2Mo_8$ (x=9~17) alloys were examined by electrochemical measurements in 9M $H_2SO_4$ solution at 303 K. The addition of Mo(or P) for replacing some portion of Fe is effective in improving the corrosion resistance of the investigated Fe-based glassy alloys. They are spontaneously passivated and have a wide passive region with low passive current density.

에폭시계 코팅재의 내산열충격 특성에 관한 연구 (Study on the characteristics of acid resistance and thermal shock for epoxy coatings)

  • 이상열;윤병두
    • 수산해양기술연구
    • /
    • 제43권4호
    • /
    • pp.362-369
    • /
    • 2007
  • This paper was studied on the characteristics of acid resistance and thermal shock for epoxy coatings in the strong acidic environment. The exhaust gas system, such as a air preheater, desulfurization equipment, for industrial boiler is damaged by dew point corrosion. To protect the acid corrosion, the coating using nonmetal was applied. The electrochemical polarization test, acid resistance and thermal shock test for epoxy coatings were carried out. And the acid resistance and thermal shock characteristics, aspect, and electrochemical anti-corrosion characteristics for epoxy coatings in the strong acidic environment were considered. The main results are as followings: As the epoxy glass flake coating by acidic thermal shock was damaged to the crack, blistering and elution etc., the current density of epoxy glass flake coating is high. But the damage of epoxy metal complex coating by acidic thermal shock was not occurred. Therefore the characteristics of acid resistance and thermal shock for epoxy metal complex coating is better than those for epoxy glass flake coating.

BIW 전착도장에서의 컴퓨터 시뮬레이션 적용사례 (Introduction of Computer Simulation for BIW Electrocoating Process)

  • 손대홍;정희진;안승호;김병수;김정연;최병삼
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.78-83
    • /
    • 2016
  • The e-coating to inhibit induced corrosion can deposit a coating not only on the exterior surface but also on the inside of whole metallic components of body-in-white (BIW). But it is difficult to deposit paint films on the inside area because metallic components are multi layered. It may cause shortness of e-coating thickness. The only way to properly verify e-coating thickness is by performing the use of tear-down prototypes. When paint films' thickness is inadequate, a structural modification on each metallic component is needed. Verification of the thickness improvement for a structural modification requires much manual effort and leads to increasing development time. Recently, the simulation technology has been developed to predict the e-coating thickness in e-coating field. By applying the simulation to BIW, improvement in paint thickness quality and shortening of development period are expected. The paper explains a validated solution that allows simulating the effect of design changes to the e-coating thickness and current density, thereby delivering results within a time frame of a few days.

Alloy 600의 결정립계 산화에 대한 표면 변형의 영향 (Effects of Surface Deformation on Intergranular Oxidation of Alloy 600)

  • 하동욱;임연수;김동진
    • Corrosion Science and Technology
    • /
    • 제19권3호
    • /
    • pp.138-145
    • /
    • 2020
  • Immersion tests of Alloy 600 were conducted in simulated primary water environments of a pressurized water reactor at 325 ℃ for 10, 100, and 1000 h to obtain insight into effects of surface deformation on internal and intergranular (IG) oxidation behavior through precise characterization using various microscopic equipment. Oxidized samples after immersion tests were covered with polyhedral and filamentous oxides. It was found that oxides were abundant in mechanically ground (MG) samples the most. The number density of surface oxides increased with time irrespective of the method of surface finish. IG oxidation occurred in mechanically polished (MP) and chemically polished (CP) samples with thin internal oxidation layers. However, IG oxidation was suppressed with relatively thick internal oxidation layers in MG samples compared to MP and CP samples, suggesting that MG treatment could increase resistance to primary water stress corrosion cracking (PWSCC) from the standpoint of IG oxidation. As a result, appropriate surface treatment for Alloy 600 could prevent oxygen diffusion into grain boundaries, inhibit IG oxidation, and finally induce its high PWSCC resistance.

DC Magnetron Sputtering법으로 제작한 Ti$_{x}$N박박의 부식특성에 미치는 코팅조건과 첨가원소의 영향 (Effects of Coating and Additivw Gases on the corrosion Properties of Ti$_{x}$N Films Preapered with DC Magneton Sputtering Method)

  • 김학동;이봉상;조성석
    • 한국표면공학회지
    • /
    • 제31권5호
    • /
    • pp.251-260
    • /
    • 1998
  • Stainless Steel is being used widely for various purposes due to its good corrosion resistance. There have been many researches to produce colored stainless steel by several methods such as anodizing and ion-plating. In this experiment, we $Ti_XN$(C,O) on the films SUS304, aluminium, and glass substrates with DC magentron sputterinng system made by Leybold Hereus, and strdied the structur, corrsion and pit characture of the TiXN observed by TeM image was black and whink and white columnar hed a very fine(200$\AA$) dense sturcture,and the diffraction resistance at the $3{\times}10_6A/\textrm{cm}^2$ and $10_{10}\times{cm}^2$current density were obtained in the under-stoichiometry $Ti_xN$ compound of Ar/$N_2$(Ar:$N_2$=100:6, titanium-rich compound) and the over-stoichiometry compound of Ar/$N_2$((Ar:$N_2$=60:15) respectively. When the thiness was over 1.64$\mu\textrm{m}$, good pit resistance could be obtained and its improvement was especially affected by perfect surfaceface. Typical TiN anodic polarzation curves of very unstable corrosion were observed by $Ti_xN$ film on the glass and perfect film of 3.28$\mu\textrm{m}$ thickness.

  • PDF

침탄된 316L 스테인리스 강의 접촉저항 및 내식 특성 (The Contact Resistance and Corrosion Properties of Carburized 316L Stainless Steel)

  • 홍원혁;고석진;장동수;이정중
    • 한국표면공학회지
    • /
    • 제46권5호
    • /
    • pp.192-196
    • /
    • 2013
  • Stainless steels (AISI 316L) are carburized by Inductively coupled plasma using $CH_4$ and Ar gas. The ${\gamma}_c$ phase(S-phase) is formed on the surface of stainless steel after carburizing process. The XRD peak of carburized samples is shifted to lower diffracting angle due to lattice expansion. Overall, the thickness of ${\gamma}_c$ phase showed a linear dependence with respect to increasing temperature due to the faster rate of diffusion of carbon. However, at temperatures above 500, the thickness data deviated from the linear trend. It is expected that the deviation was caused from atomic diffusion as well as other reactions that occurred at high temperatures. The interfacial contact resistance (ICR) and corrosion resistance are measured in a simulated proton exchange membrane fuel cell (PEMFC) environment. The ICR value of the carburized samples decreased from 130 $m{\Omega}cm^2$ (AISI 316L) to about 20 $m{\Omega}cm^2$. The sample carburized at 200 showed the best corrosion current density (6 ${\mu}Acm^{-2}$).