• Title/Summary/Keyword: Converter Transformer

Search Result 791, Processing Time 0.023 seconds

A New Flyback Converter Using the Cross Flux of Transformer (교차 자속을 이용한 새로운 플라이백 컨버터)

  • Ku, Bok-Jae;Kim, Hyo-Seon;Park, Sung-Jun;Park, Seong-Mi
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.73-82
    • /
    • 2014
  • This research proposes a new type of flyback converter topology based on magnetic circuit sharing. The proposed flyback topology uses a transformer involving shared magnetic flux, and its characteristic is magnetic flux cancelation by cross magnetic flux in the magnetic flux-sharing part of the core. The new topology aims to reduce the volume of transformer by reducing the cross section of the core. Compared to conventional converters using only 1 transformer, its circuit configuration involving the serial input and parallel output of 2 flyback coils allowed increased converter insulation strength. In addition, the adoption of interleaved switching method achieved the improvement of output voltage ripple, while magnetic circuit sharing reduced by 50% the cross section of core where magnetic circuit was shared.

Zero-Voltage Switching Two-Transformer Full-Bridge PWM Converter With Lossless Diode-Clamp Rectifier (새로운 무 손실 다이오드 클램프 회로를 채택한 두 개의 트랜스포머를 갖는 영 전압 스위칭 풀 브릿지 컨버터)

  • Yoon H. K.;Han S. K.;Park J. S.;Moon G. W.;Youn M. J.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.551-555
    • /
    • 2004
  • The two-transformer full bridge (TTFB) PWM converter has two transformers which act as the output inductor as well as the main transformer, i.e. as the forward and the flyback transformer. Although the doubled leakage inductor of the TTFB makes it easier to achieve the zero-voltage switching (ZVS) of the lagging leg switch along the wide load range, it instigates a serious voltage ringing in the secondary rectifier diodes, which would require the dissipative snubber circuit, cause the serious power dissipation, and increase the voltage stress across those diodes. To overcome these problems, a, new lossless diode-clamp rectifier (LDCR) is employed as the output rectifier, which helps the voltage across rectifier diodes to be clamped on a half the output voltage $(V_o/2)$ or the output voltage $(V_o)$. Therefore, no dissipative snubber for rectifier diodes is needed and a high efficiency as well as low noise output voltage can be realized. The operations, analysis and design consideration of proposed converter are presented in this paper. To verify the validity of the proposed converter, experimental results from a 425W, 385-170Vdc prototype for the plasma display panel (PDP) sustaining power module (PSPM) are presented.

  • PDF

A Study of the Three Port NPC based DAB Converter for the Bipolar DC Grid (양극성 직류 배전망에 적용 가능한 3포트 NPC 기반의 DAB 컨버터에 대한 연구)

  • Yun, Hyeok-Jin;Kim, Myoungho;Baek, Ju-Won;Kim, Ju-Yong;Kim, Hee-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.336-344
    • /
    • 2017
  • This paper presents the three-port DC-DC converter modeling and controller design procedure, which is part of the solid-state transformer (SST) to interface medium voltage AC grid to bipolar DC distribution network. Due to the high primary side DC link voltage, the proposed converter employs the three-level neutral point clamped (NPC) topology at the primary side and 2-two level half bridge circuits for each DC distribution network. For the proposed converter particular structure, this paper conducts modeling the three winding transformer and the power transfer between each port. A decoupling method is adopted to simplify the power transfer model. The voltage controller design procedure is presented. In addition, the output current sharing controller is employed for current balancing between the parallel-connected secondary output ports. The proposed circuit and controller performance are verified by experimental results using a 30 kW prototype SST system.

High Efficiency Switch Mode Line Transformer (SMLT) Composed of Load Sharing Dual Modules (부하평형 듀얼 모듈로 구성된 고효율 스위치 모드 라인 트랜스포머(SMLT))

  • Kim, Jin-Hong;Yang, Jung-Woo;Jang, Du-Hee;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.188-194
    • /
    • 2020
  • This paper presents a high-efficiency Switch Mode Line Transformer (SMLT) composed of load-shared dual modules, which is based on the AC/AC LLC resonant converter. Given that the conventional adaptor is usually composed of two power stages, namely, the PFC and DC/DC converters, its system size can be increased according to the output power. However, given that the proposed SMLT can separate the PFC converter from the adaptor, the size reduction of the system can be achieved. Meanwhile, the SMLT with a single module has the limit of the size reduction because of a high resonant current. Thus, it can be configured with dual or multiple modules to reduce the resonant current. Then, their load sharing can be guaranteed by only the proposed transformer structure without an extra current controller. The validity of the proposed converter is proven through a 850-W prototype.

Development of Planar Transformer and SiC Based 3 kW High Power Density DC-DC Converter for Electric Vehicles (플라나변압기와 SiC 기반의 전기자동차용 3kW 고전력밀도 DC-DC 컨버터 개발)

  • Kim, Sangjin;Suk, Chaeyoung;Hakim, Ramadhan Muhammad;Choi, Sewan;Ryu, Byoungwoo;Park, Sanghun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.2
    • /
    • pp.112-119
    • /
    • 2021
  • This study proposes a design method of high-power-density and high-efficiency low-voltage DC-DC converters using SiC MOSFET and the optimized planar transformer design procedure based on the figure-of-merit. The secondary rectifying circuit of the phase-shifted full-bridge converter is compared to achieve high power density and high efficiency, and the phase-shifted full bridge converter with a current-doubler rectifier is selected. The planar transformer is designed by the proposed optimized design procedure and verified by FEA simulation. To validate the proposed design method, experimental results from a 3 kW prototype are provided. The prototype achieved 95.28% maximum efficiency and a power density of 2.98 kW/L.

Transformer Leakage Inductance Calculation Used in DAB Converters Considering the Influence of SiC MOSFET Parasitic Capacitance (SiC MOSFET 기생 커패시턴스의 영향을 고려한 DAB 컨버터에 사용되는 변압기의 누설인덕턴스 계산)

  • Cheol-Woong Choi;Jae-Sub Ko;Ji-Yong So;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.935-942
    • /
    • 2024
  • This study analyzes the effects of the parasitic capacitance of the SiC MOSFET used in the Dual Active Bridge ( DAB) converter and proposes a method for calculating the leakage inductance of the transformer. The DAB converter employs high-frequency switching to achieve high efficiency, high power density, and reliability. MOSFETs possess parasitic capacitance, which induces resonance with the leakage inductance of the transformer during switching operations, resulting in a voltage change delay. This paper discusses the effect of the delay of voltage changes on the DAB converter output and proposes a method to calculate the delay time. This method aims to equalize the delay time to minimize this effect and enhance the accuracy of the leakage inductance calculation of the transformer. The proposed method is validated through experiments and simulations.

Analysis and Design of Quadruple-Active-Bridge Converter Employing Passive Power Decoupling Capability (수동 전력 비동조화가 가능한 QAB 컨버터의 분석과 설계에 관한 연구)

  • Yun, Chang-Woo;Lee, Jun-Young;Baek, Ju-Won;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.157-164
    • /
    • 2022
  • This study proposes an enhanced quadruple-Active-Bridge (QAB) converter that can solve power coupling problems. By adopting a multiple winding transformer, the equivalent circuit of a conventional QAB converter has power couplings between arbitrary output ports. This coupling is an unintended power relationship that complicates the regulation of output voltage of the multiple ports. The proposed converter can carry out power decoupling by changing the arrangement of the coupling inductor. Power transfer equations for the proposed converter and its operating principles are analyzed in detail. The power coupling caused by the transformer's leakage inductance is verified by using a proposed coupling factor that presents the relationship between inductance ratio and coupling power. In addition, the decoupling power control performance of the proposed converter is verified by simulation and a 3 kW prototype converter.

A Contact-less Power Supply for Photovoltaic Power Generation System (태양광 발전 시스템을 위한 무접점 전원장치)

  • Lee, Hyun-Kwan;Kong, Young-Su;Kim, Yoon-Ho;Lee, Gi-Sik;Kang, Sung-In;Chung, Bong-Geun;Kim, Eun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.216-223
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer Is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without my auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transformer are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

New Single-Stage High Power Converter Using Transformer Magnetizing Energy (변압기 자화 에너지를 이용한 새로운 단일전력단 고역률 컨버터)

  • 문건우;노정욱;정영석;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.35-38
    • /
    • 1996
  • A new high power factor converter using transformer magnetizing energy for power factor correction with a single-switch/single-stage is proposed. The proposed converter gives the good power factor correction, low current harmonic distortions, and tight output voltage regulation. The prototype shows the IEC555-2 requirements are met satisfactorily with nearly unity power factor.

  • PDF

Modeling and Analysis of Zero Voltage Switching PWM Half Bridge DC/DC Converter (영전압 스위칭 PWM 하프 브릿지 컨버터의 모델링 및 분석)

  • 강정일;정영석;노정욱;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.101-110
    • /
    • 1997
  • The circuit effects due to the transformer primary side series equivalent inductance in the Zero Voltage Switching Pulse Width Modulated Half Bridge DC/DC Converter and its impact on the effective duty are analyzed. The steady state equations and the small signal model of the converter are derived incorporating the effects of the complementary control and the utilization of transformer primary side series equivalent inductance. The open plant dynamics are analyzed on the basis of the model derived. The model predictions are confirmed by experimental measurements.

  • PDF