• 제목/요약/키워드: Conventional scan

검색결과 393건 처리시간 0.035초

VME bus를 이용한 Step & Scan형 노광장비의 Control System 구성 (VME bus based control system for step & scan exposure tool)

  • 최용만;오병주;김도훈;정해빈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.672-675
    • /
    • 1997
  • This paper proposes a structure of the control system for the step & scan exposure tool. The step & scan exposure tool is used for the manufacturing process of the semiconductor DRAM memory of giga bit. The control system employs the VME bus instead of the conventional ISA bus so that all control signals and data can be managed separately by the 4 VME-PCs for fast and fault-free flow of signals for multi-tasking. A high speed I/O card is equipped for the real-time monitoring and control of the sub module equipment. Then all the subsystems are integrated and aligned for the operation of the step & scan exposure tool with the VME bus and, I/O card.

  • PDF

적외선 센서를 이용한 열상장비의 구현 (Thermal Imager Implementation Using Infrared Sensor)

  • 유위경;윤은숙;김창우;송인섭;홍석민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

Effect of Scan-bias during Reset Period in a Negative Waveform

  • Park, W.H.;Lee, S.J.;Lee, J.Y.;Kang, J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.728-731
    • /
    • 2009
  • A negative waveform having inverted polarity of conventional waveform during reset and sustain periods was proposed to improve the driving characteristics. In order to control the negative wall-charge distribution, a positive bias on the scan electrode was applied during reset period. Compared to 0 V scan-bias condition, at 8 V scan-bias the formative time lag was improved about 23.95 % and the average time lag was improved about 14.91 %. All experiments were performed with the 42-inch PDP module in XGA resolution.

  • PDF

Mass Transport Properties and Influence of Natural Convection for Voltammetry at the Agarose Hydrogel Interface

  • Kim, Byung-Kwon;Park, Kyungsoon
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권3호
    • /
    • pp.347-353
    • /
    • 2022
  • Agarose hydrogel, a solid electrolyte, was investigated voltammetrically in terms of transport properties and natural convection effects using a ferrocenyl compound as a redox probe. To confirm the diffusion properties of solute on the agarose interface, the diffusion coefficients (D) of ferrocenemethanol in agarose hydrogel were determined by cyclic voltammetry (CV) according to the concentration of agarose hydrogel. While the value of D on the agarose interface is smaller than that in the bulk solution, the square root of the scan rate-dependent peak current reveals that the mass transport behavior of the solute on the agarose surface shows negligible convection or migration effects. In order to confirm the reduced natural convection on the gel interface, scan rate-dependent CV was performed in the solution phase and on the agarose surface, respectively. Slow scan voltammetry at the gel interface can determine a conventional and reproducible diffusion-controlled current down to a scan rate of 0.3 mV/s without any complicated equipment.

CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구 (COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION)

  • 정기훈;김은경;김상준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

ESI-MS/MS를 이용한 아실카르니틴과 아미노산의 정량분석 (Quantitative Analysis of Acylcarnitines and Amino Acids Using ESI-MS/MS)

  • 김호현;한상범;윤혜란
    • 분석과학
    • /
    • 제14권5호
    • /
    • pp.384-391
    • /
    • 2001
  • 본 연구에서는 ESI-MS/MS를 이용해 혈액내에서 아실카르니틴과 아미노산을 신속하게 정량분석하는 방법을 개발하였다. 아실카르니틴과 아미노산은 3N butanolic hydrogen chloride를 사용하여 유도체화 과정을 거친 뒤 이중질량분석기로 분석하였다. 아실카르니틴은 precursor 85 ion scan을 사용하여 분석하였고, 아미노산들중 알라닌, 발린, 루신/이소루신, 메티오닌, 페닐알라닌, 타이로신, 아스파르트산, 글루탐산 등은 neutral loss 102 scan, 오르니틴과 시트롤린은 neutral loss 119 scan, 글리신은 neutral loss 56 scan, 아르기닌은 neutral loss 161 scan 그리고 아르기니노석시닉산은 product ion 459 scan을 사용하여 분석하였다. 이 방법은 일반적인 액체 크로마토그래피나 아미노산 분석기에 비해서 시료의 전처리가 비교적 간단하며, 높은 감도와 좋은 재현성을 보여주었다.

  • PDF

악골 병소의 감별 진단시 골스캔의 임상적 유용성 (CLINICAL EFFECTIVENESS OF BONE SCAN FOR DIFFERENTIAL DIAGNOSIS OF JAW LESION)

  • 김정모;김철환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권1호
    • /
    • pp.33-41
    • /
    • 2007
  • Bone scan using radioactive isotope can be more effective than conventional X-ray radiograph for finding jaw lesion because it takes an image of the physiologic change of bone. This study is designed to show how available bone scan is able to diagnose jaw lesion better than simple X-ray and CT, as well as to determine a basis of diagnosis for jaw lesion using bone scan. The 77 patients, visiting the Oral & Maxillofacial Surgery, Department of Dankook University Hospital from January 2002. to August 2005. who were diagnosed histopathologically with postoperative malignant tumor, osteomyelitis, and bone infiltrative benign disease. Preoperative X-ray, CT, bone scan were taken and were compared with histopathologic finding. Also to compare specificty of each lesion in bone scan, bone density was measured to compare. The results were as follows. 1. Among the 25 cases of oral malignant tumor of bony invasion, a positive diagnosis associated with histopathologic evaluation, 22 cases(88%) in bone scan, 14 cases(56%) in CT image, and 10 cases40%) in simple X-ray. 2. Among the 31 cases of osteomyelitis, a positive diagnosis associated with histopathologic evaluation, 30 cases(97%) in bone scan, 23 cases(74%) in CT image, and 19 cases(61%) in simple X-ray. 3. Among the 11cases of bone infiltrative benign disease, a positive diagnosis associated with histopathologic evaluation, 11 cases(100%) in bone scan, 10 cases(91%) in CT image, and 6 cases(55%) in simple X-ray. 4. Measurement of bone density in each group showed no statistical significant difference between malignant tumor and osteomyelitis as well as benign bone disease. But, a statistical significance was seen between osteomyelitis and benign bone disease. From this results, bone scan are more sensitive than simple X-ray and CT image in jaw lesion diagnosis, but specificity shows no significant difference. Therefore, it should be suggested that evaluation of bone scan must be carrying out in reference to final histopathologic diagnosis.

Low Cost Driving System for Plasma Display Panels by Eliminating Path Switches and Merging Power Switches

  • Lee, Dong-Myung;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.278-285
    • /
    • 2007
  • Recently, plasma display panels (PDP) have become the most promising candidate in the market for large screen size flat panel displays. PDPs have many merits such as a fast display response time and wide viewing angle. However, there are still concerns about high cost because they require complex driving circuits composed of high power switching devices to generate various voltage waveforms for three operational modes of reset, scan, and sustain. Conventional PDP driving circuits use path switches for voltage separation and a scan switch to offer a scan voltage for reset and scan operations, respectively. In addition, there exist reset switches to initialize PDPs by regulating the wall charge conditions with ramp shaped pulses, which means the necessity of specific power devices for the reset operation. Because power for the plasma discharge accompanied by a large current is transferred to a panel via path switches, high power rating switches are used for path switches. Therefore, this paper proposes a novel low-cost PDP driving scheme achieved by not only eliminating path switches but also merging the function of reset switches into other switches used for sustain or scan operations. The simulated voltage waveforms of the proposed topology and experimental results implemented in a 42-inch panel to demonstrate the validity of using a new gate driver that merges the functions of power switches are presented.

Performance testing of a FastScan whole body counter using an artificial neural network

  • Cho, Moonhyung;Weon, Yuho;Jung, Taekmin
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3043-3050
    • /
    • 2022
  • In Korea, all nuclear power plants (NPPs) participate in annual performance tests including in vivo measurements using the FastScan, a stand type whole body counter (WBC), manufactured by Canberra. In 2018, all Korean NPPs satisfied the testing criterion, the root mean square error (RMSE) ≤ 0.25, for the whole body configuration, but three NPPs which participated in an additional lung configuration test in the fission and activation product category did not meet the criterion. Due to the low resolution of the FastScan NaI(Tl) detectors, the conventional peak analysis (PA) method of the FastScan did not show sufficient performance to meet the criterion in the presence of interfering radioisotopes (RIs), 134Cs and 137Cs. In this study, we developed an artificial neural network (ANN) to improve the performance of the FastScan in the lung configuration. All of the RMSE values derived by the ANN satisfied the criterion, even though the photopeaks of 134Cs and 137Cs interfered with those of the analytes or the analyte photopeaks were located in a low-energy region below 300 keV. Since the ANN performed better than the PA method, it would be expected to be a promising approach to improve the accuracy and precision of in vivo FastScan measurement for the lung configuration.

초음파 섹터 B-스캐너의 개발(II)-디지탈 스캔 컨버터- (Development of Ultrasound Sector B-Scanner(II)-Digital Scan Converter-)

  • 김주한;김영모
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.133-138
    • /
    • 1986
  • Abstract In a conventional digital sector scan system in the ultrasound medical imaging, the sampling space is in the polar coordinates while the display space is in the cartesian coordinates, which necessitates a coordinate transformation process resultion process resulting the overall system very complex and bulky. In this paper we propose a new architecture of the Digital-Scan-Converter (DSC) for the ultrasound sector scan system in which sampling space is the same as the display space, so the data are displayed as they are acquired without any interpola- tion process required. To implement the above real time DSC. two frequency synthesizes with very high switching time and a low-pass filter are required. The former determines the precise location of the data points and the latter fills the gap betw- een pixels in the horizontal direction.

  • PDF