• Title/Summary/Keyword: Corporation Concentration

Search Result 799, Processing Time 0.026 seconds

A Study on the Ozone Consumption Rate for Drinking Water Treatment Process with Ozone Application (오존의 정수처리 적용을 위한 오존소비인자에 관한 연구)

  • Kang, Tae-Hee;Oh, Byung-Soo;Kwon, Soon-Buhm;Sohn, Byeong-Yong;Kang, Joon-Wun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.663-669
    • /
    • 2005
  • The aim of this study was to investigate the ozone decay pattern for the effective application of ozone in drinking water treatment. In order to measure the ozone decomposition in water, ozone measuring instrument was developed with flow injection analysis (FIA) method. From the result of continuous residual ozone concentration in water, it was confirmed that the ozone decay pattern was divided with instantaneous ozone demand(I.D) and pseudo first-order rate($k_c$) phases, which were influenced by the variation of ozone dose. The empirical model obtained from I.D and $k_c$ values enabled us to predict the residual ozone concentration according to the reaction time, showing the high correlation between model and experimental values. The concentration of OH radical and $R__{ct}$ could be indirectly measured by OH radical probe compound. In both I.D and $k_c$ phases, the production pattern of OH radical could be observed, which was also affected by the variation of ozone dose. Finally, it was confirmed that the ozone consumption rate was varied according to the each drinking water treatment process and seasoning. Therefore, the optimum position and dosage of ozone have to be selected by considering various factors.

Assessment of Biochemical Efficiency for the Reduction of Heavy Metal and Oil Contaminants in Contaminated Soils (토양내 중금속 및 유류 오염농도 저감을 위한 생화학적 기작의 효율성 평가)

  • Kim, Man-Il;Jeong, Gyo-Cheol;Kim, Eul-Young
    • The Journal of Engineering Geology
    • /
    • v.22 no.3
    • /
    • pp.253-262
    • /
    • 2012
  • With the aim of remediating soils contaminated by heavy metals and oil, experimental research was conducted to evaluate the optimal design factors for remediation in terms of efficient soil washing methods and processes. The experiments employed absorptiometric analysis and gas chromatography methods to reduce the concentration of heavy metals such as cooper (Cu), lead (Pb), and zinc (Zn), and total petroleum hydrocarbons (TPH) in contaminated soils. The experimental processes consisted of deciding on the washing solution, washing time, and dilution ratio for contaminated soils. A dissolution analysis of heavy metals was then performed by the addition of surfactant, based on the results of the decision experiments, and the injection processes of microbes and hydrogen peroxide were selected. The experimental results revealed that reduction effects in contaminated soils under the experimental conditions were most efficient with hydrochloric acid 0.1 mole, washing time 1 hour, and dilution ratio 1:3, individually. Additional reduction effects for heavy metals and TPH were found with the addition of a washing solution of 1% of surfactant. The addition of microbes and hydrogen peroxide caused a reduction in TPH concentration.

Multi-stage Process Study of PEI-PDMS Hollow Fiber Composite Membrane Modules for $H_2/CO_2$ Mixed Gas Separation ($H_2/CO_2$ 혼합기체의 분리를 위한 PEI-PDMS 중공사 복합막 모듈의 다단 공정 연구)

  • Lee, Chung Seop;Cho, Eun Hye;Ha, Seong Yong;Chung, Jong Tae;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Poly(ether imide) (PEI)-poly(dimethylsioxane) (PDMS) composite membranes and their modules were prepared, which are capable of selective $CO_2$ separation from the mixture gas. The gas flow rate, concentration, recovery ratio of $H_2$ and removal ratio of $CO_2$ outflowing by stage-cut were characterized at $25^{\circ}C$ and the constant pressure. In addition, to increase the recovery ratio of $H_2$, one stage, two stage series connection, and three stages series + parallel connection tests were carried out. When the stage-cut was 0.32 for the three stages connection operation, the concentration $H_2$ of the produced gas and the recovery ratio of $H_2$ was 97% and 85%, respectively. And also the removal ratio of $CO_2$ was 90% was obtained and the recycled gas concentration was similar with that of the feed gases.

Effect of Lactic Acid Bacteria Powder on Loperamide-induced Constipation in Rat (Loperamide로 유도된 변비 증상에 유산균 제제가 미치는 영향)

  • Kim, Eun Young;Jo, Kyungae;Ahn, So Hyun;Park, Sung Sun;Son, Heung Soo;Han, Sung Hee
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.6
    • /
    • pp.956-964
    • /
    • 2015
  • Probiotics is known improve the microenvironment of colon; however, the metagenomic DNA study of its lactic acid bacteria in constipation induced by loperamide is not clearly understood. In the present study, we investigated the reduction of the lactic acid bacteria in case of constipation, in normal and loperamide-induced rat. Lactic acid powder (lactic acid bacteria 19) was prepared from Chong Kun Dang Pharmaceutical Corporation. After 2 weeks of oral administration, the group treated with the higher concentration of lactic acid bacteria ($10^9CFU/mL$ per kg of body weight) following loperamide treatment was the most effective in increasing number, weight, and water content of feces. A similar but significant increase was found in the group treated with lower concentration of lactic acid bacteria ($10^7CFU/mL$ per kg of body weight) after loperamide treatment. The concentrations of acetic acid and propionic acid in feces in the loperamide-induced rat with high concentration lactic acid, were significantly higher than that of others. Furthermore, gastrointestinal transit ratio as well as the length and area of intestinal mucosa were significantly increased after treatment with lactic acid bacteria in loperamide-induced rat. Metagenomics DNA analysis indicated that the microorganism homology in cecum was similar between the groups of normal (NOR) and HIG. Our results show that lactic acid bacteria were effective in improving the constipation.

Antioxidant, Anti-inflammation, and Anti-aging Effects of Ethyl Acetate Fraction from Cynanchum paniculatum Extracts (산해박 분획물의 항산화, 항염증 및 항노화 활성 효과 연구)

  • Jae Yong Seo;Go Eun Kim;Ji Soo Ryu;A Reum Jang;Su An Sim;Jung No Lee;Seunghee Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.1
    • /
    • pp.85-93
    • /
    • 2024
  • In this study, we prepared fractions from Cynanchum paniculatum (C. paniculatum) with ethyl acetate and identified the structure and content of paeonol, an indicator substance. Fractions were obtained by sequential solvent fractions using n-hexane, methylene chloride, ethyl acetate, n-butanol, and distilled water, and showed the highest paeonol content in ethyl acetate (EtOAc). The structure of the ethyl acetate fraction (EA) was confirmed by nuclear magnetic resonance (NMR) and the content was determined by high performance liquid chromatography (HPLC) analysis. The antioxidant activity of EA was tested through its ability to scavenge 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS), and its ability to inhibit nitric oxide (NO) production in RAW 264.7 cells induced by lipopolysaccharide (LPS) was tested for its ability to inhibit NO production in a concentration-dependent manner. Furthermore, MMP-1 production induced by ultraviolet B (UVB) was decreased in a concentration-dependent manner by the EA, and the ability to produce procollagen type-I was increased in a concentration-dependent manner. In addition, as a result of conducting clinical trials using cosmetic formulations containing EA, the effect of improving wrinkles around the eyes was confirmed. Thus, it is expected that Cynanchum paniculatum can be used as a natural functional cosmetic material with antioxidant and anti-aging effects.

Stress Reducing Method in the Connection Area with Pier due to the Torsion of the Girder of Fish-bone Type Bridge (경골형 교량거더의 비틀림에 의한 말뚝연결부 응력저감기법)

  • Kim, Jae-Heong;Yun, Kyung-Min;Yoon, Ki-Yong;Lee, Chin-Ok;Lim, Nam-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2399-2405
    • /
    • 2014
  • A fish-bone type bridge is vulnerable to the torsional behavior due to the single girder system with planar zigzag conformation. The fixed connecting area between the girder and pier is the special weak point because the torsional load creates excessive stress concentration. Therefore, the method to reduce the stress concentration is required. In this study, the reduction efficiency of various reinforcing types to reduce the excessive stress occurring at the connecting area is evaluated by using numerical analyses.

Leaching Characteristics of Unregulated Heavy Metals in Specified Wastes (지정폐기물 중 미규제 중금속류의 용출 특성)

  • Jeon, Tae-Wan;Shin, Sun-Kyoung;Lee, Jeong-Ah;Kim, Hyoung-Seop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.213-217
    • /
    • 2008
  • The objective of this research is to investigate the leaching characteristics of unregulated heavy metals such as Ni, Zn, Ba, Be, Sb, Se, V in specified waste. 108 waste samples which were taken from the representative facilities emitting hazardous substances, were analyzed. The rate of leaching of heavy metal was measured using an official test method. From the results, wastewater treatment sludge and dust contained much Ni, and Zn was detected in all samples. Dust and waste catalyst producted from petroleum-refining process tended to reveal V in high concentration. Ba, Be, Sb, Se showed low concentration, but require additional analyses of waste generated at different industries.

A Sensitivity Analysis of the OZIPR Modeling Result for the Seoul Metropolitan Area (OZIPR 모델링 결과의 민감도 분석)

  • Lee, Sun-Hwa;Jin, Lan;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.7 no.3
    • /
    • pp.99-108
    • /
    • 2011
  • To establish area specific control strategies for the reduction of the ozone concentration, the Ozone Isopleth Plotting Package for Research(OZIPR) model has been widely used. However, the model results tend to changed by various input parameters such as the background concentration, emission amount of NOx and volatile organic compounds (VOCs), and meteorological condition. Thus, sensitivity analysis should be required to ensure the reliability of the result. The OZIPR modeling results for five local government districts in the Seoul Metropolitan Area (SMA) in June 2000 were used for the sensitivity analysis. The sensitivity analysis result showed that the modeling result of the SMA being VOC-limited region be still valid for a wide range of input parameters' variation. The estimated ozone concentrations were positively related with the initial VOCs concentrations while were negatively related with the initial NOx concentrations. But, the degree of the variations at each local district was different suggesting area specific characteristics being also important. Among the five local governments, Suwon was chosen to identify other variance through the period from April to September in 2000. The monthly modeling results show different ozone values, but still showing the characteristics of VOCs-limited region. Limitations due to not considering long range transport and transfer from neighbor area, limitation of input data, error between observed data and estimated data are all discussed.

Effect of Dissolved Oxygen (DO) on Internal Corrosion of Water Pipes

  • Jung, Hae-Ryong;Kim, Un-Ji;Seo, Gyu-Tae;Lee, Hyun-Dong;Lee, Chun-Sik
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.195-199
    • /
    • 2009
  • A series of laboratory-scale corrosion experiments was carried out to observe the effect of dissolved oxygen (DO) in the presence of other water quality parameters, such as hardness, Cl-, and pH using various pipe materials. In addition, a simulated loop system was installed at a water treatment plant for pilot-scale experiment. Laboratory-scale experiment showed that corrosion rates for galvanized steel pipe (GSP), carbon steel pipe (CSP), and ductile cast iron pipe (DCIP) were decreased to 72%, 75%, and 91% by reducing DO concentration from 9${\pm}$0.5 mg/L to 2${\pm}$0.5 mg/L. From the pilot scale experiment, it was further identified that the average ionization rate of zinc in GSP decreased from 0.00533 to 0.00078 mg/$cm^2$/d by controlling the concentration of DO. The reduction of average ionization rate for copper pipe (CP) and stainless steel pipe (SSP) were 71.4% for Cu and 63.5% for Fe, respectively. From this study, it was concluded that DO could be used as a major parameter in controlling the corrosion of water pipes.

Concentration of Serum Cholesterol and Triglyceride in Health Checkup Groups at Life Transition Periods (40 Years Old and 66 Years Old) in Partial Area of Korea (일부지역 생애전환기 건강대상자들의 혈청 총콜레스테롤과 중성지질농도 비교 -40세와 66세를 대상으로-)

  • Shin, Hyun-Gyu;Na, Young-Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.2
    • /
    • pp.92-96
    • /
    • 2010
  • The National Health Insurance Corporation (NHIC) was performed population health checkup survey program with especially two target ages, 40 years and 66 years old that were called as "life transition period" for national collective prophylaxis of cardiovascular diseases in Korea. We were investigated and compared between two age groups with the serum levels of cholesterol and triglyceride from data of the survey in Daegu province, Korea at April, 2007. Data of one hundred persons per each age (40 years and 66 years old) were collected and investigated for risk factors for chronic degenerative diseases including serum lipid concentration, health habits of drinking, smoking, exercise etc. In spite of the definite difference of life transition of the each age, the transition from adolescence to adulthood at 40 years old, and from adulthood to senescence at 66 years old, there were no significant difference of total cholesterol and triglyceride between two age groups.

  • PDF