• 제목/요약/키워드: Cooling Center

Search Result 960, Processing Time 0.034 seconds

Design of Fan Balancing System for Detecting Unbalance of Automobile Cooling Fan (자동차용 냉각팬의 불량검출을 위한 팬 밸런서 시스템 개발)

  • Youk, Yui-Su;Kim, Sung-Ho
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.273-275
    • /
    • 2008
  • Generally, automobile cooling fan is used to lower the temperature of radiator. The cooling fans are manufactured by plastic injection molding process. The center of gravity of cooling fan is often deviated from the center because of the use of deteriorated materials. As the unbalance of the cooing fan can generate noise, it is required to test the performance of the cooling fans. In this work, automatic fan balancer which can distinguish between the good and the bad, futhermore idenfify the position and magnitude of unbalance is develpoed.

  • PDF

Engine Room Layout Design Optimization of Fuel Cell Vehicle Using CFD Technique (CFD를 이용한 연료전지 차량 레이아웃 최적화)

  • Kim, Jung-Ill;Jeon, Wan-Ho;Cho, Jang-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.4
    • /
    • pp.99-106
    • /
    • 2011
  • This paper deals with engine room layout design optimization of fuel cell electric vehicle (FCEV), which has been proposed as a potential alternative to fossil fuel depletion. Investing the great R&D efforts, the global vehicle manufacturers, especially Honda motor corporate, have shown not prototype vehicle but commercial vehicle using fuel cell in the market recently. In this paper, we analyze cooling performance and flow characteristic in the engine room of newly FCEV, in addition we suggest the optimization process for engine room layout design optimization. The two radiators in the vehicle for fuel cell stack and electronic components cooling have been analyzed and their performance are obtained in terms of cooling performance ratio (CPR). The value of CPR should always be less than one and based on criteria, we have achieved the optimum cooling performance of radiators for stack and electronic components. Aerodynamic performance is evaluated in terms of drag coefficient, improved through underbody modification using air devices.

Power and Heat Load of IT Equipment Projections for New Data Center's HVAC System Design (데이터센터의 공조시스템 계획을 위한 IT장비의 전력 및 발열량 예측에 대한 연구)

  • Cho, Jin-Kyun;Shin, Seung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.212-217
    • /
    • 2012
  • The cooling of data centers has emerged as a significant challenge as the density of IT equipment increased. With the rapid increasing of heat load and cooling system, predictions for electronics power trends have been closely watched. A data center power density projection is needed so that IT organizations can develop data centers with adequate cooling for reasonable lifetimes. This paper will discuss the need for something more than processor and equipment power trend projections which have overestimated the required infrastructure for customers. This projection will use data from a survey of actual enterprise data centers and the ASHRAE projections to formulate a data center server heat load trend projection.

Characteristic of Refrigerant for Heat-treatment Deformation Control of SM45C Steel (SM45G강의 열처리변형 제어를 위한 냉각매질의 특성)

  • Lyu, S.;Nam, T.;Ahn, M.;Park, J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.330-336
    • /
    • 2000
  • This study deals with the characteristic of refrigerant for heat-treatment deformation control of SM45C steel. The control of heat-treatment deformation must need the progress of production parts for a landing gear. Most of the deformation is occurred on unequal cooling. The unequal cooling is occurred by a property of quenching refrigeration. When a heated metal is deposited in the refrigeration, the cooling speed is so slow in early period of cooling because of occurring a steam-curtain. After more cooling, the steam-curtain is destroyed. In this progress, the cooling speed is very fast. The object of this study is to control the deformation of heat-treatment for landing gear by improving the conditions of quenching. The cooling curves and cooling rates of water, oil and polymer solution are obtained and illustrated. From the characteristics of the quenching refrigerant, the effects of heat-treatments on thermal deformation and fatigue strength are also investigated.

  • PDF

A District Cooling System using Ice Slurry for the Uncertain Cooling Load of the Future and its Economic Evaluation (미래의 불확실한 냉방부하에 대한 아이스슬러리를 이용한 지역냉방시스템 및 경제성 평가)

  • Lee Yoon-Pyo;Ahn Young-Hwan;Yoon Seok-Mann
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.776-782
    • /
    • 2006
  • A new district cooling system using ice slurry for the uncertain cooling load of the future is presented. The chilled water produced by the absorption chillers is used for the base cooling load. The temperature of the chilled water is reduced by mixing of ice slurry depending on increasing of the cooling load. Finally, IF of the ice slurry is increased up to 10% at the peak load. The transporting mass flow rate is decreased down to 44.7%, and the diameter of the main pipe is decreased down to 66.7%, but the diameter of the branched pipe is designed as the same size of the chilled water.

Performance Characteristics of the Thermal Management System for Passenger Hydrogen Fuel Cell Vehicle (수소연료전지 자동차의 열관리시스템 성능특성에 관한 연구)

  • Lee, Ho-Seong;Won, Jong-Phil;Cho, Chung-Won;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.986-993
    • /
    • 2012
  • The objective of this study is to investigate performance characteristics of the thermal management system for passenger hydrogen fuel cell vehicle under various operating conditions. The thermal management systems comprised of a stack cooling system, an electric device cooling system and an air conditioning system for a passenger room were tested with driving conditions. As a result, in highway driving mode, the cooling performance of the stack cooling system with air conditioning on condition was 28.8 % lower than that of the air conditioning off condition. And cooling load of the electric cooling system in the city driving mode was 65.6% higher than that of the highway driving mode.

Stabilization of Water Balance of Closed Cooling Water System with Orifice (오리피스를 통한 기기냉각수 계통 Water Balance 정상화)

  • Lee, Sung Gun;Park, Jong Hwan;Lee, Eun Su
    • Plant Journal
    • /
    • v.13 no.4
    • /
    • pp.38-40
    • /
    • 2017
  • This study is for stabilization of the water balance of the closed cooling water system. The pipe network analysis program is used for the water balance review, and the resistance factor correction is performed through the field measurement with the ultrasonic flowmeter to improve the reliability of the pipe network software. Based on this, it is aimed to derive optimal driving method through various case simulations.

  • PDF

Comparison of Clinical Outcomes Using Various First-Aid Cooling Method for Burn (다양한 화상 응급처치의 치료효과 비교)

  • Lee, Jung Hwan;Song, Woo Jin;Kwon, Min Ju;Park, Yang Seo;Ko, Jang Hyu
    • Journal of the Korean Burn Society
    • /
    • v.24 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • Purpose: Currently, the most recommended method for burn first aid is the cool running water for 20 minutes (CRW20). If CRW20 is not practicable, cooling dressing products with tea tree oil are used as substitutes. In this study, we analyze the effect of various burn first aids, including CRW20, cooling products, on the treatment period. Methods: This study was conducted on patients who suffered burns and visited Hangangsoo Hospital from March 2019 to March 2020. The study conducted in a retrospective method. The duration of treatment was analyzed by dividing the experimental group. Results: The treatment period was shortened when first aid was given (P<0.001). Cold water, ice, and ice packs resulted in reduced treatment periods (P<0.001, P=0.004). The treatment period was reduced when cooling dressing products were used in all groups (P=0.041). The implementation of first aid has reduced the duration of burn treatment. This means that cooling helps burn treatment. CRW20 did not show statistically meaningful results. This is the result of a failure to fully control the temperature and time of tap water. In addition, the change in temperature of tap water according to season, the use of water is higher than that of animal testing, and the general lack of information on proper burn first aid may have affected. Conclusion: The treatment period was statistically significantly reduced in the group that performed first aid. Among the various first aid methods, cold water and ice reduced the treatment period.

Cryopreservation of Scutellaria baicalensis Cells by Two-step Cooling Method

  • Seo, Weon-Taek;Kim, Suk-Weon;Liu, Jang-Ryol;Kim, Ik-Hwan;Park, Young-Hoon;Choe, Tae-Boo
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.3
    • /
    • pp.209-212
    • /
    • 1996
  • A two-step cooling technique has been developed for cryopreservation of suspension cultured Scutellaria baicalensis cells. Efficient regrowth of cryopreserved cells was obtained in cryoprotected cells with a mixture of 1.5 M glycerol and 0.4 M sucrose in Schenk and Hildebrandt medium without pretreatment in high osmotic medium. Optimum freezing conditions were found to be a cooling rate of $0.5^{\circ}C$ min from $4^{\circ}C$ to $-40^{\circ}C$, and then retaining samples at $-40^{\circ}C$ for 30 min prior to plunging into liquid nitrogen. A regrowth rate of approximately 95$%$ was obtained after three month storage in liquid nitrogen. Callus cultures established from the cryopreserved cells were found to produce the same patterns of flavonoid accumulation and retain their baicalin producing activity.

  • PDF

The Microstructural Evolution of Mg-10Al-Mn Alloy by Cooling Plate During Homogenization Treatment (냉각판법에 의한 Mg-10Al-Mn 합금의 균질화 처리에 따른 미세조직 변화)

  • Kim, Dae-Hwan;Choi, Seung-Hwa;Kim, Hee-Kyung;Shim, Sung-Young;Lim, Su-Gun
    • Journal of Korea Foundry Society
    • /
    • v.30 no.6
    • /
    • pp.235-240
    • /
    • 2010
  • The evolution of microstructure and phases of Mg-10Al-Mn alloy by cooling plate method during homogenization treatment have been investigated with metallographic analysis, scanning electron microscopy and energy dispersive spectroscopy. The ingots used for this experiment were prepared by cooling plate and homogenization heat treatment was performed at 300 and $400^{\circ}C$ for various holding times (0, 1, 4, 8 and 12h). The casting ingots were consisted of the fine grains and eutectic phases. And, these eutectic phases were dissolved into the matrix during homogenization treatment at $400^{\circ}C$ but the lower temperature (at $300^{\circ}C$) did not be.