• Title/Summary/Keyword: Control sampling period

Search Result 264, Processing Time 0.033 seconds

Derivation of the Timing Constraints for Multi-Sampled Multitasks in a Real-Time Control System (다중샘플링 다중작업을 수행하는 실시간제어시스템의 시계수제한성 유도)

  • 이대현;김학배
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.145-150
    • /
    • 1999
  • A real-time control system, composed of the controlled processor and the controller computer(s), may have a variety of task types, some of which have tight timing-constraints in generating the correct control input. The maximum period of those task failures tolerable by the system is called the hard deadline, which depends on not only fault characteristics but also task characteristics. In the paper, we extend a method deriving the hard deadline in LTI system executing single task. An algorithm to combine the deadlines of all the elementary tasks in the same operation-mode is proposed to derive the hard deadline of the entire system. For the end, we modify the state equation for the task to capture the effects of task failures (delays in producing correct values) and inter-correlation. We also classify the type of executing the tasks according to operation modes associated with relative importance of correlated levels among tasks, into series, parallel, and cascade modes. Some examples are presented to demonstrate the effectiveness of the proposed methods.

  • PDF

Characteristics of a Sliding Mode Controller with Disturbance Estimator (외란 추정기를 갖는 슬라이딩 모드 제어기의 특성)

  • Choe, Seung-Bok;Ham, Jun-Ho;Park, Jong-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.165-171
    • /
    • 2002
  • The conventional sliding mode control(SMC) technique requires a priori knowledge of the upperbounds of disturbances or/and modeling uncertainties to assure robustness. This, however, may not to be easy to obtain in practical situation. This paper presents a new methodology, sliding mode control with disturbance estimator(SMCDE), which offers a robust control performance without a priori knowledge about the disturbance. The proposed technique is featured by an average value of the imposed disturbance over a certain period. A nonlinear spring-mass-damper system is adopted as an illustrative example, and a comparative work between the conventional technique and the present one is undertaken.

COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

A Case Study on the Work Measurement of Hospital Foodservice by the Work Sampling Methodology (워크샘플링(Work Sampling)에 의한 병원급식의 작업측정 사례연구)

  • 차진아
    • Journal of Nutrition and Health
    • /
    • v.24 no.6
    • /
    • pp.547-559
    • /
    • 1991
  • The purposes of this study were to : a)determine the percentage of labor activities expen-ded in various work functionsof hospital foodservice b)estimate the labor time utilized in each work functions c)investigate the overall work patterns of hospital foodservice and d)provide the basic data for effective labor control This study was conducted in two hospitals with 1300 and 1200 ed capacities and every employees of the dietary department were included in 10days work measurement. Work sampling methodology developed by Donaldson and Ostenso was modified and used for observing overall activities of hospital dietary department. Consistency of data and observa-tion period were verified by 3$\delta$ control chart and control chart. Observed data were satisfied with confidence level of 95% and confidence interval of $\pm$0.05, The results of this study were as follows: 1) The direct work function indirect work function and delay were 74.8%, 9.2%, 16.0% respectively with A hospital and 82.2% 7.2%, 10.6% respectively with B hospital 2) The productivity indices of direct work indirect work and delay were 9.05 min/meal 1.12 min/meal 1.94 min/meal respectively and total 12.11 minutes were utilized per meal served in A hospital and 10.72 min/meal 0.94 min/meal 1.38 min/meal respectively and total 13.04 minutes were utilized per meal served in B hospital 3) Full time equivalent(FTE) utilized in daily work of irect work indirect work and delay were 62.24 men 7.69 men 13.35 men respectively in A hospital and 64.09 men 5.63 men 8.22 men respectively in B hospital. 4) The contents of work activities of each employee group showed that delay time of the service personnel group was more than any other employee groups in both A hospital and B hospital 5) Examination of daily work schedule by time intervals showed that transportation work function was carried out all day so it is necessary to improve this work.

  • PDF

Suppression of Zero Sequence Current Caused by Dead-time for Dual Inverter With Single Source (단전원 듀얼 인버터의 데드타임으로 인한 영상전류 억제 방법)

  • Yoon, Bum-Ryeol;Kim, Tae-Hyeong;Lee, June-Hee;Lee, June-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.126-133
    • /
    • 2022
  • This study proposes a suppression of zero sequence current (ZSC), which is caused by zero sequence voltage (ZSV) for a dual two-level inverter with single DC bus. Large output voltages enable the dual inverter with single DC bus to improve a system efficiency compared with single inverter. However, the structure of dual inverter with single DC bus inevitably generates ZSC, which reduces the system efficiency and causes a current ripple. ZSV is also produced by dead time, and its magnitude is determined by the DC bus and current direction. This study presents a novel space vector modulation method that allows the instantaneous suppression of ZSC. Based on a condition where a switching period is twice a sampling (control) period, the proposed control method is implemented by injecting the offset voltage at the primary inverter. This offset voltage is injected in half of the switching period to suppress the ZSC. Simulation and experiments are used to compare the proposed and conventional methods to determine the ZSC suppression performance.

Digital Redesign using the Discrete Grammian Method (연속제어기의 GSHF(Generalized Sampled-data Hold Function)을 이용한 디지탈 재설계시의 이산적 GRAMMIAN 행렬의 사용)

  • Chung, Chi-B.;Chung, Tae-S.;Yang, Won-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.306-309
    • /
    • 1993
  • Digital redesign techniques are to derive a digital controller fred the existing continuous controller and its plant so that the performance of the digitally controlled system is matched as closely as possible to that of the original continuous system at the sampling instants. Recently a new digital redesign technique, was developed to use the generalized sampled-data hold function(GSHF) based on the the grammian matrix. With this new technique the digitally redesigned system showed several good features compared with any existing technique in terms of the state match at the sampling instants, the large sampling period, and the transient reponses. This paper concerns a further improvement of the new digital redesign technique by employing the discrete grammian matrix instead of the continuous grammian matrix in defining GSHF. With this modification, it was observed by simulation that the transient response of the modified digital system shows far better performance than the digital system based on the continuous grammian matrix.

  • PDF

Tip Position Control of Flexible Manipulator Using Disturbance Estimator (외란 추정기를 이용한 유연 매니퓰레이터의 선단 위치제어)

  • 김상열;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.219-224
    • /
    • 2001
  • An accurate tip position control of a single-link flexible manipulator subjected to torque disturbance is achieved by utilizing so called sliding mode controller with disturbance estimation (SMCDE). After formulating the governing equation of motion in the state 1pace representation, a stable sliding surface is designed via the LQR method. The SMCDE is then synthesized by integrating equivalent sliding mode controller with the disturbance estimator which is featured by an integrated average value of the imposed disturbance over a certain sampling period. The regulating tip motion of the flexible manipulator is evaluated by employing the proposed SMCDE.

  • PDF

Sensorless Control Strategy of IPMSM Based on a Parallel Reduced-Order EKF (병렬형 저감 차수 칼만 필터를 이용한 IPMSM의 센서리스 제어)

  • Yim, Dong-Hoon;Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.448-449
    • /
    • 2010
  • This paper proposes a sensorless control strategy for the Interior Permanent Magnet Synchronous Motor (IPMSM) by using the parallel reduced-order Extended Kalman Filter. The sensorless control strategy is composed with two EKFs alternately computed every sampling period with a new model. The new model is based on the extended electromotive force (EEMF) which has a simple structure, making position estimation possible without approximation. The proposed strategy can save computation time and estimate rotor speed and position. To verify the merit of the proposed strategy, simulation and experimental results validate the theoretical analysis and show the feasibility of the proposed control strategy.

  • PDF

The Parallel Operation of AC to DC PWM Converters for a High Speed Railway Train (고속전철용 입력 AC/DC PWM 컨버터의 병령운전)

  • Ryu, Hong-Je;U, Myeong-Ho;Kim, Jong-Su;Im, Geun-Hui;Won, Chung-Yeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.4
    • /
    • pp.272-281
    • /
    • 2000
  • This paper deals with the parallel operation of several numbers of PWM converters for a high speed railway train application. Several considerations are made to reduce the transformer interaction which can cause a current control problem in severe case. Also, in this paper, novel control strategy is proposed to achieve a harmonic free primary-side current control under a light load condition using one current sensor independent of the number of converters. In addition, the modified predictive current controller, which is suitable to a digital current controller with a relatively large sampling period, is used. Finally, to verify the system validity, digital control system with TMS320C44 micro-processor and small scale simulator are made and tested.

  • PDF

A Model Predictive Control Method to Reduce Common-Mode Voltage for Voltage Source Inverters

  • Vu, Huu-Cong;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.209-210
    • /
    • 2015
  • This paper presents a new model predictive control method without the effect of a weighting factor in order to reduce common-mode voltage (CMV) for a three-phase voltage source inverter (VSI). By utilizing two active states with same dwell time during a sampling period instead of one state used in conventional method, the proposed method can reduce the CMV of VSI without the weighting factor. Simulation is carried out to verify the effectiveness of the proposed predictive control method with the aid of PSIM software.

  • PDF