• Title/Summary/Keyword: Convertor

Search Result 179, Processing Time 0.029 seconds

ZVZCS(Zero-Voltage and Zero-Current-Switching Three-Level DC/DC Converter reducing voltage stress of auxiliary circuit (보조 회로의 전압 스트레스를 저감한 ZVZCS Three-Level DC/DC 컨버터에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Baek, Soo-Hyun;Cho, Kyu-Man;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.172-174
    • /
    • 2005
  • A ZVZCS(Zero-Voltage and Zero-Current-Switching) Three-Level DC/DC Convertor reducing voltage stress of auxiliary circuit is proposed. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 2kW 40kHz IGBT based experimental circuit.

  • PDF

Development of Plastic Film Type Submersion Sensor (플라스틱 필름형 침수센서 개발)

  • Lee, Young Tae;Kwon, Ik Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.107-111
    • /
    • 2022
  • In this paper, a plastic film type submersion sensor capable of measuring submersion speed was developed. This submersion sensor is designed as a capacitive type, and it is a sensor that outputs the change in capacitance between the electrode of the submersion sensor and the grounded body as a voltage through a C-V(capacitance-voltage) converter. We developed an submersion sensor in which two electrodes of different lengths are connected in parallel to measure the submersion speed accurately by minimizing the influence of noise such as contamination. When both electrodes of the submersion sensor are exposed to water, the rate of change of water level suddenly increases, so the submersion speed is measured by measuring the time to this point. Since the difference in length between the two electrodes of the submersion sensor does not change in any case, it is possible to accurately measure the submersion speed.

STATCOM Helps to Guarantee a Stable System

  • Andersen, B.R;Gemmell, B.D.;Horwill, C.;Hanson, D.J.
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.65-70
    • /
    • 2001
  • Transmission System Operators are governed by operational security standards that are applied in real time. During system disturbances, the System Operators must rely on the installed protection and control equipment, prior to human intervention. New power electronic solutions bring rapid and repeatable responses to disturbances, which will help System Operators to guarantee a stable system. Last year, Alstom completed the world's first competitively bid STATCOM to support the voltage on National Grid's 400kV network that supplies London and the Southeast from the north of the UK. It is rated ${\pm}75MVAr$ and forms part of a Static Var System (SVS) with a total rating of 0 to 225MVAr. This paper will describe the reasons for its size, location, its chain-link configuration and give examples of its operating performance. The paper will also describe the features that allow this STATCOM to deliver much more than reactive compensation in support of a wider transmission service objective, as system conditions require.

  • PDF

Speech Generation Using Kinect Devices Using NLP

  • D. Suganthi
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.2
    • /
    • pp.25-30
    • /
    • 2024
  • Various new technologies and aiding instruments are always being introduced for the betterment of the challenged. This project focuses on aiding the mute in expressing their views and ideas in a much efficient and effective manner thereby creating their own place in this world. The proposed system focuses on using various gestures traced into texts which could in turn be transformed into speech. The gesture identification and mapping is performed by the Kinect device, which is found to cost effective and reliable. A suitable text to speech convertor is used to translate the texts generated from Kinect into a speech. The proposed system though cannot be applied to man-to-man conversation owing to the hardware complexities, but could find itself very much of use under addressing environments such as auditoriums, classrooms, etc

Design and Implementation of the JAVA Serial Communication Program to Control the Industrial Digital Indicator (산업용 디지털 지시계 제어를 위한 자바 시리얼 통신 프로그램의 설계와 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo;Lee, Jung-Hwa
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.6
    • /
    • pp.794-801
    • /
    • 2011
  • Main machinery in the factory have various digital indicator to display its operating data for the manager. It is useful to control these datum at the remote office for factory automation in order to increase machine productivity. It is easy to use Ethernet infrastructure for remote communication. But most of all machinery in domestic factories still support RS232c or RS485 serial communication way. In this case to control machinery datum on the ethernet base, it is need to change RS232C or RS485 data to ethernet base. In this paper, in order to develop a remote progress management system through the wireless Internet, we show a design method to make easy maintenance by developing the system with both the JAVA language and RxTx Package for RS232c serial communication. For the system implementation, we added the digital indicator connect with a thermo couple to a machine which provide the real time status data of temperature. To connect machines management server program, we set up a convertor to change the RS485 data to the RS232c and also another convertor to change the RS232c data to wireless ethernet.

A Study on the Inverter performance by Simulated Converter (시뮬레이터 컨버터에 의한 인버터 성능시험에 관한 연구)

  • Jho, J.M.;Jho, J.H.;Kim, S.N.;Lee, S.H.;Oh, S.H.;Lee, H.G.;Kim, Y.J.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.983-985
    • /
    • 2002
  • This paper is the machine that is able to estimate a new built power convertor in a production line. Generally, this machine test can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. But the proposal system is controlled to create some specific load characteristic needed for the test without any mechanical equipment. The suggested test stand consists only of a converter to be test and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. And then, to obtain a superior characteristic for dynamic reference used the feedforward control.

  • PDF

The study of proton exchange membrane fuel cell and Li-poly battery hybrid system (로봇용 연료전지 이차전지 하이브리드 시스템 연구)

  • Kwon, O-Sung;Lee, Sang-Cheol;Lee, Sang-Woo;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.282-288
    • /
    • 2012
  • Proton exchange membrane fuel cell (PEMFC) is the most promising energy source for the robot applications because it has unique advantages such as high energy density, no power drop during operating, and easy to make compact size. However, PEMFC has intrinsic disadvantages which are delay to start up and difficulty to correspond drastic load changes. These disadvantages can be compensated by hybrid operating with a Li-poly battery. This study is focus to build and understand the hybrid system for the robot system. In this study, we build the PEMFC hybrid system using EOS-320 PEMFC stack, Li-poly battery and G-Philos FDX1-250BU dc-dc converter. The hybrid system is accurately monitored by CAN and RS485. The system was studied under two conditions such as non-loaded and loaded operating conditions. The results show that the system has delay to start up without hybrid operating and it can be compensated with the hybrid operating.

New Battery Balancing Circuit using Magnetic Flux Sharing

  • Song, Sung-Geun;Park, Seong-Mi;Park, Sung-Jun
    • Journal of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.194-201
    • /
    • 2014
  • To increase the capacity of secondary cells, an appropriate serial composition of the battery modules is essential. The unbalance that may occur due to the series connection in such a serial composition is the main cause for declines in the efficiency and performance of batteries. Various studies have been conducted on the use of a passive or active topology to eliminate the unbalance from the series circuit of battery modules. Most topologies consist of a complex structure in which the Battery Management System (BMS) detects the voltage of each module and establishes the voltage balancing in the independent electrical power converters installed on each module by comparing the module voltage. This study proposes a new magnetic flux sharing type DC/DC converter topology in order to remove voltage unbalances from batteries. The proposed topology is characterized by a design in which all of the DC/DC convertor outputs connected to the modules converge into a single transformer. In this structure, by taking a form in which all of the battery balancing type converters share magnetic flux through a single harmonic wave transformer, all of the converter voltages automatically converge to the same voltage. This paper attempts to analyze the dynamic properties of the proposed circuit by using a Programmable Synthesizer Interface Module (PSIM), which is useful for power electronics analysis, while also attempting to demonstrate the validity of the proposed circuit through experimental results.

Experimental study on multi-level overtopping wave energy convertor under regular wave conditions

  • Liu, Zhen;Han, Zhi;Shi, Hongda;Yang, Wanchang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.5
    • /
    • pp.651-659
    • /
    • 2018
  • A multi-level overtopping wave energy converter was designed according to the large tidal range and small wave heights in China. It consists of two reservoirs with sloping walls at different levels. The reservoirs share a common outflow duct and a low-head axial turbine. The experimental study was carried out in a laboratory wave-flume to investigate the overtopping performance of the device. The depth-gauges were used to measure the variation of the water level in the reservoirs. The data was processed to derive the time-averaged overtopping discharges. It was found that the lower reservoir can store wave waters at the low water level and break the waves which try to climb up to the upper reservoir. The upper sloping angle and the opening width of the lower reservoir both have significant effects on the overtopping discharges, which can provide more information to the design and optimization of this type of device.

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF