• Title/Summary/Keyword: Correction effect

Search Result 1,355, Processing Time 0.03 seconds

Scale Effect Corrections of NREL Phase VI Wind Turbine by Using Computational Fluid Dynamics (전산유체역학을 이용한 NREL Phase VI 풍력터빈의 축소효과 보정)

  • Park, Young-Min;Chang, Byeong-Hee
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.54-62
    • /
    • 2007
  • The present paper describes the scale effect correction methods for scaled NREL Phase VI wind turbines by using CFD[computational fluid dynamics). For the corrections of wind turbine scale effect, various researches on the helicopter rotor scale effect were investigated and the feasibility study of the methods was performed to correct wind turbine scale effect. The present paper also introduces scale effect correction methods based on two dimensional lift slope. In order to test the present method, performance analyses of NREL Phase VI wind turbines under various scale conditions were carried out and new correction method was applied. Granting that the new correction method is valid only above Reynolds No. 100,000, it showed reasonable agreement between model and full scale wind turbines in the linear torque region.

  • PDF

Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons (고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수)

  • Park, Cheol-Woo;Lee, Jae-Seung;Kweon, Dae-Chel;Cha, Dong-Soo;Kim, Jin-Soo;Kim, Kyoung-Keun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

Analysis of MSAS Correction Information and Performance in Korea (MSAS 보정정보 분석 및 국내 적용 시 성능 평가)

  • Jeong, Myeong-Sook;Kim, Jeong-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.372-382
    • /
    • 2009
  • A GNSS software for processing the SBAS correction data is developed, and Japan MSAS correction data is analyzed. MSAS orbit correction data is analyzed and compared with WAAS data. MSAS ionosphere correction data is analyzed and the effect of the equatorial anomaly on the correction accuracy is discussed. Degradation due to receive delay of correction information and effect of the degradation on protection level analyzed using partial remove of MSAS correction information. Integrity and availability for precision approch using the MSAS system analyzed.

Scale Effect Correction for NREL Phase VI Wind Turbine (NREL Phase VI 풍력터빈의 축소효과 보정)

  • Park, Young-Min;Chang, Byeong-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.241-244
    • /
    • 2006
  • The present paper describes the scale effect correction method for wind turbine by using CFD(computational fluid dynamics). For the correct ions of wind turbine scale effect, various researches on the helicopter rotor scale effect were Investigated and feasibility study of methods was performed to correct wind turbine scale effect The present paper also introduces new scale effect correction method based on two dimensional lift slope modification. In order to test the Present method, performance analyses of NREL Phase VI wind turbines under various scale conditions were carried out by using CFD. The present method showed reasonable results when applied to NREL Phase VI wind turbine.

  • PDF

A Simple Fault Correction Method for Rotor Position Detection of Brushless DC Motor using a Latch Type Hall Effect Sensor

  • Baik In-Cheol;Joo Hyeong-Gil
    • Journal of Power Electronics
    • /
    • v.5 no.1
    • /
    • pp.62-66
    • /
    • 2005
  • A simple fault correction method for rotor position detection of a brushless DC(BLDC) motor with trapezoidal back EMF(electromotive force) using a Hall effect latch unit is presented. The reason why the Hall effect latch unit does not operate properly during the startup of a BLDC motor is thoroughly explained. To solve this problem, a simple code change method and its hardware implementation issues are proposed and discussed.

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Comparison of Normalization Methods for Defining Copy Number Variation Using Whole-genome SNP Genotyping Data

  • Kim, Ji-Hong;Yim, Seon-Hee;Jeong, Yong-Bok;Jung, Seong-Hyun;Xu, Hai-Dong;Shin, Seung-Hun;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.6 no.4
    • /
    • pp.231-234
    • /
    • 2008
  • Precise and reliable identification of CNV is still important to fully understand the effect of CNV on genetic diversity and background of complex diseases. SNP marker has been used frequently to detect CNVs, but the analysis of SNP chip data for identifying CNV has not been well established. We compared various normalization methods for CNV analysis and suggest optimal normalization procedure for reliable CNV call. Four normal Koreans and NA10851 HapMap male samples were genotyped using Affymetrix Genome-Wide Human SNP array 5.0. We evaluated the effect of median and quantile normalization to find the optimal normalization for CNV detection based on SNP array data. We also explored the effect of Robust Multichip Average (RMA) background correction for each normalization process. In total, the following 4 combinations of normalization were tried: 1) Median normalization without RMA background correction, 2) Quantile normalization without RMA background correction, 3) Median normalization with RMA background correction, and 4) Quantile normalization with RMA background correction. CNV was called using SW-ARRAY algorithm. We applied 4 different combinations of normalization and compared the effect using intensity ratio profile, box plot, and MA plot. When we applied median and quantile normalizations without RMA background correction, both methods showed similar normalization effect and the final CNV calls were also similar in terms of number and size. In both median and quantile normalizations, RMA backgroundcorrection resulted in widening the range of intensity ratio distribution, which may suggest that RMA background correction may help to detect more CNVs compared to no correction.

The Awareness Survey of Vision Correction Surgery Side Effect (시력교정술 부작용 인지도 조사)

  • Lee, Jeung-Young;Seo, Jung-Ick;Park, Eun-Kyoo
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.737-741
    • /
    • 2016
  • Purpose. To investigate awareness of vision correction surgery side effects and investigated side effects affect vision correction surgery decisions. Methods. This study was performed on 85 college students. The awareness of vision correction surgery, the awareness of vision correction surgery side effects, and investigated side effects affect surgery decisions. Results. 37.6 % (32 people) replied that the drying effects is representative side effects of the eye correction surgery. 68.2% (58 people) answered the reason of eye surgery is uncomfortable wearing glasses. 74.1%(63 people) answered the side effects does not affect vision correction surgery decision. Prior to hear a description of side effects, 31.8% percent people hope the surgery. after listening to explain of side effects, only 10.6% percent people hope the surgery. Conclusions. People who want to get vision correction surgery should check their vision condition through prior examination and consultation. What side effects in the operation should be reviewed. That is the only way to reduce side effects.

Coincidence summing correction for a voluminous 152Eu source

  • Yoon, Eun Taek;Kang, Min Young;Kim, In Jung;Sun, Gwang Min;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1266-1270
    • /
    • 2020
  • A code is developed to correct for the coincidence summing effect in detecting a voluminous gamma source, and this code is applied to a152Eu standard source as a test case. The source is 1000 mL of liquid in a cylindrical shape. To calculate the coincidence summing effect, the cylindrical source is considered as 10(radial) × 8(height) sectional sources. For each sectional source, the peak efficiency and total efficiency are obtained by Monte Carlo simulation at each energy for 10 energies between 50 keV and 2000 keV. The efficiencies of each sector are then expressed as polynomials of gamma energy. To calculate the correction coefficients for the coincidence summing effect, the KORSUM code is used after modification. The magnitudes of correction are 4%-17% for the standard 152Eu source measured in this study. The relative deviation of 4.7% before the coincidence correction is reduced to 0.8% after the correction is applied to the efficiency based on the measured gamma line. Hence, this study has shown that a new method has been developed that is applicable for correcting the coincidence effect in a voluminous source, and the method is applied to the measured data of a standard 152Eu cylinder source.

Numerical Study on the Correction of Sea Effect in Magnetotelluric (MT) Data

  • Yang, Jun-Mo;Yoo, Hai-Soo
    • Journal of the Korean earth science society
    • /
    • v.30 no.5
    • /
    • pp.550-564
    • /
    • 2009
  • When magnetotelluric (MT) data are obtained in the vicinity of the coast, the surrounding seas make it difficult to interpret subsurface structure, especially the deep part of the subsurface. We introduce an iterative method to correct the sea effect, based on the previous topographic correction method that removes the distortion due to topographic changes in seafloor MT data. The method first corrects the sea effect in observed MT impedance, and then inverts corrected response in a model space without the sea. Due to mutual coupling between the sea and the subsurface structure, the correction and inversion steps are iterated until the changes in each result become negligible. The method is tested for 1- and 2-D structures using synthetic MT data produced by 3-D forward modeling including surrounding seas. In all cases, the method closely recovers the true structure assumed to generate synthetic responses after a few iterations.