• Title/Summary/Keyword: Corrosion Potential 부식전위

Search Result 182, Processing Time 0.024 seconds

Prediction of Concrete Corrosion using Electrodchemical Technique (전기화학적인 콘크리트 부식의 예측)

  • 이종권;박지환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.3 no.2
    • /
    • pp.80-83
    • /
    • 2002
  • The effect of chloride content on the corrosion of reinforced bar in concrete was studied. The mixing ratio of the concrete was 1 : 1.78 : 5.35 : 4.73 (water : content : ballast : sand). The studied chloride content was in the range of 0∼3.5 wt%. The corrosion potentials were measured in every week for two years. The copper-copper sulfate electrode (CSE) was employed as a reference electrode. After two years, the corroded structure was examined and compared to measured corrosion potential. Any visible difference was founded in the specimen located indoor and outdoor. The chloride concentration enhanced rusting and reinforced bar, shifting the potential to active range. The results showed good argument with Van daveer criteria. In 3.5 wt% chloride, the potential shifted belong -350 mV after 58week. Specimen in 1.75 wt% chloride, showed the potential between -200 mV∼-350 mV. However those in free chloride solution maintained above -200 mV for the studied period. It can the concluded that the chloride enhanced corrosion of rebar in concrete and the electrochemical potential can be a promising corrosion monitoring technique.

  • PDF

A Study on the Estimation of Steel Corrosion in Concrete Exposed under the Environment of Seawater (해양환경하에 방치한 콘크리트중의 철근의 부식 추정에 대한 연구)

  • 문한영;김성수;류재석
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.129-137
    • /
    • 1994
  • This study was performed for the purpose of obtaining the fundamental data to establish the criterion of concrete deterioration and presuming steel corrosion of concrete structures under the environment of seawater. Steel embedded concrete specimens were exposed in seawater for 1year. The soluble chloride content in concrete, corrosion potential and steel corrosion were considered. The results show that soluble chloride content in concrete was decreased with lower water-cement ratio and with mineral admixtures. Half-cell potential is reduced with steel corrosion. Corrosion area ratio is correlative with half-cell potential.

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide (포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가)

  • Kim, Soo-Young;Ryu, Hwa-Sung;Kim, Sung-Kil;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.66-74
    • /
    • 2013
  • In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

Evaluation of Corrosion Fatigue Life of TMCP Steel Using the DCPD Method (DCPD 법을 이용한 TMCP 강의 부식피로수명 평가)

  • Park, Jin-Hyung;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.220-225
    • /
    • 2003
  • In order to develop a method of corrosion fatigue design and estimate reliability of TMCP steel using as the material of heavy industries and plants, its corrosion susceptibilities and corrosion fatigue life considering corrosion degradation were investigated. From the results, the corrosion characteristic of TMCP steel is very susceptible in 3.5wt.% NaCl solution. Its susceptibility was linearly increased with the solution temperature increase. The potential difference due to the crack growth behavior in $25^{\circ}C$, 3.5wt.% NaCl solution is very susceptible. And it was found that stress amplitude has a linear relationship with the critical potential. Therefore, it is expected that the corrosion fatigue life of TMCP steel can be nondestructively predicted using the DCPD method.

  • PDF

The Study on the Corrosion Behavior of Al-alloy Radiator for Automobile in Fresh Water (청수 중에서 자동차용 Al합금 방열기의 부식거동에 관한 연구)

  • 임우조;이상열;윤대영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.4
    • /
    • pp.265-270
    • /
    • 2002
  • Most of all the mechanical devices are becoming more high-speed and high-power as well as their used condition being more pollution with rapid development in industrial part. So, it is necessary for these devices to equip cooling system to overcome that kind of severe using condition. Industrial development and income increase causes rapid increase in using fossilenergy and it results in accelerating environmental pollution owing to the increasement in emission of air pollution substance. Specially, fresh water like stream and river water is acidified. Therefore, corrosion damage is accelerated in radiator for automobile that is using acidified water. So, in this study, corrosion test was carried out in distilled and tap water for the investigation on the corrosion behavior of Al-alloy that is using as material for radiator of automobile The main results obtained are as follows According to increase of temperature, open circuit potential is decreased in fresh water. And open circuit potential after deaeration is lower than that before deaeration. Corrosion current density in distilled water is less drained than that of tap water. And Corrosion current density after deaeration is less drained than that before deaeration.

A Study on the Crevice Corrosion for Ferritic Stainless Steel (페라이트 스테인리스강의 틈부식에 대한 연구)

  • Baik Shin-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.51-54
    • /
    • 2004
  • In recently days, the breed fish farm is increased in the beach side for farming fish. In such a farm, the heater is requested for preventing freezing in cold season. The heating material are requested high corrosion resistance and strength for endurance high corrosive salt and pressure. In case of low corrosion resistance and/or strength, the heating element shall be broke down and eventually make spillage or leaking contaminated salt. In the most cases, crevice corrosion is localized form of corrosion usually associated with a stagnant solution on the micro-environmental level. In this study, the crevice corrosion of Ferritic type 430 stainless steel is investigated. The size of specimen is $15{\times}20{\times}3mmt$. Test solution is 1N H2SO4 + 0.05N NaCl. The artificial crevice gap size is $0.24{\times}3{\times}15mmL$. Crevice corrosion is measured under applied voltage 300mV(SCE) to the external surface. the result of this study showed that 1) the induced time for initiation of crevice is 750seconds, 2) potential is dropped in the crevice from the top of gap opening from -320 to -399mV. The result confirmed that the potential drop(IR mechanism) in the crevice is one of mechanism for crevice corrosion.

  • PDF

The Study on the Corrosion Behavior of STS 304 for Gas Boiler in the Condensed Water (응축수 중에서 가스보일러용 STS 304의 부식거동에 관한 연구)

  • Du Yun Byoung;Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.21-25
    • /
    • 2005
  • This paper was studied on the corrosion behavior of STS 304 for gas boiler in the condensed water, the electrochemical polarization test of STS 304 for gas boiler in the condensed water was carried out. And the corrosion behavior of STS 304 was considered. The main results are as following: 1) As corrosion environment is acidified from neutrality, the polarization resistance of STS 304 decreases and the corrosion potential is less noble. 2) The corrosion reaction mechanism of STS 304 is cathodic control. 3) As corrosion environment is acidified, the passive potential range of STS 304 decreases. Also, the passive current density of STS 304 increases.

  • PDF

A Study on the Crevice Corrosion Behavior of Chromium Plating (크롬도금의 틈부식 거동에 관한 연구)

  • 곽남인;임우조
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.4
    • /
    • pp.324-328
    • /
    • 2003
  • This study was made on the crevice corrosion behavior of chromium plating in fresh water. Under the various crevice, the electrochemical polarization test of chromium plating was carried out. Results are discussed In terms of corrosion potential, polarization resistance, corrosion current density and cathodic control of chromium plating.

Effect for Steel Corrosion Protection in Concrete applying Surface Coating Anode and Solar Battery (표면(表面) 코팅 양극(陽極)과 태양전기(太陽電氣)를 이용한 콘크리트 중의 철근(鐵筋) 부식(腐食) 방지(防止)를 위한 효과)

  • Kim, Jong-Pil;Park, Kwang-Pil;Kim, Seong-Soo;Jung, Ho-Seop;Lee, Seung-Tae
    • Resources Recycling
    • /
    • v.18 no.4
    • /
    • pp.44-51
    • /
    • 2009
  • In order to verify the effect of Surface Coating Anode and Solar Battery anode system, accelerated tests in the presence or absence of some chloride content and cracks were carried out. The potential-decay, protection potential and corrosion current density of reinforcing steel in concrete specimen were measured to evaluate the effectiveness of the system. From the test results, the application of the system led to the satisfaction on NACE's criterion in all mixtures of concrete. Additionally it was found that protection potential and corrosion current density were satisfied due to the application of Surface Coating Anode and Solar Battery anode system.

An Experimental Study on Relationship Between Half-Cell Potential and Corrosion Current Density of Chloride-Induced Corroded Steel in Concrete (염해에 따라 콘크리트 속에서 부식된 철근의 반전지전위와 부식전류밀도의 상관관계에 관한 실험적 연구)

  • Jo, Sang-Hyeon;Kim, Dong-Won;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.1-13
    • /
    • 2022
  • This study aims to investigate the feasibility of the half-cell potential (HCP) measurements on the concrete surface for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete. A series of experimental study is performed to measure HCP (or corrosion potential, Ecorr) and corrosion current density (icorr) of reinforcing steel in concrete cube specimens, with a side length of 200 mm. Various corrosion levels in a range of 0% to 20% of the test specimens are accelerated by impressing current to the reinforcing steel in concrete immersed in 3.0 % NaCl solution. HCP is measured in accordance with ASTM C876-15, and corrosion current density is determined by using the Stern-Geary equation and measured polarization resistance measured by electrochemical impedance spectroscopy (EIS). As a result, a numerical formula that relates HCP and icorr in the test specimen is established by a regression analysis of the measured data in this study. It is observed that HCP is linearly correlated with log(icorr) with a R2 greater than 0.87, which is less affected by the experimental variables such as concrete mixture proportion, diameter of reinforcing steel and the amount of applied current in this study. These results exhibit that HCP measurements could be effective for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete in the case of exposed to a certain consistent environment.