• 제목/요약/키워드: Conventional system

검색결과 14,428건 처리시간 0.04초

보행(步行) 이앙기(移秧機)를 위(爲)한 무선자동제어(無線自動制御) 시스템의 개발(開發)(II) -공시기(供試機)의 포장실험(圃場實驗)- (Development of a Wireless Control System for Rice Transplanter of Walking Type(II) -Field Test of the Experimental Machine-)

  • 김창수;최규홍;민영봉;김성태
    • Journal of Biosystems Engineering
    • /
    • 제17권3호
    • /
    • pp.213-222
    • /
    • 1992
  • To develop the wireless remote opreating system of walking rice transplanter, this study was carried out for manufacturing the wireless remote control system acting upon the transplanter. The first report of this study contained about the construction and operating method of a developed remote control system for 2-row walking type transplanter. It is the second report about the field test for an experimental transplanter being attached a wireless control system and for a conventional transplanter. The test was executed to investigate the characteristics of velocity, rectilinearity, turning time, interval of roots and of rows, and field capacity in accordance with various engine speeds for an experimental transplanter. The measurements of this test were compared with those of the conventional transplanter. The obtained results were as follows : 1. The operating velocity of the experimental transplanter was faster than the conventional one when the high speed range of the engine but the variances were very large. 2. The rectilinearity, interval of raws and of roots, and the turning time of the experimental transplanter was inferior to the conventional one at some speed ranges of the engine. 3. Field capacity of the experimental transplanter was superior to the conventional one at high speed of the engine. 4. There were some disadvantages for the experimental transplanter to operate, because it was constructed without any aid devices, such as float and hydraulic system for instance. But if the remote control system of this study equip at the modern walking transplanter, it will be improved and utilized without defects which was revealed from this test.

  • PDF

Design and Development of a Novel High Resolution Absolute Rotary Encoder System Based on Affine n-digit N-ary Gray Code

  • Paul, Sarbajit;Chang, Junghwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.943-952
    • /
    • 2018
  • This paper presents a new type of absolute rotary encoder system based on the affine n-digit N-ary gray code. A brief comparison of the existing encoder systems is carried out in terms of resolution, encoding and decoding principles and number of sensor heads needed. Using the proposed method, two different types of encoder disks are designed, namely, color-coded disk and grayscale coded disk. The designed coded disk pattern is used to manufacture 3 digit 3 ary and 2 digit 5 ary grayscale coded disks respectively. The manufactured disk is used with the light emitter and photodetector assembly to design the entire encode system. Experimental analysis is done on the designed prototype with LabVIEW platform for data acquisition. A comparison of the designed system is done with the traditional binary gray code encoder system in terms of resolution, disk diameter, number of tracks and data acquisition system. The resolution of the manufactured system is 3 times higher than the conventional system. Also, for a 5 digit 5 ary coded encoder system, a resolution approximately 100 times better than the conventional binary system can be achieved. In general, the proposed encoder system gives $(N/2)^n$ times better resolution compared with the traditional gray coded disk. The miniaturization in diameter of the coded disk can be achieved compared to the conventional binary systems.

A Study on CCC(Capacitor Commutated Converter) and CSCC(Controlled Series Capacitor Converter) for HVDC System

  • Kim Chan-Ki;Kho Bong-Un;Lee Jong-Min;Chae Young-Mu
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.523-528
    • /
    • 2001
  • This paper deals with two non-conventional HVDC system, that are, the Capacitor Commutated Converter (CCC) in which series capacitors are included between the converter transformer and the valves, and the Controller Series Capacitor Converter (CSCC), based on more conventional topology, in which series capacitors are inserted between the AC filter bus and the AC network. The simulation waveforms show that if these compare to conventional HVDC, these HVDC systems have many advantages in steady-state and transient performance.

  • PDF

동심원형전극을 이용한 PZT 압전세라믹의 필터특 (Analysis of the Circuit System of a Theta Pinch)

  • Chung, Woon-Kwan;Kim, Shang-Hoon
    • 대한전기학회논문지
    • /
    • 제32권8호
    • /
    • pp.277-283
    • /
    • 1983
  • The pulse generating circuit system of the so-called turbulently-heated theta pinch is experimentally investigated, and its results are compared with the predictions based on the conventional theory. The conventional theory assumes that the impedance of the pinch coil is independent on the time rate of change in voltage (or current) across the pinch coil. The experimental pulse height of the voltage actross the pinch coil is about 1.5% fo that predicted by the conventional theory.

  • PDF

Uncertainty Assessment using Monte Carlo Simulation in Net Thrust Measurement at AETF

  • Lee, Bo-Hwa;Lee, Kyung-Jae;Yang, In-Young;Yang, Soo-Seok;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제8권2호
    • /
    • pp.126-131
    • /
    • 2007
  • In this paper, Monte Carlo Simulation (MCS) method was used as an uncertainty assessment tool for air flow, net thrust measurement. Uuncertainty sources of the net thrust measurement were analyzed, and the probability distribution characteristics of each source were discussed. Detailed MCS methodology was described including the effect of the number of simulation. Compared to the conventional sensitivity coefficient method, the MCS method has advantage in the uncertainty assessment. The MCS is comparatively simple, convenient and accurate, especially for complex or nonlinear measurement modeling equations. The uncertainty assessment result by MCS was compared with that of the conventional sensitivity coefficient method, and each method gave different result. The uncertainties in the net thrust measurement by the MCS and the conventional sensitivity coefficient method were 0.906% and 1.209%, respectively. It was concluded that the first order Taylor expansion in the conventional sensitivity coefficient method and the nonlinearity of model equation caused the difference. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the model equation of the measurement.

보강토 옹벽에서 연결시스템의 영향성 평가 (Evaluation of Effect for Connector System in Reinforced Earth Retaining Wall)

  • 이준대;허열;안광국;이용준
    • 한국안전학회지
    • /
    • 제21권4호
    • /
    • pp.85-94
    • /
    • 2006
  • In this study, in order to evaluate the effect of two types of connector systems in reinforced retaining wall, the centrifugal tests for the conventional connector and new settlement connector system were performed. In the centrifugal tests, the aluminum plate for the face was used and the aluminum foil was used as a reinforcement. The granite soil was adopted as a fill. As a result, The settlement reinforced retaining wall reached to the failure at 80g-level. In contrast, the conventional reinforced retaining wall was collapsed at 69g-level. It means that the settlement reinforced retaining wall has the stronger stability than the conventional reinforced retaining wall. In addition, it was shown that the settlement connector system is more effective to release the stress concentration occurred at the face of reinforced retaining wall than the conventional connector system.

Iterative V-BLAST Decoding Algorithm in the AMC System with a STD Scheme

  • Lee, Keun-Hong;Ryoo, Sang-Jin;Kim, Seo-Gyun;Hwang, In-Tae
    • Journal of information and communication convergence engineering
    • /
    • 제6권1호
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we propose and analyze the AMC (Adaptive Modulation and Coding) system with efficient turbo coded V-BLAST (Vertical-Bell-lab Layered Space-Time) technique. The proposed algorithm adopts extrinsic information from a MAP (Maximum A Posteriori) decoder with iterative decoding as a priori probability in two decoding procedures of V-BLAST scheme; the ordering and the slicing. Also, we consider the AMC system using the conventional turbo coded V-BLAST technique that simply combines the V-BLAST scheme with the turbo coding scheme. And we compare the proposed decoding algorithm to a conventional V-BLAST decoding algorithm and a ML (Maximum Likelihood) decoding algorithm. In addition, we apply a STD (Selection Transmit Diversity) scheme to the systems for better performance improvement. Results indicate that the proposed systems achieve better throughput performance than the conventional systems over the entire SNR range. In terms of transmission rate performance, the suggested system is close in proximity to the conventional system using the ML decoding algorithm.

Performance of DCSK under the Coexistence of non-Chaotic Transmit Reference System

  • ;곽경섭
    • 한국통신학회논문지
    • /
    • 제32권11A호
    • /
    • pp.1138-1145
    • /
    • 2007
  • In wireless communications, chaotic communications have been a field of interest due to its low complexity in hardware implementation and low power consumption in chaotic signal generation. Among the modulation schemes using the chaotic signal, Differential Chaos Shift Keying (DCSK) is a robust non coherent technique. As in the conventional communication systems, chaos-based systems are required to provide reasonable bit error performance in the presence of a narrow-band signal coming from any other systems. The frequency band of this foreign narrow band signal may lie within the bandwidth of the chaos-based systems. This situation may occur when chaotic signal transmission is done in the presence of other conventional communication system. This paper has evaluated the performance of the non coherent differential chaos shift keying (DCSK) system under the presence of conventional non-chaotic transmit reference system. Both systems are assumed to have same data rates. The mathematical expressions for the bit error rate (BER) are derived with computer simulations to verify the analytical results.

Design and Development of T-DMB Multichannel Audio Service System Based on Spatial Audio Coding

  • Lee, Yong-Ju;Seo, Jeong-Il;Beack, Seung-Kwon;Jang, Dae-Young;Kang, Kyeong-Ok;Kim, Jin-Woong;Hong, Jin-Woo
    • ETRI Journal
    • /
    • 제31권4호
    • /
    • pp.365-375
    • /
    • 2009
  • In this paper, a terrestrial digital multimedia broadcasting (T-DMB) multichannel audio broadcasting system based on spatial audio coding is presented. The proposed system provides realistic multichannel audio service via T-DMB with a small increase of data rate as well as backward compatibility with the conventional stereo-based T-DMB player. To reduce the data rate for additional multichannel audio signals, we compress the multichannel audio signals using the sound source location cue coding algorithm, which is an efficient parametric multichannel audio compression technique. For compatibility, we use the dependent property of an elementary stream descriptor, and this property should be ignored in a conventional T-DMB player. To verify the feasibility of the proposed system, we implement the T-DMB multichannel audio encoder and a prototype player. We perform a compatibility test using the T-DMB multichannel audio encoder and conventional T-DMB players. The test demonstrates that the proposed system is compatible with a conventional T-DMB player and that it can provide a promisingly rich audio service.

구동라인분리 센스앰프의 딜레이페일 개선 효과에 대한 분석 (Analysis of Improvement on Delay Failures in Separated Driving-line Sense Amplifier)

  • 김동영;김수연;박제원;김신욱;이명진
    • 전기전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.1-5
    • /
    • 2024
  • DRAM의 성능 개선을 위해 센스앰프의 미스매치로 인한 센싱페일을 감소시켜야 한다. 플립페일과 달리 딜레이페일은 고속 동작이 요구될 때 더 심화될 수 있어 차세대 메모리 설계 시 면밀히 고려되어야 할 문제이다. Conventional SA는 증폭 시작 시 모든 트랜지스터가 동시에 동작하는 반면, SDSA는 BLB를 출력으로 하는 트랜지스터 2개만 먼저 동작시켜 오프셋을 완화할 수 있다. 본 논문에서는 SDSA의 딜레이페일에 대한 우수성을 시뮬레이션을 통해 검증하였다. Conventional SA에 비해 약 90%의 딜레이 페일 감소 효과를 갖고 있음을 확인했다.