Simulation of a Clean Room Fire II. Needs of Smoke Control System and Springkler System (청정실 화재의 시뮬레이션 II. 제연설비와 스프링클러설비의 필요성)

  • Park, Woe-Chul;Lee, Man-Geun;Park, Hun-Sik
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.8-13
    • /
    • 2006
  • Numerical simulations were carried out for a fire in a clean room to confirm needs of a smoke control system and a sprinkler system, and to investigate a possible smoke spread-out. For a 1 MW methanol fire in a space of $39m{\times}13m$ floor and 4 m high, smoke spread-out was scrutinized for failure of the sprinkler system and/or the smoke control system. It was shown that the smoke control system removes smoke safely without the sprinkler system and that the sprinkler system is required to suppress smoke generation and spread of the fire, and to remove the smoke quickly. It was also confirmed that highly reliable sprinkler heads and automatic fire detection system are required for the sprinkler and smoke control systems.

A Suggestion of Sizing System for Clean Room Wear (무진복의 치수체계에 대한 연구)

  • 이경화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1044-1055
    • /
    • 2000
  • The purpose of this study is to suggest sizing chart for a clean room wear. 3 control dimensions(Stature, Bust girth, B.N.P.∼Wrist point length) were chosen as 3 axes of clean room wear size chart. A loss function was used to determined intervals of stature, Bust girth and B.N.P.∼Wrist point length of size chart, because the loss function introduces the concept of frequency to size chart for better customer's size satisfaction. From the size table whose intervals had been determined by a loss function. The 4 sizes individually were suggested for clean room wear size chart by sex. The 3 sizes individually were suggested for clean room head cover size chart by sex too. The suggested size chart would be considered more feasible than present size chart. Also they are suggested supply reference measurement chart relevant to clean room wear manufacturing for 13 most frequent sizes.

  • PDF

A Ventilation Control Model System of Standby Generating Room Installed in Basement of Building (건물 지하층에 설치된 자가발전기실의 환기제어 모델 시스템에 관한 연구)

  • 홍원표;강병권
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents a new ventilation control model system of standby generating room installed in basement of building. The regulation problem & current status of ventilation system considered the architectural construction and building service facility procedure are also investigated. The regulation solution, ventilation control model system and its theoretical analysis for room of the generating system by driven diesel are proposed from the analyzed results of survey.

  • PDF

Environment Design for Digitalized Main Control Room in Nuclear Power Plant

  • Cha, Woo Chang
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • The purpose of the Environment Design (ED) for Main Control Room (MCR) of Nuclear Power Plant (NPP) is to provide and create an optimal working space to be free from physical, physiological and mental stress as well as environmental discomfort, based on the previous environment design experiences and to recommend the best ED including the color, the lighting and the interior design. Environment Design consists of three main areas: Human factor engineering design, Interior design with color design, and Lighting design. These design areas have been interactively cooperated in a way that each design specialist would share the objectives and concepts of the Environment Design for MCR. The specialists for Human Factors Engineering design had a corporative role in such a way to provide the guidelines for MCR design suitability of Interior and Lighting design considering the Human System Interface (HSI) safety concerns. This paper describes fruitful efforts to create the best fit for MCR ED among several design proposals with the design recommendations, impacts, and contributions to NPP environment.

Implementation of Fuzzy Logic Control for Air Conditioning Systems

  • Mongkolwongrojn, M.;Sarawit, V.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1264-1267
    • /
    • 2005
  • Fuzzy logic control has been widely applied for handling the system which has uncertainty or high robust system. Since the dynamic behaviors of the systems contain complexity and uncertainty in its parameters, several fuzzy logic controllers have been implemented to control room temperature in the field of air conditioning system. In this paper, the fuzzy logic control has been developed to control both in door temperature and humidity in the air conditioning systems. The manipulating variables are speed of compressor, heater and supply air flow rate. The microcomputer was used to interface with in system. The experimental results show the superior of multivaiable fuzzy logic control to keep room temperature and humidity in air conditioning system for the best comfortable.

  • PDF

Fault Tolerant Design of Universal Soft Controller for Advanced Power Reactor (신형원전(APR+)을 위한 범용소프트제어기의 내고장성 설계)

  • Ye, Song-Hae;Lyou, Joon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.279-286
    • /
    • 2012
  • Recently, design of Universal Soft Controller(USC) has been applied to the advanced control room for nuclear power plant. USC is software-based manual control means to control safety components as well as non-safety components in the highly-integrated control room. Therefore, design feature of USC is essential for the implementation of a single workstation in the advanced control room. The traditional control room is replaced by computer-driven consolidated operator interfaces. Considering our design has further reduced the probability of USC spurious signals by requiring two distinct operator control actions to generate any control signal. The reality of USC does not increase the probability of reactor trip because the probability of spurious USC signal is negligible. Universal Soft Control represents a significant evolution in nuclear I&C/HSI System. USC integrates the indicators and controls from multiple divisions into a single integrated visual display unit(VDU) based HSI(Human System Interface). In order to prevent adverse influence on safety function performance from USC failure, ESFAS signals are applied to safety components or functions. In addition, safety manual switches have priority over USC's signals. Therefore, spurious USC signals can be momentarily blocked by selecting a soft control command from the safety VDU.

A Teleoperated Cleaning Robot for a High Radioactive Environment

  • Kim, Ki-Ho;Park, Jang-Jin;Yang, Myung-Seung;Oh, Chae-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.849-854
    • /
    • 2003
  • The Korea Atomic Energy Research Institute has developed a teleoperated cleaning robot for use in the radioactive zone of the isolation room of the Irradiated Material Examination Facility where direct human access to the interior is strictly limited. The teleoperated cleaning robot that was designed to completely eliminate human interaction with the hazardous radioactive contaminants has five remotely replaceable submodules - a mobile module for navigation, a cleaning module for dislodging and sucking contaminated waste, a sensing module for obstacle avoidance, a collection module for storing the acquired waste, and a cover module for protecting the collection module. This cleaning robot is capable of cleaning the contaminated floor surface of the isolation room and collecting loose dry spent nuclear fuel debris and other radioactive waste fixed or scattered on the floor surface. The developed cleaning robot is operated either by a manual control or by autonomous control in conjunction with a graphical simulator, by which the human operator can monitor and intervene the robot performing cleanup tasks in the isolation room. In this paper, we present the mechanical and environmental design considerations and development of the teleoperated cleaning robot for radioactive isolation room use. We also demonstrate its mock-up performance test results from the viewpoint of a remote cleanup operation and remote maintenance.

  • PDF

Numerical Analysis on Energy Reduction of an Exhaust-Air-Heat-Recovery Type Air Washer System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 에어와셔 시스템의 에너지절감에 관한 수치해석)

  • Song, Gen-Soo;Kim, Hyung-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.697-703
    • /
    • 2010
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants from the outdoor air introduced into a clean room. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery is useful for reducing the outdoor air conditioning load required to maintain a clean room. Therefore it is desirable to recover heat from the exhaust air and use it to cool or heat the outdoor air. In the present study, numerical analysis was conducted to evaluate the recovered heat of an exhaust air heat recovery type air washer system, which is the key part of an energy saving outdoor air conditioning system for semiconductor clean rooms. The present numerical results showed relatively good agreement with the available experimental data.

Development of integrated test facility for human factors experiments in nuclear power plant (원자력발전소에서의 인간공학적 실험평가를 위한 종합 실험설비 개발)

  • 오인석;이현철;천세우;박근옥;심봉식
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.107-117
    • /
    • 1997
  • It is necessary to evaluate HMI inaspects of human factors in the design stage of MMIS(man machine interface system) and feedback the result of evaluation because operators performance is mainly influenced by the HMI. Therefore, the MMIS design should be reflected the operators psychological, behavioral and physiological characteristics in the interaction with human machine interface(HMI) in order to improve the safety and availability of the MMIS of a nuclear power plant(NPP) by reduction of human error. The development of human factors experimental evaluation techniques and integrated test facility(ITF) for the human factors evaluation become an important research field to resolve hi,am factors issues on the design of an advanced control room(ACR). We developed am ITF, which is aimed to experiment with the design of the ACR and the human machine interaction as it relates to the control of NPP. This paper presents the development of an ITF that consists of three rooms such as main test room(MTR), supporting test room(STR) and experiment control room(ECR). And, the ITF has a various facilities such as a human machine simulator(HMS), experimental measurement systems and data analysis and experiment evaluation supporting system(DAEXESS). The HMS consists of full-scope simulation model of Korean standard NPP and advanced HMI based on visual display nits (VDUS) such as touch color CRT, large scale display panel(LSDP), flat panel display unit and so on.

  • PDF

A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - Results Influenced by the Choice of a Criterion Function - (슬래브축열의 최적제어방책에 관한 연구 -평가함수의 선택이 결과에 미치는 영향-)

  • Jung, Jae-Hoon;Shin, Young-Gy
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.896-905
    • /
    • 2006
  • An optimal control of an air-conditioning system with slab thermal storage is investigated by making use of the Maximum Principle. An optimal heat input to a plenum chamber and an air-conditioned room is determined by minimizing a criterion function which is given as integral sum of two terms. The first term is the square of the deviation in the room air temperature from the set-point value, and the second is the absolute value of the heat input. The result indicates that it tries to keep a room air temperature in set-point value by heating as much as possible at the time of a setup of a room air temperature or just before that, in order to avoid a heat loss arising at the time of the non-air conditioning. The result is compared with that of the case when the square of the heat input is used as a criterion.