• Title/Summary/Keyword: Corporation performance

Search Result 1,798, Processing Time 0.035 seconds

Development and Performance Verification of Real-time Hybrid Navigation System for Autonomous Underwater Vehicles

  • Kim, Hyun Ki;Jung, Woo Chae;Kim, Jeong Won;Nam, Chang Woo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.5 no.2
    • /
    • pp.97-107
    • /
    • 2016
  • Military Autonomous Underwater Vehicle (AUV) is utilized to search a mine under the sea. This paper presents design and performance verification of real-time hybrid navigation system for AUV. The navigation system uses Doppler Velocity Log (DVL) integration method to correct INS error in underwater. When the AUV is floated on the water, the accumulated error of navigation algorithm is corrected using position/velocity of GPS. The navigation algorithm is verified using 6 Degree Of Freedom (DOF) simulation, Program In the Loop Simulation (PILS). Finally, the experiments are performed in real sea environment to prove the reliability of real-time hybrid navigation algorithm.

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong;Kwon Boo-Kil
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.329-334
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performances of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after about six-year-use of the regulators.

Analysis of Low Power Consumption AMOLED Displays on Flexible Stainless Steel Substrates

  • Hack, Mike;Hewitt, Richard;Ma, Ray;Brown, Julie J.;Choi, Jae-Won;Cheon, Jun-Hyuk;Kim, Se-Hwan;Jang, Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.58-61
    • /
    • 2007
  • We present simulations and results to demonstrate the viability of stainless steel foil as a substrate for low power consumption, flexible AMOLED displays. Using organic planarization layers, we achieve very smooth surface properties, resulting in excellent TFT performance, that can be repetitively flexed without significantly affecting device performance. The use of phosphorescent OLEDs enables the design of low power consumption 40" AMOLED displays.

  • PDF

The Performance Test of the Surge Protector Devices(SPD) and the Selected Methods (써지 보호기 성능 시험 및 선정 기준에 관한 연구)

  • Hong, Sung-Taek;Shin, Gang-Wook;Lee, Dong-Keun;Lee, Eun-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.70-72
    • /
    • 2005
  • Electronic control systems adopted in water treatment facilities. And many water treatment facilities are operated by electrical and electronic devices or by remote control. So those are damaged by the surge which is generated by lightning inevitably. This study is intended to measure and analyze the SPD performance tests occurred at the electrical and electronic control devices and to show the methods of the reduction when the surge is occurred suddenly.

  • PDF

Performance Verification of Gas Insulated Switchgear using UHF Partial Discharge Diagnosis Method (UHF법 부분방전 진단기법에 의한 가스절연 개폐장치의 성능검증)

  • Kim, J.S.;Park, K.S.;Song, Y.P.;Kim, D.K.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.37-39
    • /
    • 2002
  • UHF method is very effective to diagnosis for partial discharge of GIS. In generally, inner UHF sensor can be attached on sheath cover of GIS under construction for periodic inspection. However, there is no inner UHF sensor for GIS of the domestic substation. We used the outer UHF sensor attached on spacer for GIS of existing substation. In this paper, we report the diagnosis result of partial discharge on 800kV GIS in domestic substation. From these results, we can find the quantity, reason and location of PD and certificate the performance of UHF method for partial discharge diagnosis of GIS.

  • PDF

Insulation Performance and BOR of Pressurized Large-capacity Liquid Hydrogen Storage Tank (가압식 대용량 액체수소 저장탱크의 단열 성능과 BOR)

  • HEUNG SEOK SEO;YEONGBUM LEE;DONGHYUK KIM;CHANGWON PARK
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.6
    • /
    • pp.650-656
    • /
    • 2023
  • In order to efficiently control boil-off rate of a liquefied hydrogen tank, the important thing is to maintain an appropriate vacuum level. however, compared to small and medium-sized storage tank, it is very difficult to create and maintain vacuum in large-capacity storage tanks. In this study, we aim to determine the target level of future large-capacity storage tank technology development and secure basic data on performance test methods by analyzing the corelation between evaporation gas and thermal conductivity of liquefied hydrogen storage tanks.

A study on the applicability of augmented proportional navigation guidance

  • Imado, Fumiaki;Ichikawa, Akira;Kanai, Kimio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.468-473
    • /
    • 1993
  • Augmented proportional navigation requires the information of a target acceleration, which must be estimated by a filtering logic. The process necessary accompanies a time lag, which degrades the guidance performance. A trade-off study between augmented and conventional proportional navigation is conducted with the time lag taken into consideration. The result shows that the conventional proportional navigation has better performance against a target maneuver in the missile-target coplane, while the augmented has better performance against out-of-coplane maneuver.

  • PDF

A Study on the Effect of Performance on Employer's Satisfaction of Service Company (서비스 기업의 종업원 만족도가 경영성과에 미치는 영향에 관한 연구)

  • Park, Jung-sub
    • Journal of Distribution Science
    • /
    • v.3 no.2
    • /
    • pp.101-119
    • /
    • 2005
  • For the customer satisfaction, the inside customer satisfaction must be made by offering the service of a good quality to the inside customer. If the inside customer is not satisfied with own business, the achievement of customer's loyalty & customer satisfaction which have direct effects on the performance of a corporation, comes to be difficult. This study tries to analyze what effect the inside customer satisfaction has on the yield performance of a corporation on the subject of the salespersons of the direct-control store among the retail store business.

  • PDF

Evaluation of Performance of Protective Surface Coating for Concrete

  • Ahn, Tae Song;Cheong, Hai Moon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1061-1066
    • /
    • 2003
  • Chloride penetration into concrete is the main cause of the steel corrosion in concrete structures exposed to chloride-rich environments. Protective surface coatings are increasingly being applied to concrete structures to reduce chloride penetration. In this study, the performance of various surface coatings was evaluated. Most coatings showed good results for the various tests of the performance evaluation. Surface coatings can delay deterioration such as chloride-induced reinforcing bar corrosion effectively.

  • PDF

Testing Items Change on Characteristics of Protective relays (보호계전기 특성시험기술의 시험항목 변화)

  • Jang, Byung-Tae;Lee, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.161-162
    • /
    • 2008
  • The steady state performance test for the digital protective relay using general relay test equipment has been main test methods. Because of the development of advanced power system testing equipments, dynamic performance test has been carried out additionally using a digital simulator such as RTDS(Real Time Digital Simulator). For the case of newly adopted digital protective relay with IEC 61850 and network, performance testing items need supplementing. This report displays testing items change according to newly protective relay.

  • PDF