• 제목/요약/키워드: Corrosion Protection System

검색결과 170건 처리시간 0.031초

TRS를 이용한 해양구조물의 원격 실시간 부식감시 및 방식 제어시스템 개발 (The Development of The Remote Real-Time Corrosion Monitoring and Control System Using by TRS for Maritime Metallic Structures)

  • 배정효;하태현;이현구;김대경;최상봉;정성환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.657-659
    • /
    • 2000
  • The importance of total management for maritime structures (Ports, Piers, docks. marine bridges, marine roads, submarine pipelines, etc.) is more and more increasing in these days. Especially, in spite of the marine structures are exposed at the various corrosion circumstances, there are not only a standard of Cathodic Protection System but also knowledge of importance for necessity of corrosion monitoring. Therefore, this paper presents the results of development for the Remote Real-Time Corrosion Monitoring and Control System Using by TRS on Maritime Metallic Structures which can be prevents a big accident by corrosion.

  • PDF

직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구 (A study of Protection for electrical corrosion by stray current in DC railway system)

  • 이재영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF

Study on New Candidate Coating Materials to Challenge Rudder Cavitation Damage

  • Lee, H.I.;Han, M.S.;Baek, K.K.;Lee, C.H.;Shin, C.S.;Chung, M.K.
    • Corrosion Science and Technology
    • /
    • 제7권5호
    • /
    • pp.274-282
    • /
    • 2008
  • Ships' hull is typically protected by a combination of protective coating system and electrical cathodic protection system, which has been an economical and effective measure for ship's hull to date. However, ships' rudder and adjacent hull areas are known to be subjected to premature corrosion damages, which require more frequent coating repair than other hull areas. Conventional organic coating system for ship's hull has been known only to remain intact just for 2~3 months on the rudder and adjacent area, especially for the fast-going ships such as container carriers or naval vessels. In this study, special organic/inorganic coating materials, which are commercially available, were tested in terms of cavitation resistance as an alternative to existing rudder & hull protection system. Both standard ultrasonic tester and in-house developed ultra water jet test method were employed as a means to evaluate their performance against cavitation induced damages. Additionally, the overall cost evaluation and workability at actual shipyard were discussed.

매설배관의 방식전위 측정시스템 개발에 관한 연구 (A Study on Development of Cathodic Protection on Underground Pipeline Measuring System)

  • 김진준;서민성;김동균
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.66-71
    • /
    • 2014
  • 가스 배관은 도시가스 시설물의 핵심 시설물로 대부분 지하에 매설되어 있으며, 매설 토양의 특성 및 환경적 영향 등으로 인해 배관부식 등의 시설물 손상 위험에 상시 노출되어 있다. 매설배관은 관련법규에 따라 방식 상태나 배관의 방식전위를 주기적으로 측정하고 있다. 본 연구에서는 기존 방식전위 측정시스템의 문제점을 보완하기 위해 매설배관의 방식전위 측정시스템 개발에 관한 연구를 수행하였다. 연구내용은 관련 법규를 만족시키기 위한 방식전위 측정 기준 및 규격, 기준전극 규격 조사와 방식전위 측정시스템 구축을 위한 측정회로 및 데이터 송신 모듈 개발이다. 개발된 시작품의 테스트를 통해 현장 적용성을 검증하고, 선행연구를 통한 보완점과 향후 연구개발 방향에 대하여 고찰하였다.

토양오염방지를 위한 지하저장탱크의 관리 방안 연구 (Management Criteria of Underground Strage Tank for Prevention of Soil Contamination)

  • 김준현;한영한
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

도시철도 전식방지 기술기준에 따른 시험방법 비교분석 (Comparison Analysis of Field Test Methods Based on Technical Criteria of Electrolytic Corrosion Protection in Urban Railway)

  • 김재문;정호성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1885-1891
    • /
    • 2010
  • Recently metropolitan local governments is actively introducing urban railway's expand and light rail transit as a means of new transport system. DC electricity feeder system operating in the domestic urban railway is typically a feedback circuit consisted of the contact wire and electric railway vehicle via rail. But stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit with respect to a given structure. Stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. At the place where the current leaves the rail and metallic structures, electrolytic corrosion may take place. This paper presents comparison analysis of field test methods based on criteria of electrolytic corrosion protection of buried metallic structures adjacent to DC traction systems.

  • PDF

The study on the influence of surface cleanness and water soluble salt on corrosion protection of epoxy resin coated carbon steel

  • Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • 제13권5호
    • /
    • pp.163-169
    • /
    • 2014
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting and power tool treatment as well as contamination of water soluble salt. To study the effect of the surface treatments and contamination, the topology of the treated surface was observed by confocal microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with immersion test of 3.5 wt% of NaCl solution. Consequently, the surface contamination by sodium chloride with $16mg/m^2$, $48mg/m^2$ and $96mg/m^2$ didn't affect the adhesion strength for current epoxy coated carbon steel and blister and rust were not observed on the surface of epoxy coating contaminated by various concentration of sodium chloride after 20 weeks of immersion in 3.5 wt% NaCl aqueous solutions. In addition, the results of EIS test showed that the epoxy-coated carbon steel treated with steel grit blasting and power tool showed similar corrosion protection performance and surface cleanness such as Sa 3 and Sa 2.5 didn't affect the corrosion protectiveness of epoxy coated carbon steel.

희생양극법을 응용한 콘크리트중의 철근부식 억제에 대한 실험적 연구 (An Experimental Study on the Steel Corrosion Control in Concrete by using the Sacrificial Anode System)

  • 문한영;김성수;류재석;김홍삼;김성섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.191-196
    • /
    • 1997
  • Steel is the most used as materials for construction and corrosion expansion of steel due to outdoor corrosive environmental factor bring serious problem on the durability of concrete structures time after time. It is the purpose of this study to see whether it is effective of not, when sacrificial anode method is adapted. Indoor accelerated corrosion testing was carried out to see its effective in a short term. From the mid result, potential of steel in concrete in case of adapting sacrifice anode method satisfacts protection standard value (less than-850mV vs CSE), therefore sacrificial anode method is considered as a proper protection steps against corrosion of steel.

  • PDF

철근콘크리트용 ICCP 양극의 종류별 음극방식 특성 (Characteristics of Cathodic Protection with ICCP Anode in Reinforced Concrete)

  • 정진아
    • Corrosion Science and Technology
    • /
    • 제11권4호
    • /
    • pp.112-119
    • /
    • 2012
  • This paper presents the results of a study of the effectiveness of cathodic protection with insoluble ICCP anode in reinforced concrete structures. Experimental tests were carried out on reinforced concrete specimens with 3 different commercial anodes for ICCP system in order to compare the effectiveness of cathodic protection. Results have shown that the kinds of anode for ICCP is irrelevant to the effectiveness of cathodic protection, In case of ICCP, the performance of cathodic protection has no relationship to the kinds of anode especially in concrete specimens with sea water condition. It has been found slightly more effective at Ti-Rod anode in fresh water condition and Ti-Mesh anode in atmospheric condition.