• Title/Summary/Keyword: Correction methods

Search Result 2,011, Processing Time 0.036 seconds

Stretch-free Normal Moveout Correction (Stretch가 없는 수직 시간차 보정)

  • Pyun, Sukjoon
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.4
    • /
    • pp.232-240
    • /
    • 2017
  • Normal moveout correction is one of the main procedures of seismic reflection data processing and a crucial pre-processing step for AVO analysis. Unfortunately, stretch phenomenon, which is the intrinsic problem of NMO correction, degrades the quality of stack section and reliability of AVO analysis. Although muting is applied to resolve this problem, it makes far-offset traces more useful to develop an advanced NMO correction technique without stretch. In this paper, easy and detailed explanations are provided on the definition and methodology of NMO correction, and then the cause of stretch is explained with its characteristics. A graphical explanation for NMO correction is given for the intuitive understanding of stretch phenomenon. Additionally, the theoretical formulation is derived to quantitatively understand the NMO correction. Through explaining the muting process to remove NMO stretch, the limitations of conventional methods are investigated and the need for a new resolution comes to discussion. We describe a stretch-free NMO correction based on inverse theory among many different stretch-free NMO corrections. Finally, the stretch-free NMO correction is verified through synthetic example and real data.

Pulse pile-up correction by auto-regression on linear operations (ARLO) method: A comparison with integration-based algorithms

  • Mohammad-Reza Mohammadian-Behbahani
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3904-3913
    • /
    • 2024
  • Radiation detection at high count rate suffers from pulse pile-up, where the counting data and energy information of the system are affected by the overlapping of the system output pulses. There exist various pile-up correction strategies to recover the true information of the pulses, among which pulse-tail extrapolation is a well-known method focused on in this study. Present work aims to use a mono-exponential model for extrapolating the pileup-distorted trailing edge of a pulse, to provide a reference line for calculating the true amplitude of its subsequent overlapping pulse. To this goal, the auto-regression on linear operations (ARLO) method is examined and compared with two integration-based methods (the Foss and the Matheson methods), as well as the non-linear least squares (NLS) method. Despite a higher sensitivity to noise, the ARLO method was able to provide a simple, non-iterative solution with a performance over 400 times faster than the NLS algorithm, according to the analysis of a high count rate set of experimental pulses from a NaI(Tl) detection system. Foss and Matheson methods also provided solutions reasonably faster than NLS (but not surpassing ARLO), performing exactly the same as each other with results very close to NLS, benefiting from their non-iterative nature.

Determination of Attenuation Collection Methods According to the Type of Radioactive Waste Drums (방사성폐기물드럼 종류별 감쇠보정방법의 결정)

  • Kwak, Sang-Soo;Choi, Byung-I1;Yoon, Suk-Jung;Lee, Ik-Whan;Kang, Duck-Won;Sung, Ki-Bang
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.309-317
    • /
    • 1997
  • The measured radioactivity of gamma-emitting radionuclides in each radioactive waste drum using the non-destructive waste assay method is underestimated than real radioactivity in radioactive waste drum because the gamma-rays are attenuated within the medium. Therefore, the measured radioactivity should be corrected for the attenuation of gamma-rays. For the correction of the attenuation of gamma-rays, the attenuation correction method should be applied differently by considering the distribution and density of medium in radioactive wastes drum generated from nuclear power plants. In this study, the model drums were fabricated for simulating five types of radioactive waste drums generated from nuclear power plant and the optimum methods of the attenuation correction were experimentally determined to analyze the activity of radionuclides in the waste drum accurately using the segmented gamma scanning system. With the determination of the attenuation correction methods from the experimental results the transmission method and the average density method for the miscellaneous waste drum, the transmission method and the differential peak absorption method for the shielded miscellaneous waste drum were used to measure the density of medium in waste drums. Also, the average density method and the differential peak absorption method for the spent resin drum, the paraffin solidified drum, and the spent filter drum were used.

  • PDF

RICHARDSON EXTRAPOLATION AND DEFECT CORRECTION OF MIXED FINITE ELEMENT METHODS FOR ELLIPTIC OPTIMAL CONTROL PROBLEMS

  • Chen, Yanping;Huang, Yunqing;Hou, Tianliang
    • Journal of the Korean Mathematical Society
    • /
    • v.49 no.3
    • /
    • pp.549-569
    • /
    • 2012
  • In this paper asymptotic error expansions for mixed finite element approximations to a class of second order elliptic optimal control problems are derived under rectangular meshes, and the Richardson extrapolation of two different schemes and interpolation defect correction can be applied to increase the accuracy of the approximations. As a by-product, we illustrate that all the approximations of higher accuracy can be used to form a class of a posteriori error estimators of the mixed finite element method for optimal control problems.

Modeling and Implementation of Context based Annotation for XML Documents

  • Sohn, Won-Sung;Ko, Myeong-Cheol;Kim, Jae-Kyung;Lim, Soon-Bum;Choy, Yoon-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.4
    • /
    • pp.565-575
    • /
    • 2003
  • This paper proposed context based annotation model and annotation ambiguity correction methods. The proposed model provides various annotation types, semantic models, and pen-based free drawing interface. Annotation correction method that is specifically based on the context which includes various textual and structure information between free-form marking and annotation. Also, interface for XML environment using the proposed model and correction methods is proposed and possibilities of application is looked at. The results from the implementation of the proposed method show that the annotated areas included in the free-form marking information are more accurate, achieving more accurate exchange results amongst multiple users in a heterogeneous document environment

  • PDF

The phase correction method for the interferometer direction-finding system (인터페로미터 방향탐지 시스템의 위상보정 방법)

  • Lee, Jung-hoon;Jo, Jeil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.355-356
    • /
    • 2018
  • An interferometer is antenna system composed fo two or more elements that can be used to determine the diretion of arrival (DOA) of a received signal by measuring the relative phase between receiving elements. In order to minimize the error of the direction-finding accuracy in interferometer direction-finding system (DFS), the phase correction is accomplished. In this paper, the several methods for the phase correction are classified and the advantage and disadvantage of those methods are compared.

  • PDF

Reconstruction of Philtral Column with Overlapping of Orbicularis Oris Muscle Flap in Secondary Cleft Lip Nose Deformity (이차성 구순열 환자에서 상구순 구륜근 피판중첩을 이용한 인중주의 재건)

  • Kwon, Seok Min;Park, Jun;Yang, Won Yong;Yoo, Young Cheun;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.574-580
    • /
    • 2008
  • Purpose: Philtral deformity is a stigma of secondary cleft lip nose. It occurs from the false arrangement of orbicularis oris muscle and the scar of previous operation. Various methods have been used to correct this deformity. We successfully corrected philtral deformity using overlapping of orbicularis oris muscle flap. Methods: From November 2000 to August 2007, we performed 39 cases of correction of philtral deformity in secondary cleft lip nose with overlapping of orbicularis oris muscle flap. Their age ranged from 5 to 53 years old. Existing scar tissue of previous operation was deepithelialized and preserved as scar flap. Lateral orbicularis oris muscle flap was elevated, advanced and overlapped upon medial muscle flap after dissection of orbicularis oris muscle of both sides. Reconstruction of philtral column was made from overlapping area by fixation of end part of lateral muscle flap to the point between philtral dimple and column. The degree of muscle flap advancement was decided by correction state of lateral muscle bulging. Correction of nostril floor depression or whistle deformity was also performed with preserved scar flap, if necessary. Results: Realignments of orbicularis oris muscle were possible in the majority of the patients and final results of philtral reconstruction were satisfactory mostly. Correction of nostril floor depression and whistle deformity was also achieved. Additional correction was performed later to 4 patients in whom insufficient reconstruction was noted. No significant complication was observed. Conclusion: More natural and symmetric philtrum was acquired with overlapping of orbicularis oris muscle flap. To the authors' knowledge, it is an easy and effective method for correction of philtral deformity through anatomical rearrangement of distorted orbicularis oris muscle with relatively simple procedure.

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.

A COMPARATIVE STUDY ON THE CORRECTION METHODS OF NOSTRIL IN PATIENTS WITH CLEFT LIP NASAL DEFORMITY (구순열비변형 환자에서 비교정술에 대한 비교 연구)

  • Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.287-294
    • /
    • 2006
  • The secondary correction of cleft lip nasal deformity (CLND) presents difficult surgical problems. Characteristically, nostrils are asymmetric. The present study was aimed to examine and compare the effect of Straith's alar web Z-plasty, Millard's alar web Z-plasty, alar web excision, and lateral V-Y advancement of the alar base for augmentation of the nostril with or without lengthening the columella in CLND. The subjects were 28 patients with unilateral cleft lip, who had secondary nostril correction. The nostril correction methods were Straith's alar web Z-plasty, Millard's alar web Z-plasty, alar web excision, and lateral V-Y advancement of the alar base. Facial photographs were taken before and 20 days after the operation. By using Adobe photoshop, the columella length and the nostril width were measured from the facial frontal photograph and Worm's eye view. The degree of improvement was calculated and statistically analyzed. The degree of improvement of the columella length using Straith's alar web Z-plasty was 70.20%. And then Millard's alar web Z-plasty was 55.01%, alar web excision was 39.93%, and lateral V-Y advancement of the alar base was 16.38% in order. The degree of improvement of the nostril size using lateral V-Y advancement of the alar base was 55.26%. And then alar web excision was 52.72%, Millard's alar web Z-plasty was 34.86%, and Straith's alar web Z-plasty was 16.06% in order. Straith's alar web Z-plasty and Millard's alar web Z-plasty resulted in elongation of the columella, equalization of asymmetrical nostril, and enlargement of small nostrils. Alar web excision enlarged nostrils and restored symmetry. Lateral VY advancement of the alar base increased nostril width and enlarged nostrils. These results indicate that the correction of nostrils improve the shape and the symmetry of the nostrils in CLND.

A Simple Evaluation Method Using a "Sun-Wukong's Headband" Wire for Positional Plagiocephaly Correction after Cranial Remodeling Helmet Therapy (손오공 머리띠를 이용한 간편한 사두증 치료결과 평가방법)

  • Kim, Peter Chanwoo;Lee, Young Bae;Park, Dae Hwan
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.28-32
    • /
    • 2011
  • Purpose: A cranioremodeling helmet for correcting plagiocephaly was recently developed. However, no discrete objective methods to evaluate how the deformity is being corrected have been developed. We have established an easy and cost-effective method that can be used not only to show the correction process, but can also be used by physicians to assess the degree of plagiocephaly two-dimensionally. Methods: For two-dimensional evaluation, a length of malleable memory wire (2 mm in diameter) resembling "Sun-Wukong's headband" was placed on the patient's head. The wire around the patient's head was positioned on a plane including points 1 cm above the eyebrow and 1 cm above the auricle. The wire was placed on a sheet of paper and the outline was marked using pens of various colors during each visit. The degree of plagiocephaly correction could then be shown to the patient's parents at every consultation. Results: The method established by the present study easily shows the horizontal cross-section transformation of the head, illustrates plagiocephaly correction by the helmet, and shows the degree of correction in a two-dimensional manner. Conclusion: A soft-shell helmet is widely used for correcting plagiocephaly. However, evaluating the effectiveness of the helmet has been determined in a subjective manner, and a more objective method is now in demanded. Our study found that a "Sun-Wukong's headband" wire can accurately measure two-dimensional changes. Future studies will be required to identify landmarks needed for assessing plagiocephaly correction.