• Title/Summary/Keyword: Conversion Factor

Search Result 970, Processing Time 0.03 seconds

Experimental Study on the Relationships between Earthwork Volumes and Soil Conversion Factor with Depth (심도별 토량환산계수와 토공량 변화에 관한 실험적 연구)

  • Gichun Kang;Kyoungchul Shin;Seong-kyu Yun
    • Land and Housing Review
    • /
    • v.14 no.3
    • /
    • pp.137-144
    • /
    • 2023
  • The amount of soil cutting, transported, and filing up the soil in the project area is considered to change the volume depending on the condition of the soil; the volume change rate of the soil is calculated by collecting undisturbed samples below 1 m to 2.0 m above the surface through test pits. In this study, large-scale field tests are carried out. There are areas with an excavation depth of 10m or more, but some errors have occurred in calculating the soil volume by uniformly applying the soil conversion factor for a depth of 1 to 2 m. According to the field tests, the earthwork volumes applied with the soil conversion factor for each depth increase by 3.9 to 9.4% compared to the soil volume applied uniformly with that of 2 m depth.

Bridgeless High Efficiency ZVZCS Power Factor Correction Circuit for PDP Power Module (PDP용 브리지가 없는 고효율 ZVZCS 역률개선회로)

  • Cho Kyu-Min;Yu Byung-Gyu;Moon Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.704-708
    • /
    • 2004
  • Recently, many nation have released standard such as IEC 61000-3-2 and IEEE 59, which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC Line. Therefore, Plasma Display Panel (PDP) which is highlightened in digital display device also has the Power Factor Correction (PFC) circuit to meet the harmonic requirements. In PDP power module, the conventional boost converter is usually used for the PFC circuit. However, it comes serious thermal problem on it's bridge diode due to heat of PDP, and therefore the system stability is not guaranteed. In this paper, the bridgeless boost converter, which is used for PFC circuit of the PDP power module, is designed and verified the possibility of the application in a practical product in a view of efficiency, component count, temperature and etc.

  • PDF

Characteristics of axial vibration of marine diesel engine crankshafts (박용디이젤기관의 크랭크축계 종진동특성에 관한 연구)

  • 전효중;왕지석;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.22-28
    • /
    • 1983
  • In former papers which were published already, authors had derived calculation formulae for the axial stiffness and the radial force conversion factor of crankshaft. In this paper, crankthrow axial stiffness and radial force conversion factors of actual engines are calculated by these theoretical formulae and then their characteristics are investigated. As the results, the axial stiffness and the radial force conversion factor of the latest super-long stroke engine are smaller than those of old-type engines. The influence of the former brings down the resonance speed of engine and the latter reduces the exciting force of axial vibration, but as the harmonic component of axial vibration force becomes rather strong, its effect of reducing is considerably canceled. In conclusion, as the latest super-long stroke engine is seemed to be liable to axial vibration of crankshafat, it is recommend that, in the design stage of propulsion shaft, its axial vibration condition must be more carefully checked.

  • PDF

Energy Conversion in the Rossby Adjustment Process for Step-Like Initial Disturbances (初期攪亂에 의한 로스비 形過程에 있어서의 에너지 換)

  • 성영호
    • 한국해양학회지
    • /
    • v.21 no.3
    • /
    • pp.131-135
    • /
    • 1986
  • Conversion of energy from potential to kinetic form is considered when a step-like initial disturbance is released to reach a final steady state. For small amplitute disturbances, linearization can be made and it is proved analytically that the conversion factor (ratio of generated kinetic to loss in potential energies) asymptotically approaches to 1/3 as the horizontal scale of disturbances becomes large.

  • PDF

Direct Conversion Sintering of Super-hard Nano-polycrystalline Diamond from Graphite

  • Sumiya, Hitoshi;Irifune, Tetsuo
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1309-1310
    • /
    • 2006
  • High-purity and super-hard nano-polycrystalline diamond has been successfully synthesized by direct conversion from high-purity graphite under static pressures above 15 GPa and temperatures above $2300^{\circ}C$. This paper describes research findings on the formation mechanism of nano-structure and on the contributing factor leading to high hardness.

  • PDF

A Study on Characteristic for a Maximum Utilization Factor of Transformer with Regard to Load Characteristics in General Customers (일반용전력사용고객 용도별 부하특성을 고려한 변압기최대이용률 비교 특성 연구)

  • Kim, Se-Dong;Wang, Yong-Peel;Hong, Hyun-Mun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.217-223
    • /
    • 2009
  • This paper shows a reasonable contract power conversion factor, that was made by the systematic and statistical way considering actual conditions, such as investigated contract power and peak power for the last 5 years of each customer for 461 general customers as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried by the linear and nonlinear regression analysis. Therefore, this paper compared characteristics for a contract power conversion factor which is applied to estimate contract power with characteristics for a regression model for customers(office, store, hotel, hospital, wedding hall) which maximum utilization factor of transformer is more than 60[%].

Rock/Soil proportion estimation using image processing technique (광학식 측정방법을 활용한 풍화지반 버럭의 암/토사 구성비율 추정방법)

  • Jin, Kyu-Nam;Jin, Kim-Young;Park, Sung-Wook;Cho, Gye-Choon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1425-1432
    • /
    • 2010
  • In large construction site, although soil conversion factor is so significant to preliminary design, operation design and calculating the cost of construction that it is important to take reasonable estimation and application, the standard of soil conversion factor for weathered ground doesn't clearly suggested yet. So in this study, at first we obtain the image using DSLR - high resolution camera and Laser scanner in the Haeng-Bok city constructin site, then analysis the ratio of soil and rock using various image processing method(Sobel method, Laplace method, Highpass filter, Hue and Saturation analysis). Mutual comparation with the result of image processing analysis and manual segmentation of 5case image in the cad. As a result, best image processing method was different for each case. In case of high propotion of rock, Laplace was best and in case of high propotion of soil, Highpass was best, and mixed case Laplace was best.

  • PDF

The Conversion factor for Allocation of Interconnection Charge Between Fixed and Mobile Networks (유무선망 상호접속료 배부를 위한 서비스간 환산계수 연구)

  • Kim, Jae-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3275-3279
    • /
    • 2011
  • The matter of the calculation of the mutual access fee has become one of the hottest issues among service providers and attracted concerns from concerned regulatory authorities. It is essential to conclude a rational and systematic procedure for interconnection costs and charge between fixed and mobile networks. In this paper, I proposed the conversion factor scheme between circuit switched voice and packet switched data service in the domestic CDMA mobile system based on analysis of the rational GSM allocation method of common cost.

THE RELATIVE SUNSPOT NUMBERS FROM 1987 TO 2002 (1987-2002년 태양흑점 관측자료 분석)

  • Kim, K.S.;Cho, K.S.;Park, Y.D.;Moon, Y.J.;Kim, Y.H.;Sim, K.J.
    • Publications of The Korean Astronomical Society
    • /
    • v.18 no.1
    • /
    • pp.25-35
    • /
    • 2003
  • In this paper, we have re-examined the relative sunspot numbers from June 1987 to December 2002 observed at Korea Astronomy Observatory. For this we determined conversion factors (K) for each year data to derive the relative sunspot numbers. The estimated conversion factor ranges from 0.57 to 1.09 and has a trend to decrease with time, which seem to depend on the several effects such as observational system, observation methods, and experience of an observer. Our analysis shows that the newly-determined relative sunspot numbers are in much better agreements with the international sunspot numbers than the previously-determined ones in which the conversion factors were determined only four times. This result implies that we should determine the conversion factor for each year data. From these investigations, we also identified one and half solar cycles form our relative sunspot number.

Method of Estimating Environment Conversion Factor Analyzing Environment Factors of MIL-HDBK-217F (MIL-HDBK-217F의 환경인자 분석을 통한 환경변환계수 추정)

  • Jeong, Da-Un;Yun, Hui-Sung;Lee, Eun-Hak;Kwon, Dong-Soo;Lee, Seung-Hun
    • Journal of Applied Reliability
    • /
    • v.11 no.2
    • /
    • pp.141-149
    • /
    • 2011
  • Environment Conversion Factors, which are stipulated in System Reliability Toolkit, have a lot of advantages once applied in a reliability data handbook such as NPRD-95, during the process of reliability prediction. However, the factors have a restriction in their applications because they don't deal with a few environments, e.g., Missile Launch (ML). In this study, environment factors of various components from MIL-HDBK-217F were analyzed to address this problem. Statistical computations showed that converting from Airborne Rotary Wing (ARW) to Missile Launch (ML) was the most coherent by comparing coefficient of determination. In addition, conversion factors from System Reliability Toolkit and those from the statistical calculations were evaluated in terms of their similarities.