• 제목/요약/키워드: Control malfunction

검색결과 238건 처리시간 0.025초

항공기 시뮬레이터 조종력 제어시스템의 견실 $\mu$-제어기 설계 (Robust $\mu$-Controller design for Control Loading System of Flight Simulator)

  • 방경호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.405-408
    • /
    • 1998
  • Generally, the principle function of simulator control loading system is to provide the pilot or student with the "feel" of the actual aircraft flight control systems during flight, taxing, and in malfunction. Flight control "feel" is the resistance felt by the pilot when moving a control stick or pedal, coupled with the amount of control surface deflection, and hence aircraft response, resulting from the input. Therefore, the control loading servo must be capable of performing to some general list of requirements derived from real aircraft control forces. In this paper, we deal with a $\mu-controller$ design for a control loading system of the flight simulator. For this, we derive a frequency response of the hydraulic system from the identification data and then design a controller using a $\mu-synthesis$ method. Under the same condition of simulation, $\mu-controller$ provides the superior performance than PID controller.than PID controller.

  • PDF

보의 진동억제를 위한 중앙화 및 비중앙화 제어의 비교 연구 (Comparison of Centralized and Decentralized Control for Vibration Suppression of a Beam)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.494-497
    • /
    • 2005
  • Direct velocity feedback (DVFB) control with a collocated distributed actuator and point sensor pair is known that it offers a good stability with high performance when the control strategy is applied at the suppression of structural vibration. Also decentralized control method introduced to offer to reduce implementaion effort and malfunction due to failure in sensors and actuators of control system has become an important position in DVFB. In this paper, the decentralized control is compared with centralized control in terms of vibrational velocity reduction in a clamped-clamped beam.

  • PDF

근접센서의 고온 고장발생에 관한 원인분석 및 개선 연구 (A Study On Cause Analysis and Improvement About Malfunction of Proximity Sensor Exposed High Temperature)

  • 박진생
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권3호
    • /
    • pp.175-181
    • /
    • 2015
  • 전투차량의 내부는 혹서기에는 약 $80^{\circ}C$에 이를 만큼 고온 다습한 환경에 노출되어 감지거리를 측정하여 제어기에 신호를 전달하는 근접센서가 감지거리가 늘어나면서 결국에는 센서 자체의 금속물질을 인식하여 작동이 안되는 고장이 다발하여 원인분석 및 개선을 수행하게 되었다. 개선은 2차에 걸쳐 수행되었고 많은 시행착오를 거쳐 고온에 장기적으로 노출될 경우 고장이 발생된다는 것을 알아내어 개선방안을 도출한 결과, 이미터코일(Emitter Coil)을 한 개 더 추가하여 전압차이를 높여 감지 정확도를 향상시키고, 내부 몰딩 면적을 높여 진동 및 충격 내성을 강화하여 온도 및 습도 변화에 둔감하도록 설계개선을 하였다. 입증을 위해 고온 다습($85^{\circ}C$, 85%습도)한 환경챔버에서 136시간 내구시험을 실시하여 고장 발생이 없음을 확인하였다.

LPG 자동차에서 전자제어엔진용 센서의 고장사례에 관한 연구 (Failure Case Studies of Sensors for Electronic Controlled Engine in LPG Vehicle)

  • 김청균;이일권
    • 한국가스학회지
    • /
    • 제14권4호
    • /
    • pp.56-62
    • /
    • 2010
  • 본 논문은 LPG 엔진의 전자제어센서에 대한 고장사례를 분석하고 고찰한 연구이다. LP가스의 연료 분사량을 컨트롤하는 크랭크 각도센서의 기능이상은 불규칙하고 불균일한 파형형태로 나타나고 있다. 크랭크 각도센서의 노이즈에 관련된 파형은 톱니형의 불규칙한 피크형상으로 나타났고, 2.46V 정도의 노이즈 레벨이 간헐적으로 발생하고 있다. 1번 TDC센서의 내부불량으로 인해 발생한 고장사례는 엔진의 출력을 떨어뜨리고 시동을 간헐적으로 꺼지게 하는 문제점을 초래한다. 산소센서의 성능이상은 센서의 배선에서 연결이 단절되었기 때문에 발생한 것으로 차량의 울컥거리는 현상과 엔진의 부조화 현상이 나타나고 있다. 에어 크리너를 이종품으로 사용한 경우는 신기가 정상적으로 공급되지 못했기 때문에 차량의 가속불량과 엔진의 부조화 현상이 발생하는 원인으로 작용하고 있었다.

신경회로망을 이용한 플라즈마 식각공정의 최적운영과 이상검출에 관한 연구 (A Study on The Optimal Operation and Malfunction Detection of Plasma Etching Utilizing Neural Network)

  • 고택범;차상엽;이석주;최순혁;우광방
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.433-440
    • /
    • 1998
  • The purpose of this study is to provide an integrated process control system for plasma etching. The control system is designed to employ neural network for the modeling of plasma etching process and to utilize genetic algorithm to search for the appropriate selection of control input variables, and to provide a control chart to maintain the process output within a desired range in the real plasma etching process. The target equipment is the one operating in DRAM production lines. The result shows that the integrated system developed is practical value in the improved performance of plasma etching process.

  • PDF

이중구조를 갖는 제어시스템의 구현과 신뢰도 분석에 관한 연구 (A Study on the Implementation of a Control System with Dual Structure and Its Reliability Analysis)

  • 박세화;문봉채;김병국
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1351-1363
    • /
    • 1990
  • In this paper, a reliable control system structured with dual CPU modules and dual I/O modules is implemented as a means of achieving a highly reliable fault tolerant control system. For this, faults in the system modules are first examined, and a fault detection technique consisting of self diagnostic, comparison process, and exception processing is applied. Self diagnostic is used to locate which components in the modules have been failed, while comparison process is to cmpare control outputs computed by both CPU modules and protect the plant from malfunction by blocking failed control outputsin advance. Finally exception processing is used to determine the faults that are not detected immediately by the self diagnostic and comparison process, e.g. bus error processing when acknowledge signal for data transfer is not activeted in the I/O modules. Also reliability analysis is conducted for the discrete time Markov model with dual structure. It is shown quantitatively that the reliability is improved in the control system with dual structure in comparison with a system with single module structure.

  • PDF

발전소 전자제어설비 환경시험에 관한 고찰 (An investigation of environmental tests for electric control system in power plants)

  • 정창기;이주현;류흥우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.550-554
    • /
    • 1997
  • It is important to select a reliable electronic control system in power plants because a trip of a power plant caused by malfunction of the control system can lead to a great deal of economic and social loss. In this paper. environmental test specifications for evaluating the reliability of the electronic control system were developed in order to select a reliable one. Also, the electronic control systems made by domestic manufacturers were tested based on these developed environmental test specifications.

  • PDF

극저온 환경에서의 정 출력 제어를 적용한 마이크로터빈의 새로운 시동 로직 개발 (New Start-Up Logic for Microturbine by Constant Power Control under an Extremely Low Temperature)

  • 노민식
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1249-1255
    • /
    • 2006
  • This paper presents a constant power control logic for perfect starting a microtubine in vehicle. Under extremely low temperature, performance of the start-up system is severely dropped than that of room temperature because of increasing of load of mechanical parts including engine core and drop of the lead-acid battery capacity. Unfortunately, performance drop of lead-acid battery makes severe problems that cause a malfunction of fuel and lubrication system and power fail of digital devices. So we propose the new start-up logic by constant output power control of lead-acid battery using PWM inverter controller for preventing above problems and keeping good performance of start-up system for microturbine. Also, we prove usefulness of new start-up logic through experimental results under $-32^{\circ}C$ ambient temperature.

다중 백업 기능 제어기를 갖는 네트워크형 분산 제어 (Network Type Distributed Control with Multi-Backup Function Controller)

  • 최군호
    • 반도체디스플레이기술학회지
    • /
    • 제13권4호
    • /
    • pp.37-42
    • /
    • 2014
  • Stable running is a very important factor when we are building a control system. But, sometimes malfunction of the system controller is caused by several reasons. To solve these problems, some systems have prepared a backup controller. In the generality of cases, making a backup controller is no easy work. Especially, it becomes more difficult when many backup controllers have to be embodied in one system. In this paper, the multi-backup function controller which was implemented in the form of the network type distributed control system will be suggested. Also, using Arago Disk System that has a structure for inner loop control, the validity of the proposed methods will be verified.

엔진 문전 조건이 촉매 온도에 미치는 영향 (Parametric Study of Engine Operating Conditions Affecting on Catalytic Converter Temperature)

  • 이석환;배충식;이용표;한태식
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.61-69
    • /
    • 2002
  • To meet stringent LEV and ULEV emission standards, a considerable amount of development work was necessary to ensure suitable efficiency and durability of catalyst systems. The main challenge is to cut off the engine cold-start emissions. It is known that up to 80% of the total hydrocarbons(THC) are exhausted within the first five minutes in case of US FTP 75 cycle. Close-Coupled Catalyst(CCC) provides fast light-off temperature by utilizing the energy in the exhaust gas. However, if some malfunction occurred at engine operation and the catalyst temperature exceeds 1050$\^{C}$, the catalytic converter is deactivated and shows the poor conversion efficiency. This paper presents effEcts of engine operating conditions on catalytic converter temperature in a SI engine, which are the indications of catalytic deactivation. Exhaust gas temperature and catalyst temperature were measured as a function of air/fuel ratio, ignition timing and misfire rates. Additionally, light-off time was measured to investigate the effect of operating conditions. It was found that ignition retard and misfire can result in the deactivation of the catalytic converter, which eventually leads the drastic thermal aging of the converter. Significant reduction in light-off time can be achieved with proper control of ignition retard and misfire, which can reduce cold-start HC emissions as well.