• Title/Summary/Keyword: Copper removal

Search Result 330, Processing Time 0.018 seconds

Effect of Operating Parameters on the Removal Performance of Copper Ion by Electrodialysis (전기투석을 이용한 구리이온의 제거 시 운전인자의 영향)

  • Jung, Hyo-Sang;Lee, Gangchoon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • To evaluate the feasibility of electrodialysis for copper removal from industrial wastewater, the effect of operating parameters on the removal of copper was experimentally estimated. The limiting current density (LCD) linearly increased with the copper concentration and the flow rate. The time when the copper concentration of diluate reaches to 3 mg/L was linearly proportional to initial concentration of diluate, and the concentration of concentrate did not affect the removal rate. Increase in the flow rate gave a positive effect on the removal rate and became insignificant at flow rates greater than 2.4 L/min. The removal rate increased with the applied voltage. From the operation of the electrodialysis module used in this research, the flow rate of 2.4 L/min and the voltage corresponding to the 80~90% of LCD were found be the optimum operating condition for the copper removal from highly concentrated copper solutions.

Surface Modification of Silica Spheres for Copper Removal

  • Kim, Byoung-Ju;Park, Eun-Hye;Kang, Kwang-Sun
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.5
    • /
    • pp.317-320
    • /
    • 2016
  • Efficient copper removal from water was achieved by using surface modified silica spheres with 3-mercaptopropyltrimethoxysilane (MPTMS) using base catalyst. The surface modification of silica spheres was performed by hydrolysis and condensation reactions of the MPTMS. The characteristic infrared absorption peaks at 2929, 1454, and 1343 cm−1 represent the −CH2 stretching vibration, asymmetric deformation, and deformation, respectively. The absorption peaks at 2580 and 693 cm−1 corresponding the −SH stretching vibration and the C-S stretching vibration indicate the incorporation of MPTMS to the surface of silica spheres. Field emission scanning electron microscope (FESEM) image of the surface modified silica sphere (SMSS) shows nano-particles of MPTMS on the surface of silica spheres. High concentration of copper solution (1000 ppm) was used to test the copper removal efficiency and uptake capacity. The FESEM image of SMSS treated with the copper solution shows large number of copper lumps on the surface of SMSS. The copper concentration drastically decreased with increasing the amount of SMSS. The residual copper concentrations were analyzed using inductively coupled plasma mass spectrometer. The copper removal efficiency and uptake capacity with 1000 ppm of copper solution were 99.99 % and 125 mg/g, respectively.

The Removal of Heavy Metals from Treated Wood by Biological Methods(I) - Removal of Copper from CCA, CCFZ Treated Wood - (생물학적인 방법을 이용한 방부처리재의 중금속 제거(I) - CCA 및 CCFZ처리재에서 구리의 제거 -)

  • Son, Dong-Won;Lee, Dong-heub;Kang, Chang-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.151-157
    • /
    • 2002
  • The removing copper from CCA, CCFZ treated wood were tested with Tyromyces palustris. The shacking culture, solid culture, and stationary culture methods were tested to removal of copper in CCA, CCFZ treated wood. The steam pressure method and oxalic acid method were tested as pretreatment. To investigate of copper removal mechanism, the oxalic acid that produced by T. palustris and combination with copper was examined on stationary culture that contained CCA and CCFZ treated wood chips. Oxalic acid increased copper removing rate of T. palustris as pretreatment. Stationary culture had most removal effectiveness among the culturing methods. The removal rate of copper on bioreactor was 61% on 7 days. Copper-oxalate was detected on liquid culture, which show the oxalate from liquid of culture combined with copper from treated wood. It would be related to the removal of copper from treated wood by T. palustris.

Synthesis of Removal Agent and Developement of Treatment Technology on Copper (효과적인 구리 제거제 합성 및 처리 기술 개발에 관하여)

  • Cho, Byeung-Rak
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.2
    • /
    • pp.35-39
    • /
    • 2013
  • This paper synthesized the new copper removal agent(PW-2001) and investigated removal efficiency of copper, COD, calcium, SS and sludge amounts. Removal efficiency of copper were 96.1% and 99.1% with the lime and PW-2001, respectively while COD removals reached up to 38% and 69.6% with the use of lime and PW-2001. The concentrations of calcium and SS with PW-2001 were decreased 2.68 and 4.95 times lower than those with lime. Amount of sludge with PW-2001 was 60% smaller than lime. Quantity of PW-2001 needed for coagulation only reached 58.7, compared to lime standard quantity(100), and total cost of copper removal with PW-2001 was saved 25% more than lime.

Phosphorus Removal by Aluminium Ion Generated with the Pitting Corrosion of Aluminium (알루미늄의 부식으로 발생한 알루미늄 이온에 의한 인 제거)

  • Cheong Kyung-Hoon;Jung Oh-Jin
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.705-710
    • /
    • 1999
  • The fundamental experiments on the phosphorus removal from water were carried out by the batch and continuous reactors which used aluminium and copper plate. In this systems, the phosphorus was removed by aluminium ion generated with the electrochemical interaction (pitting corrosion) of aluminium and copper. In the batch experiments, the efficiencies of phosphorus removal increased when the surfaces of aluminium and copper plate were brushed. The phosphorus removal by aluminium ion was affected the copper plate and NaCI in this system. The optimal pH values were 5 and 6 for the phosphorus removal. The efficiency of phosphorus removal increased with increasing NaCI concentration, surface area of aluminium and copper plate. The $CUSO_4{\cdot}5H_2O$ instead of copper plate could be used as Cu source. The effluent $PO_4-P$ concentration as low as 2 $mg/{\ell}$ could have been obtained during the continuous experiment at HRT of 48 hrs.

  • PDF

Simultaneous Removal of Cadmium and Copper from a Binary Solution by Cathodic Deposition Using a Spiral-Wound Woven Wire Meshes Packed Bed Rotating Cylinder Electrode

  • Al-Saady, Fouad A.A.;Abbar, Ali H.
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.58-66
    • /
    • 2021
  • Spiral-wound woven wire meshes packed bed rotating cylinder electrode was used for the simultaneous removal of cadmium (Cd) and copper (Cu) from a binary solution. The effects of weight percent of each metal on the removal and current efficiencies were studied at an operating current of 345A, while the effect of current on the removal efficiency of both metals was investigated at three levels of current (240, 345.and 400 mA). The experiments were carried out at constant rotation speed 800 rpm, pH = 3, and a total concentration of metals (500 ppm). The results showed that the removal efficiency of copper increased from 89% to 99.4% as its weight percent increased from 20% to100%. In a similar fashion, the removal efficiency of cadmium increased from 81% to 97% as its weight percent increased from 20% to100%. The results confirmed that the removal efficiency of any metals declined in the presence of the other. Increasing of current resulted in increasing the removal efficiency of both metals at different weight percents. The results confirmed that current efficiencies for removing of copper and cadmium simultaneously decline with increasing of electrolysis time and weight percent of cadmium or with decreasing the weight percent of copper. Current efficiency was higher at the initial stage of electrolysis for all weight percents of metals. The results showed that the decay of copper concentration was exponential at all weight percents of copper, confirming that the electrodeposition of copper is under mass transfer control in the presence of cadmium. While the decay of cadmium concentration was linear at lower weight percent of cadmium then changed to an exponential behavior at high weight percent of cadmium in the presence of copper.

Biosorption of Copper Ions by Recycling of Castanea crenata (밤나무 재활용에 의한 구리 이온의 생물흡착)

  • Choi, Suk Soon
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.307-311
    • /
    • 2014
  • In this present study, Castanea crenata was found as an excellent biosorbent for the removal capability of copper ions among four different wood wastes (Castanea crenata, Pinus densiflora, Larix kaemoferi and Robinia pseudoacaia). Also, the removal efficiencies of 5, 10, 20, 40 and 50 mg/L copper ions using Castanea crenata from aqueous solution were investigated. The most effective particle size of Castanea crenata for removing 5 mg/L copper ions was found to be $43{\sim}63{\mu}m$. When the concentration of Castanea crenata increased, the removal efficiencies of copper ions were enhanced. In addition, when the 0.8 g/100 mL of Castanea crenata was used for 30 min, the removal efficiencies of 20 and 40 mg/L copper ions were 99% and 85%, respectively. Moreover, the chemical treatment of Castanea crenata with 1 M sodium acetate was required to improve the removal ability for 50 mg/L copper ions. Meanwhile, 1 M hydrochloric acid was selected as the optimal desorption agent with 93% desorption efficiency of copper ions for recycling of modified Castanea crenata. Therefore, these experimental results could be employed as economical and practical engineering data for the development of copper removal processes.

Performance Assessment of Electrolysis Using Copper and Catalyzed Electrodes for Enhanced Nutrient Removal from Wastewater

  • Kim, Woo-Yeol;Son, Dong-Jin;Yun, Chan-Young;Kim, Dae-Gun;Chang, Duk;Sunwoo, Young;Hong, Ki-Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.124-132
    • /
    • 2017
  • The performance of electrolytic processes using copper and catalyzed electrodes for enhanced nutrient removal with various catalyzers and combinations of electrodes was evaluated. The catalyzed electrodes removed more ammonia nitrogen than the copper electrode, but higher ammonia removal was achieved using a Pt/Ti anode. On the other hand, electrolysis using the Pt/Cu anode consumed less energy and cost less. During electroreduction, nitrate was better removed by a pair of copper electrodes than by the catalyzed electrodes. During electrolysis of synthetic wastewater, ammonia removal not only increased owing to direct oxidation at the anode, but was also influenced by indirect oxidation at the cathode. Platinum-coated copper and titanium cathodes actively produced oxidizers and thus removed more ammonia than a pure metal cathode. Although phosphorus was removable irrespective of the type of catalyzer, electrocoagulation using the copper electrode achieved complete removal of phosphorus in a period of less than 10 min.

Equilibrium and kinetic studies on the adsorption of copper onto carica papaya leaf powder

  • Varma V., Geetha;Misra, Anil Kumar
    • Membrane and Water Treatment
    • /
    • v.7 no.5
    • /
    • pp.403-416
    • /
    • 2016
  • The possibility of using carica papaya leaf powder for removal of copper from wastewater as a low cost adsorbent was explored. Different parameters that affect the adsorption process like initial concentration of metal ion, time of contact, adsorbent quantity and pH were evaluated and the outcome of the study was tested using adsorption isotherm models. A maximum of 90%-94.1% copper removal was possible from wastewater having low concentration of the metal using papaya leaf powder under optimum conditions by conducting experimental studies. The biosorption of copper ion was influenced by pH and outcome of experimental results indicate the optimum pH as 7.0 for maximum copper removal. Copper distribution between the solid and liquid phases in batch studies was described by isotherms like Langmuir adsorption and Freundlich models. The adsorption process was better represented by the Freundlich isotherm model. The maximum adsorption capacity of copper was measured to be 24.51 mg/g through the Langmuir model. Pseudo-second order rate equation was better suited for the adsorption process. A dynamic mode study was also conducted to analyse the ability of papaya leaf powder to remove copper (II) ions from aqueous solution and the breakthrough curve was described by an S profile. Present study revealed that papaya leaf powder can be used for the removal of copper from the wastewater and low cost water treatment techniques can be developed using this adsorbent.

Removal Characteristics of Copper from Anthraquinone Dyes by Iron Cementation (안트라퀴논계 염료에서 철 교착반응에 의한 구리의 제거 특성)

  • 천재기;이석희;주창식
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.20 no.1
    • /
    • pp.45-53
    • /
    • 2002
  • The removal of chelated copper from anthraquinone dyes by cementation on powdered iron was studied. The removal of chelated copper was found to be a function of solution pH, amount of NTA and iron, and reaction temperature. In the presence of NTA, reaction rate of cementation was found to be strongly dependent on reaction temperature, solution pH, amount of NTA and amount of iron powder. These experimental results can be explained successfully by the distribution of complexed copper iron in solutions.

  • PDF