DOI QR코드

DOI QR Code

A Study on the Anti-corrosion Properties of Organic and Inorganic Inhibitor by Electrochemical Evaluation Method in Saturated Aqueous Solution of Calcium Hydroxide

포화 수산화칼슘 수용액 내에서의 무기계 및 유기계 방청제의 전기화학적 방식 특성평가

  • Received : 2013.03.19
  • Accepted : 2013.04.15
  • Published : 2013.07.30

Abstract

In this study, corrosion potential ($E_{corr}$), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors' relationship to Ecorr, corrosion rate, and polarization resistance was not shown.

본 연구에서는 부동태피막형 무기계 방청제와 흡착형 유기계 방청제를 대상으로, 시멘트세공용액을 모사한 포화 수산화칼슘 수용액내에서 염화물이온 농도와 방청성분 몰비를 변수로 하여 Potentiostat을 사용하여 부식전위, 부식속도, 분극저항을 측정하여 방식성능을 평가하였다. 그 결과, 무기계 방청제는 방청몰비 약 1.2 이상에서 방식성능을 확보하는 것으로 나타났고, 유기계 방청제는 방청몰비 약 0.3 이상에서 방식성능을 확보하는 것으로 나타났다. 또한, 부식속도와 분극저항, 부식속도와 부식전위의 관계는 선형 반비례 경향을 나타냈고, 분극저항과 부식전위는 선형 비례하는 것을 알 수 있었으며, 부식전위, 부식속도, 분극저항과의 상관관계는 유기계와 무기계 방청제에서 큰 차이가 없는 것으로 나타났다.

Keywords

References

  1. Ann, K. Y., Jung, H. S., Kim, H. S., Kim, S. S., Moon, H. Y., "Effect of calcium nitrite-based corrosion inhibitor in preventing corrosion of embedded steel in concrete", Cement and Concrete Research, Vol. 36, Issue 3, 2006, pp.530-535. https://doi.org/10.1016/j.cemconres.2005.09.003
  2. Ann, K. Y., Song, H. W., "Chloride threshold level for corrosion of steel in concrete", Corrosion Science, Vol. 49, Issue 11, 2007, pp.4113-4133. https://doi.org/10.1016/j.corsci.2007.05.007
  3. Ann, K. Y., "Enhancing the Chloride Threshold Level for Steel Corrosion in Concrete", Imperial College, UK, Doctoral Thesis, 2005, pp.1-254.
  4. Charles K. Nmai, "Multi-functional organic corrosion inhibitor", Cement and Concrete Composites, Vol. 26, Issue 3, 2004, pp.199-207. https://doi.org/10.1016/S0958-9465(03)00039-8
  5. Cho, H. K., Yoo, J. H., L, H. S., "Experimental Study on the Penetration Depth and Concentration of Corrosion Inhibitor Using Press-in Method Into the Inside of Concrete", Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 13, No. 5, 2009, pp.160-168 (in Korean).
  6. Glass, G. K. and Buenfeld, N. R., "The Pressentation of the Chloride Threshold Level for corrosion of Steel in Concrete", Corros Sci., Vol. 39, No. 5, 1997, pp.1003-1013.
  7. Manfredi, C., Mozhi, T. A., Wilde, B. E., "Corrosion of carbon steel in saturated brine at 150C-the effects of pH", National Association of Corrosion Engineering, Vol. 45, No. 2, February 1989, pp.172-177.
  8. Moon, B. C., Yoo, J. H., Lee, H. S., Lee, M. S., "An Experimental Study on the Development of Motar Setting Time Control of Nitrate Corrosion Inhibitor and the Evaluation of Corrosion Protection Effect for Electrochemical", Journal of the Architectural Institute of Korea, Vol. 25, No. 1, January, 2009 (in Korean).
  9. Saraswathy, V. and Song, H. W., "Performance of Galvanized and Stainless Steel Rebars in Concrete under Macrocell Corrosion Conditions", Mat Corrosm, Vol. 56, No. 10, 2005, pp.685-691. https://doi.org/10.1002/maco.200503888
  10. So, H. S., "Environmental Influences and Assessment of corrosion Rate of Reinforcing Bars using the Liner Polarization Resistance Technique", Journal of the Architectural Institute of Korea, Vol. 22, No. 2, February, 2006 (in Korean).
  11. Song, H. W. And Ann, K. Y., "Chloride Threshold Level for Corrosion of Steel in Concrete", Corros Sci., Vol. 49, Issue 11, 2007, pp.4113-4133. https://doi.org/10.1016/j.corsci.2007.05.007
  12. Song, H. W., Lee, C. H., Ann, K. Y., "Factors Influencing Chloride Transport in Concrete Structures Exposed to Marine Environment", Cem Concr Comp, Vol. 30, Issue 2, 2008, pp.113-121. https://doi.org/10.1016/j.cemconcomp.2007.09.005
  13. Song, H. W., Lee, C. H., Lee, K. C., Ann, K. Y., "A Study on Chloride Threshold Level of Polymer Inhibitive Coating Containing Calcium Hydroxide", Journal of the Korea Concrete Institute, Vol. 20, No. 6, December, 2008, pp.713-719 (in Korean). https://doi.org/10.4334/JKCI.2008.20.6.713
  14. Song, H. W., Lee, C. H., Lee, K. C., Ann, K. Y., "A Study om Chloride Threshold Level of Blended Cement Mortar Using Polarization Resistance Method", Journal of the Korea Concrete Institute, Vol. 21, No. 3, June, 2009, pp.245-253 (in Korean). https://doi.org/10.4334/JKCI.2009.21.3.245