• 제목/요약/키워드: Cooling Duct

검색결과 119건 처리시간 0.023초

회전하는 터빈 블레이드 내부 이차냉각유로에서 엇갈린요철과 평행요철이 열/물질전달에 미치는 영향 (Effect of Cross/Parallel Rib Configurations on Heat/Mass Transfer in Rotating Two-Pass Turbine Blade Internal Passage)

  • 이세영;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1249-1259
    • /
    • 2002
  • The present study investigates the convective heat/mass transfer inside a cooling passage of rotating gas-turbine blades. The rotating duct has various configurations made of ribs with 70。 attack angle, which are attached on leading and trailing surfaces. A naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. The present experiments employ two-surface heating conditions in the rotating duct because the surfaces, exposed to hot gas stream, are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. In the stationary conditions, the parallel rib arrangement presents higher heat/mass transfer characteristics in the first pass, however, these characteristics disappear in the second pass due to the turning effects. In the rotating conditions, the cross rib present less heat/mass transfer discrepancy between the leading and the trailing surfaces in the first pass. In the second pass, the heat/mass transfer characteristics are much more complex due to the combined effects of the angled ribs, the sharp fuming and the rotation.

차량 엔진룸내 부품 냉각용 덕트 개발을 위한 실험 (Experiment for Duct Development to Cool Components in Vehicle Engine Room)

  • 이석영
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.98-102
    • /
    • 2018
  • 자동차 엔진룸내 부품의 내구성 향상을 위하여 냉각 가능성을 판단하고자 발전기, 배터리, ECU 및 파워스틸 오일 등 4가지 부품을 목표로 흡입공기를 사용한 냉각용 덕트를 설치하여 부품에 대한 공랭효과를 향상시키기 위한 실험을 수행하였다. 실험 결과, 전반적으로 부품 온도가 저감되었으며 감소된 온도 차이는 발전기, ECU, 파워스틸 오일 및 배터리 순으로 크게 나타났다. 이러한 부품에 따른 온도 차이를 개선하기 위해서는 차후에 덕트 내부에 대한 유동해석을 통한 최적화 설계가 필요하다고 판단된다.

일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방 (Greenhouse Cooling Using Air Duct and Integrated Fan and Pad System)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제20권3호
    • /
    • pp.176-181
    • /
    • 2011
  • 온실의 한쪽 벽에 패드를 설치하고 반대쪽 벽에 팬을 설치하여 가동하는 팬 앤 패드 냉방 온실의 온도 경사 문제를 극복하기 위한 목적으로 일체형 팬 앤패드 시스템과 에어 덕트를 설치한 온실의 냉방 실험을 통하여 냉방성능을 분석하였다. 일체형 팬 앤 패드 증발냉각기의 효율은 1단 가동시 75.7%, 2단 가동시 88.6%로 나타나 대체로 우수한 냉각효율을 보이는 것으로 판단된다. 온실의 냉방성능 실험 결과 무차광 조건에서 온실 냉방 시스템을 가동할 경우 대조구 온실에 비해서 $5.7\sim7.6^{\circ}C$ 정도의 냉방효과가 있으며 차광 조건에서는 $7.4\sim9.7^{\circ}C$ 정도의 냉방효과가 있는 것으로 나타났다. 본 시스템을 적용할 경우 여름철 온실의 최고기온을 $37^{\circ}C$ 정도로써 외기온 대비 $5^{\circ}C$ 이내로 유지할 수 있으며, 적절한 차광을 실시할 경우에는 $33^{\circ}C$ 정도에 $2^{\circ}C$ 이내로 유지하는 것이 가능하여 고온기 작물재배에 큰 도움을 줄 수 있을 것으로 생각한다. 한편, 본 냉방 실험에서 온실의 온도 분포를 분석한 결과 18m 길이의 온실 내 최대 온도 편차는 차광시 $1.6\sim1.7^{\circ}C$, 무차광시 $2.3\sim2.7^{\circ}C$ 정도로 나타났다. Kittas 등(2003)과 Nam 등(2005)의 자료와 비교한 결과 본 연구에서 구상한 일체형 팬 앤 패드 시스템과 에어 덕트를 이용한 온실 냉방시스템은 기존의 팬 앤 패드 냉방 온실의 최대 단점인 온도 편차를 40~50% 정도 개선할 수 있는 것으로 나타났다. 본 시스템은 자연환기 상태에서 가동할 수 있으므로 단동 온실에 적용하기가 쉬우며, 일체형 증발냉각기 출구로부터 온실 내 에어 덕트 시점까지의 연결 덕트 부분을 철저하게 단열하면 냉방성능을 더욱 향상시킬 수 있을 것으로 판단된다.

자동차 냉/난방 성능 향상을 위한 공기조화 덕트의 기류해석 (Aerodynamic Analysis of Automotive HVAC Duct for Enhancement of Cooling/Heating Performance)

  • 주재우;이기돈;허만웅;김광용;박준규;윤정환;김홍빈
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.23-28
    • /
    • 2012
  • In the present work, numerical analyses of air flow in HVAC duct have been carried out for enhancement of cooling/heating performance. For the analyses, three-dimensional Reynolds-averaged Navier-Stokes equations have been solved with the shear stress transport turbulence model. The numerical results were validated in comparison with the experimental data. Based on the numerical results, the HVAC duct was designed to reduce the pressure loss. The modified duct geometry shows largely reduced pressure drop in comparison with the reference geometry. And, through modified duct shape, the performance of air conditioning has been enhanced.

쐐기형 요철이 설치된 사각덕트에서의 열/물질전달 및 압력강하 특성 (Heat/Mass Transfer and Pressure Drop in A Square Duct with V-Shaped Ribs)

  • 최청;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1542-1551
    • /
    • 2002
  • The present study investigates the convective heat/mass transfer characteristics and pressure drop inside the rib-roughened cooling passage of gas turbine blades. The internal cooling passage is simulated using a square duct with h- and V-shaped rectangular ribs which have a 60。attack angle. A naphthalene sublimation technique is employed to determine the detailed local heat/mass transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wail. The secondary flow patterns and the local heat transfer in the duct are changed significantly according to the rib orientation. A square duct with ∧ - and V-shaped ribs have two pairs of secondary flow due to the rib arrangement. Therefore, the average heat/mass transfer coefficients and pressure drop of ∧ - and V-shaped ribs are higher than those of the continuous ribs with 90$^{\circ}$ and 60$^{\circ}$attack angles. The ∧-shaped ribs have higher heat/mass transfer coefficients than the V-shaped ribs, and the uniformity of heat/mass transfer coefficient are increased with the discrete ribs due to the flow leakage and acceleration near the surface.

정사각덕트의 코너부에서 이차유동 특성 (A Characteristics of a Secondary flow in a Corner Section of Square Duct)

  • 정정무;김지환;유영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.753-758
    • /
    • 2000
  • Heat engine and fluid machinery in the plant have to linked with various ducts network and the corresponding design have to be concerned about effectiveness and stability of system of plant. To optimum control and design system concerning stability, economization, operating effectiveness we have to exact analysis flow properties of a duct applying to fluid machinery, heat exchanger, cooling machine, air conditioning equipment. therefore, it is necessary to research the duct, heat transfer equipment, for increasing overall effectiveness of air conditioning system by suggesting basic data of the duct resulting from organic research. So we can contribute to technical development of the duct. In case of speeding up the flow rate of the duct, lots of wave velocity components are occurred the value of boundary layer resulting from developing the boundary layer at both walls of duct.

  • PDF

경기지역 젖소 농가 고온저감시설 활용 실태조사 및 축사내 온습도 변화 (The Survey and its Effect for Cooling Systems used in Dairy Cattle Farms in Gyeonggi)

  • 이준엽;최희철;이동현;우샘이;기광석;전중환
    • 한국축산시설환경학회지
    • /
    • 제21권2호
    • /
    • pp.55-64
    • /
    • 2015
  • This survey was conducted to give the basic information and temperature and humidity variation by cooling systems in dairy farms in Korea. A total of 36 farms were surveyed in Gyeonggi province with the general information of farms such as milk production, and milk quality, types of cooling systems, and its operation method of dairy farms. All of surveyed farms have cooling fan and some have 1 more cooling systems such as sprinkler, foggy systems, ventilation duct, and shower system. Although the indoor THI of cow house was decreased by either ventilation duct or foggy system during hot season, the range belongs to mild heat stress scale for dairy cows.

일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용;박영두
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

플라스틱 연료탱크 생산 설비에서의 소비 전력 저감을 위한 공조 시스템 설계 및 경제성 평가 (Design and Economics of HVAC System for Reduction of Power Consumption in Blow Mold Machine)

  • 이영재;최석천
    • 동력기계공학회지
    • /
    • 제21권4호
    • /
    • pp.84-93
    • /
    • 2017
  • This study was carried out to improve the electric power consumption of HVAC in the blow mold machine(BMM) and work environment. The experiment was conducted with the simulated HVAC system of 1/15 of the actual BMM. The temperature of main facility and two preheaters was fixed at 200 and $60^{\circ}C$ respectively in all test conditions. The measured points of temperature were chosen as critical locations considering the work environment. The tendency of temperature distributions decreases as the duct was closed to the main facility. The reduction rate of power consumption of HVAC increases up to 32.3% when both duct and cooling systems are operated. Also the efficiency of HVAC is improved about 9% through the modified design of duct system. It notes that the electric power consumption of HVAC can be reduced by the optimum design and operating condition of duct and cooling system.

일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF