• Title/Summary/Keyword: Corona test

Search Result 132, Processing Time 0.024 seconds

TOWARD A NEXT GENERATION SOLAR CORONAGRAPH: DIFFRACTED LIGHT SIMULATION AND TEST RESULTS FOR A CONE OCCULTER WITH TAPERED SURFACE

  • Yang, Heesu;Bong, Su-Chan;Cho, Kyung-Suk;Choi, Seonghwan;Park, Jongyeob;Kim, Jihun;Baek, Ji-Hye;Nah, Jakyoung;Sun, Mingzhe;Gong, Qian
    • Journal of The Korean Astronomical Society
    • /
    • v.51 no.2
    • /
    • pp.27-36
    • /
    • 2018
  • In a solar coronagraph, the most important component is an occulter to block the direct light from the disk of the sun. Because the intensity of the solar outer corona is $10^{-6}$ to $10^{-10}$ times of that of the solar disk ($I_{\odot}$), it is necessary to minimize scattering at the optical elements and diffraction at the occulter. Using a Fourier optic simulation and a stray light test, we investigated the performance of a compact coronagraph that uses an external truncated-cone occulter without an internal occulter and Lyot stop. In the simulation, the diffracted light was minimized to the order of $7.6{\times}10^{-10}I_{\odot}$ when the cone angle ${\theta}_c$ was about $0.39^{\circ}$. The performance of the cone occulter was then tested by experiment. The level of the diffracted light reached the order of $6{\times}10^{-9}I_{\odot}$ at ${\theta}_c=0.40^{\circ}$. This is sufficient to observe the outer corona without additional optical elements such as a Lyot stop or inner occulter. We also found the manufacturing tolerance of the cone angle to be $0.05^{\circ}$, the lateral alignment tolerance was $45{\mu}m$, and the angular alignment tolerance was $0.043^{\circ}$. Our results suggest that the physical size of coronagraphs can be shortened significantly by using a cone occulter.

Discharge Characteristics between Needle and Plane Electrodes in Water under Impulse Voltages (임펄스전압에 의한 침 대 평판전극에서 수중방전특성)

  • Choi, Jong-Hyuk;Park, Geon-Hun;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.67-74
    • /
    • 2008
  • In this paper we describe discharge characteristics between needle-to-plane electrodes in water in various conditions such as different impulse voltages, polarities and water resistivities. Streamer corona is initiated at the tip of needle electrode and propagates toward plane electrode, and it experiences the final jump across the test gap. The branched channels of streamer coronas for lower water resistivities are much thicker and brighter than those for higher water resistivities at the same level of applied voltage. The negative streamer coronas not only have more branches but also widely spread out compared to the positive streamer coronas. A number of pulse-like currents ranging from some hundreds mA to a few A after streamer corona onset were produced with discharge developments. The time-lags-to breakdown for the positive polarity were remarkably shorter than those for the negative polarity. The pre-breakdown energy supplied into the test gap was inversely proportional to water resistivity.

Preparation of PDMS Surface Modifier Using Silane-Functionalized Polymer Precursor Manufacture and Their Properties (실란 기능화 아크릴 고분자 전구체를 이용한 PDMS 표면 개질제 제조 및 표면 물성)

  • Shin, Jae-Hyeon;Kim, Nahae;Kim, Juyoung
    • Journal of Adhesion and Interface
    • /
    • v.19 no.4
    • /
    • pp.154-162
    • /
    • 2018
  • Plasma treatment and corona treatment have been used for surface modification of polydimethylsiloxane (PDMS) film by activating its surface with the -OH group. Adhesion promoter or coupling agent was also used to improve adhesion of PDMS film with various materials. However, obtained hydrophilicity onto the surface of PDMS films with those processes was transient and vulnerable. In this study, a new alkoxysilane-functionalized acrylic polymer precursor was first synthesized by copolymerization process, and then was reacted with HO-terminated PDMS through condensation reaction to prepare a new surface modifier for PDMS film. The structure and molecular weight of the prepared surface modifier were confirmed by 1H-NMR and GPC measurement. Surface properties of surface modifier-coated PDMS films were also investigated by using XPS, ATR and WCA analysis. The adhesion between the PDMS film and the surface modifier was tested using cross-cut test.

Development and Its Characterization of Earth Plate for Early Streamer Discharge (조기방전용 접지판의 개발 및 특성)

  • Choi, Sang-Won;Her, Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.46-48
    • /
    • 2014
  • This paper compared and demonstrated the performance of the earth plate for conventional type and early streamer discharging type developed a new plate in order to improve the performance of the ground plate for use in grounding. The results obtained are shown below; early streamer discharge earth plate was high 5 kV on DC flashover voltage and corona discharge current was higher than about 2 times under the same test conditions compared to the conventional earth plate. From the experiential result, streamer discharge earth plate had a function of rapid inflow/out flow than the general ground plane because of by corona discharge current to be generated in the sharp serrated in formed the ground plane when strike current occurred. In the future, the newly developed early streamer discharge ground plate would be beneficial for grounding work to be widely used to promote the convenience and economy of construction.

Analysis on the Degradation of Insulators using Corona Camera (코로나 카메라를 이용한 불량애자 검출사례 분석)

  • Kim, H.S.;Kim, P.H.;You, Y.K.;Koo, K.W.;Kim, H.J.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.132-134
    • /
    • 2003
  • Insulator that is used in electric power equipment superannuation and being damaged disorder can. Such as defected insulator has repair or change must because defective influence in electrical equipment. There are many method developed for detecting the defected insulators, analyzed various test of devide voltage, electric field, ultrasonic and discharge pulse. But methods of detecting ultrasonic of discharge, electric field or leakage current could not application in the field, In this paper, we compare the advantage and the limitation of the method to detect defected insulator, and wish proposed using corona camera.

  • PDF

Evaluation of Endothelial Cell Attachment on Polymer Surface (고분자 표면의 혈관내피세포 부착력에 관한 연구)

  • Choi, Jin-Wook;Ryu, Gyu-Ha;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.131-140
    • /
    • 1990
  • To improve antithrombogenicity of polymer that used in vascular graft and artificial organs, seeding of human endothelial cells on the polyurethane was studied. Human endothelial cells were ismlated from human umbilical veins, using type I collagenase, and identified with goat anti vWF antibodies. Human endothilial cell seeding was tried upon the polyurethane which has good mechanical property and resists stresses. The hydrophobic polyurethane surface was changed hydrophilic by corona discharf:e treatment. Surface hydrophilicity was measured with Wilhemly plate method and the goniometer. To evaluate matrix protein adsorption, fibronectin adsorption test was done. To eveluate cell adhesion, human endothelial cell attachment forces were measured rising a perfusion chamber of , ism diamter. Less cells were detached from the hydrophilically treated polyurethane. This showed that corona discharge on the polyurethane could improve matrix adsorption and endothelial cell attachment.

  • PDF

Treeing Phenomena in the Home-made Solid Organic Insulating Materials (국산유기절연재료의 Treeing현상)

  • 성영권;이헌용;이계호;유기한
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.57-65
    • /
    • 1977
  • In roder to investigate the influence of treeing on electric breakdown of solid organic insulator the initiation and growing mechanism of tree itself, and the correlation between corona discharge and treeing phenomena in solid orgainc insulating materials, several experiments were carried out by means of needle test on polymethyl-methacrylate. The obtained results showed that the existence of voids in specimen had important effects on initiation voltage of trees and, when the direct voltage was applied, the initiation voltage of trees increased by space charge effect. And also the stagnation phenomena due to the transfer of vacancy cluster or polymekr cage in specimen might beconsidered in process of growth of trees, and corona discharge seemed to be the pre-phenomena of treeing because trees were normally initiated by internal discharge in voids.

  • PDF

Effects of Particle Size of $Al(OH)_3$ on the Electrical Properties of Silicone Rubber ($Al(OH)_3$의 입자크기에 따른 실리콘 고무의 전기적 특성 연구)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Na, Moon-Kyong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1936-1938
    • /
    • 2005
  • $Al(OH)_3$ is added to the silicone rubber for improvement of its resistance against surface discharge. In this paper, four kinds of $Al(OH)_3$ were added to the SIR during compounding. SIR was deteriorated by a corona treatment. Hydrophobicity recovery rate after corona treatment and arc resistance of SIR were investigated. Hydrophobicity recovery rate of SIR was evaluated by the measurement of contact angle. Arc resistance was evaluated by measuring weight loss of SIR after arc resistance test.

  • PDF

Comparison of the Poor Insulator Detecting Technique for the Reliability Enhancement of the Electric Power Facilities (전력설비의 신뢰성 향상을 위한 불량애자검출기법의 비교)

  • Jung, Soon-Won;Koo, Kyung-Wan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.417-423
    • /
    • 2008
  • For the evaluation in the safety of outdoor insulator, there are various methods such as: visual observation; voltage measurement; use of ultrasonic wave due to partial discharge; electric field measurement; use of infrared/ultraviolet sensor-type camera. However, many problems have been issued regrading the reliability of the evaluation test and safety of testing operation. Accordingly, the present study has investigated and analyzed the characteristics and mechanisms of the insulator deterioration, in order to obtain an optimal method for detecting poor insulator so that the reliability of power facilities can be enhanced. Besides, based on theoretical analysis of domestic and international detection methods for poor insulator, the reliability has been compared and evaluated quantitatively. As a result, it was shown that the corona camera would be the best choice for domestic workplace application in detecting poor insulator for enhancing the reliability of power transmission line.

2019 Total Solar Eclipse Expedition of KASI

  • Bong, Su-Chan;Yang, Heesu;Lee, Jae-Ok;Kim, Jinhyun;Jeon, Young-Beom;Jang, Bi-Ho;Seough, Jungjoon;Park, Young-Deuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.69.2-69.2
    • /
    • 2020
  • Korea Astronomy and Space Science Institute (KASI) is developing a coronagraph to measure the coronal electron density, temperature, and speed utilizing spectral change of the K-corona around 400 nm. However, near UV light is more affected by atmospheric effect on the ground than visible light. For the total solar eclipse on July 2 2019, KASI organized an expedition team to test the possibility of the similar measurement scheme in the visible light. The observation site was in Las Flores, San Juan, Argentina. We built an imaging spectrograph using micro lenslet array and grism, named Coronal Integral Field Spectrograph (CorIFS). In addition, images of white light corona, wide field background, and all sky were taken with various camera settings. We present the preliminary results of the expedition.

  • PDF