• 제목/요약/키워드: Corona test

검색결과 132건 처리시간 0.031초

변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구 (A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area)

  • 민문기;이재기;박진엽;김희제
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발 (Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line)

  • 길경석;양광호;이성두;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.

전극 구조에 따른 코로나 방전의 주파수 스펙트럼 분석 (Frequency Spectrum Analysis of Corona Discharge as Electrode Structures)

  • 정광석;김선재;박대원;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.118-118
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves which is generated by corona discharges as a basic study to develop a on-line diagnostic technique for power facilities installed in a closed-switchboard. Five types of electrode system were arranged to simulate corona discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. These results showed that the frequency spectrum of corona discharges exists widely in ranges from 30 to 1,000 [MHz].

  • PDF

방사전자파의 주파수분석에 의한 배전반 진단기술 (Diagnostic Technique of a Switchboard by Frequency Analysis of Radiated Electromagnetic Wave)

  • 박대원;김선재;정광석;길경석;조은제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.41-45
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves generated by series arc- and corona- discharges as a basic study to develop an online diagnostic technique for power facilities installed inside switchboards. To simulate corona and series arc discharges, an arc generator specified in UL1699 and a corona generator were fabricated. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. The frequency spectrum exists in ranges from 30 to 500 [MHz] for series arc discharge and 30 [MHz] to 2 [GHz] depending on defects for corona discharge. The peak frequency of series arc discharge and corona were 40 [MHz], 80 [MHz] and 35 [MHz]~160 [MHz], respectively.

  • PDF

코로나 잡음 특성을 고려한 초고압 송전선의 다중도체배열방식 연구 (A Study on Multi-conductor Bundle for EHV Transmission Line Considering Corona Noise Characteristics)

  • 민석원;박종근
    • 대한전기학회논문지
    • /
    • 제39권5호
    • /
    • pp.508-515
    • /
    • 1990
  • This paper describes the corona characteristics of conductor bundle for EHV transmission line. To reduce the corona noise, the asymmetric conductor bundle to minimize the electric field of the conductor surface is proposed. The charge simulation method is used to formulate the electric field of conductor surface and the optimal arrangement of subconductor to minimize it is selected to apply the nonlinear successive quadratic programming. Through the analytical comparison and the corona cage test, it is proved that the asymmetric conductor bundle proposed in this paper can reduce the average maximum electric field of the phase conductors and the corona noise more than the conventional symmetric conductor bundle and asymmetric conductor bundle by GE.

  • PDF

Corona방전에 의한 유전체의 열화현상 (The Deterioration Phenomena for Dielectrics Causing Corona Discharge)

  • 성영권;백영학;차균현
    • 전기의세계
    • /
    • 제19권6호
    • /
    • pp.18-25
    • /
    • 1970
  • The object of this project is to manifest the mechanism of deterioration phenomena for dielectrics causing corona discharge and applies it for determine the standard corona detection technique. As the results, we observed that corona discharges may occur more strongly around cylindrical shape electrode in air than hemisphere shape electrode in vacuum, so that it depends on effects such as shape of the electrode, moisture, surface coditions, etc. According to observed the deterioration of dielectrics takes place in following stages. At first the attacked surface by an electron avalanche is uniformly eroded; then pits are formed; after that sharp channels are formed which lead to break-down as a treeing. The test are accelerated with higher frequencies by the cylindrical bar shape electrode in the pulse stright detection method more sensitive than Lissajous patterns. Lissajous patterns detection method is simple but usually insensitive and has disadvantage that the magnitude of the individual discharge is not measured.

  • PDF

코로나 확진자 수 예측을 위한 BI-LSTM과 GRU 알고리즘의 성능 비교 분석 (Comparative analysis of performance of BI-LSTM and GRU algorithm for predicting the number of Covid-19 confirmed cases)

  • 김재호;김장영
    • 한국정보통신학회논문지
    • /
    • 제26권2호
    • /
    • pp.187-192
    • /
    • 2022
  • 위드 코로나의 예정 발표일이 결정되었고, 위드 코로나에 가장 중요한 조건인 백신 접종을 아직 부작용 걱정 때문에 완료하지 않은 사람들이 있다. 또한 위드 코로나로 경제는 회복될 수 있지만 감염자 수는 급증할 수 있다. 본 논문은 위드 코로나에 앞서 코로나19에 대한 경각심을 깨우고자, 코로나19를 비선형 확률과정으로 예측한다. 여기서 딥러닝의 RNN중 양방향 LSTM인 BI-LSTM와 LSTM보다 gate수를 줄인 GRU를 사용하고 이것을 train set, test set, 손실함수, 잔차분석, 정규분포, 자기 상관을 통해서 비교 분석하여 어떠한 성능이 더 좋은지 비교하고 예측한다.

Motor Function Recovery in Stroke Patients with Corona Radiata Infarct: 4 Case Studies

  • Kim, Chung-Sun;Kwon, Jung-Won
    • The Journal of Korean Physical Therapy
    • /
    • 제22권3호
    • /
    • pp.31-35
    • /
    • 2010
  • Purpose: The aim of this study was to use fMRI and clinical prognosis criteria to evaluate therapeutic interventions in stroke patients with corona radiata infarct and acquire fundamental information about recovery mechanisms. Methods: Four subjects (2 men, 2 women) who had strokes with corona radiata infarct were recruited. For all subjects, motor functions such as motricity index (MI), modified brunnstrom classification (MBC), functional ambulatory category (FAC), and bathel index (BI) were evaluated. Evaluations were done at least 4 times over a period of approximately 6~7 months from stroke onset. We compared the final evaluation with the first. Results: All patients with corona radiata infarct showed improvement in motor outcomes with the passing of time. The strength of all patients improved from zero or trace levels to normal or good levels in the MI (Motricity Index) test. Other motor outcomes including the modified brunnstrom classification (MBC), the functional ambulatory category (FAC), and the bathel index (BI) also improved with the passing of time. Conclusion: Stroke patients with corona radiata infarcts change for the better over time. Therefore, one can introduce clinical interventions by the aspect of progress in functional motor recovery.

765kV 실규모 실증시험장 건설 (The construction or 765kV test line)

  • 조성배;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.431-434
    • /
    • 1991
  • To develop the EHV transmission technology, the electrical environment problems such as Audible Noise etc. have been studied by the use of Corona Cage with artifical water spray equipment. However, this study has difficulties in simulating the amount of natural conditions. Therefore, We will plan to install full scale EHV test line to prove the measuring values of Corona Noise, and to selection of Conductors, Insulators, and to economical design, construction data.

  • PDF

RTV 실리콘 코팅재의 전기적 열화 특성 연구 (Study on electrical ageing properties of ATV silicone coatings)

  • 한세원;조한구;한동희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.35-39
    • /
    • 2003
  • An ageing characteristics of RTV coating materials by corona discharge have been studied. The recovery of a hydrophobicity of RTV coating materials with the thickness of $300{\mu}m$ was in identical with a bulk silicone materials. The hydrophobicity of RTV coating materials has been almost lost when its were discharged during 40 seconds by corona with 10kV, and recovered after about 45 hours. But the resistivity of RTV coating materials has not been recovered after 45 hours, even though after 80 hours the 95% of initiation resistivity value has been recovered. There was no critical compounds(such as Si and Al) changes on RTV surfaces by the corona discharge treatment until 100 seconds. In the test of arc erosion, it was seen that the coating sample with silicone rubber as a base material have more longer bum-out time than other samples with FRP or glass base.

  • PDF